Webasto Air Top Evo 3900, Air Top Evo 5500 Operating Instructions

Page 1
1. The Air Top Evo 3900 / Air Top Evo 5500
heaters have been type-tested and approved in accordance with Directives ECE R10 and 72/245/EEC (EMC) and ECE R122 and 2001/56/EC (heater) with the following EC permit numbers:
e1*72/245*2006/96*5529 (Air Top Evo 3900 / 5500) E1 03 5529 (Air Top Evo 3900 / 5500)
NOTE: The specifications of this Directives are binding in the scope of the basic Directives EEC/70/156 and/or EC/2007/46 (for new vehicle models from 29/04/
2009) and should also be observed in countries in which no special regulations exist.
2. The year in which the heater was used for the first time must be permanently displayed on the factory plate by deleting the inapplicable years from the plate.
3. The heaters are not designed for heating hazardous substance transport compartments.
4. Claims can only be made if it can be verified that the claimant has complied with the servicing and safety instructions.
5. The heater must be switched off at filling stations and tank farms as a result of the risk of explosion.
6. The heater may not be operated in enclosed spaces (such as garages) as a result of the risk of poisoning and asphyxiation, even if a timer or Telestart remote is used.
7. The heater must be checked by an expert at the latest at the start of the cold weather period.
8. In the event of long-lasting heavy smoke development, unusual combustion noises or a smell of fuel or if the heater suffers continuous fault cut-outs with error messages (flashing code), it must be shut down by removing the fuse and must not be reused until it has been inspected by Webasto-trained personnel.
9. Wherever inflammable vapours or dust may form (for example in the vicinity of fuel, carbon, wood dust or cereal stores or the like), the heater must be switched off as a result of the risk of explosion.
Servicing and safety instructions
Operating Instructions Air Top Evo 3900 Air Top Evo 5500
Webasto Product North America
15083 North Rd. Fenton, MI 48430 Tel: 810-593-6000 - http://www.techwebasto.com
Page 2
10. The heat transfer unit on air heaters is exposed to very high thermal stress and must be replaced by a genuine Webasto spare part ten years after it is used for the first time.
If exhaust lines pass through areas used by personnel, they must also be replaced by genuine spare parts after ten years.
11. The diesel fuel specified by the vessel manufacturer is suitable for use in the Air Top Evo 3900 D/Air Top Evo 5500 D. Class EL heating oil (not L heating oil) may also be used as long as it complies to the normal quality available on the German market pursuant to DIN 51603.
The Air Top Evo 3900 D/Air Top Evo 5500 D heaters are also licensed for use with PME (bio-diesel), which complies with DIN EN 14214.
We know of no negative influences due to additives.
If fuel is extracted from the vessels tank, follow the additive instructions issued by the vehicle manufacturer.
If you change to low-temperature fuel, the heater must be operated for approx. 15 minutes so that the fuel system is filled with the new fuel.
12. The temperature in the area around the heater unit must not exceed 85 °C (storage temperature). If the temperature exceeds this level there is a risk of permanent damage to the electronics systems.
13. Non-compliance with the installation instructions and the warnings contained therein will lead to the exclusion of all liability by Webasto. The same applies if repairs are carried out incorrectly or with the use of parts other than genuine spare parts. This will result in the invalidation of the type approval for the heater unit, and therefore of its homologation/ EC type licence.
14. Keep the hot air inlet and hot air outlet free of dirt and foreign bodies. Soiled or blocked hot air lines may cause overheating, and therefore result in the overheating cut-out tripping.
15. To prevent mechanical parts seizing, the heater should be operated for approx. 10 minutes every four weeks.
16. Do not stand on the heater and do not place any heavy items on the heater or throw items at the heater.
17. Do not place any items of clothing, textiles or similar materials over the heater or in front of the hot air inlet and the hot air outlet.
18. The current of hot air in the heater must not be restricted or blocked by highly inflammable substances or materials such as rags, cleaning wool, etc.
19. The heater must not be cleaned with a high pressure cleaner.
Servicing and safety instructions
Page 3
Control Panel Air Top Evo MC04
General information
Using the Control Panel Air Top EVO MC04, The Air Top Evo heaters show their full functionality with the new user interface Air Top Evo M.
The control panel is to switch on/off, as well as to preselect the operation modes and the interior temperature. For technical data as well as references to the installation, see the installation instructions of the specific heater.
PLUS Heating Mode
Ventilation Mode
Comfort Zone
20...25°C (68...77°F)
Temp. selection in heating mode
Fan speed selection in ventilation mode
Operating / Failure Code LED
ON / OFF Switch
Product Name:
Air Top EVO M
(M = Marine)
ECO Heating Mode
Normal Heating Mode
Page 4
Operation
Main switch ON / OFF
Switching on the heater
By pressing the main switch ON / OFF the heater is activated. After switching on, the main switch illuminates and the indicator "ON / Status" lights to confirm the heater operation.
Switching off the heater
By pressing the main switch ON / OFF again the heater operation is stopped.
After switching off, the lighting of the main switch is also off.
The indicator "ON / Status" goes off after approx. 3 minutes (cooling down of the heater).
Mode selector knob
With the mode selector knob you can select the desired functions of your heater by placing the index on the desired symbol.
- “Eco” mode reduces the electrical power consumption by reducing the max. heating power. Useful when saving the battery is more important than quick heating up.
- In the “Normal” heating the heater behaves like a standard heater.
- “Plus” increases the max. heating power by ~10%. It provides extra
power for quicker heating up.
- In “Ventilation” mode the blower runs but the heater is off.
Temperature selector
You can adjust the desired interior temperature with the temperature selector. Preferably the temperature selector should be in the marked range of the scale (comfort range).
LED
The status LED lights green in normal heating mode. Blinking indicates failure code; see the following faults section.
Error code
Faultless operation:
The normal operation of the equipment is represented by the status indicator, illuminating green light. After switching off the heater (main switch) the status indicator shows the normal cooling down process of the heater. After the heater has cooled down normally, the status indicator shuts off.
Fault:
During an operational fault a flashing code is displayed by the status indicator. This function enables a professional workshop to solve the fault in a fast way. In this case please visit a Webasto service station!
Page 5
If an error occurs, first check the fuse and plug connections to ensure that they are in proper condition and connected correctly. If the actions described below do not rectify the error, have the heater checked by Webasto­trained personnel.
Cause Remedy
No combustion after start and repeat start
Switch heater unit off (for at least 2 seconds) and then on again
Flame extinguishes during operation
Switch heater unit off (for at least 2 seconds) and then on again
Heater unit overheats and indicator flashes
Make sure that hot air can flow freely, allow heater unit to cool down, Switch heater unit off (for at least 2 seconds) and then on again
Vehicle voltage too low Charge battery
Switch heater unit off (for at least 2 seconds) and then on again
Cause Remedy
Combustion air and/or exhaust system blocked
Check combustion air and exhaust system for blockage
Actions in event of faults
Heater unit cuts out automatically
Heater unit emits black smoke
Page 6
The error code is communicated by a series of flashes from the status LED in the bottm right corner of the bezel. After a sequence of 5 fast flashes the error code will be communicated by a series of long flashes; refer to the table below for code explanations.
Example:
F 03 =
If serious faults, such as overheating or no start, occur frequently, the heater will be set to permanent fault lock-out (F 12) and cannot be restarted until it has been repaired by Webasto-trained personnel.
Error code Meaning
F 00 Control unit error
F 01 No start (after 2 starting attempts)
F 02 Flame failure (at least > 3)
F 03 Undervoltage or overvoltage
F 04 Premature flame recognition
F 06 Temperature sensor interrupt or
temperature sensor short circuit
F 07 Metering pump interrupt or metering pump
short circuit
F 08 Fan motor interrupt or
fan motor short circuit or fan motor overload or blocked
F 09 Glow plug interrupt or
glow plug short circuit
F 10 Overheating
F 11 Overheating sensor interrupt or overheating
sensor short circuit
F 12 Heater unit lock-out
F 14 Overheating sensor installed incorrectly
F 15 Setpoint generator short circuit
Error code output on combination timer or control element
Pause
Pause
Page 7
Page 8
Webasto Product N.A., Inc.
15083 North Road Fenton, MI 48430
Technical Assistance Hotline USA: (800) 860-7866 Canada: (800) 667-8900
www.techwebasto.com www.webasto.us
Org. 4/2012 Rev. N/A P/N: 5010546A