Maintenance and Safety Information
Ventilation option
Maintenance and Safety Information
NOTE:
!
1. Caution: When heater is in use, the surface of the hot air outlet may become hot to the touch. Contact with skin may cause burns.
2. Heater must be switched "off" when refueling at filling stations and/or while loading or unloading flammable materials for transport, to prevent the risk of explosion. Please review owner's manual for safety and use instructions.
3. The installation of the heaters must be performed in accordance with the Installation Instructions. If available, the approval certification is to be kept in the vehicle.
4. The year of the initial operation must be durably marked on the type plate of the heater by removing the years that are not applicable.
5. The heaters are not approved for use in the cargo space of vehicles carrying hazardous materials.
6. Claims can only be asserted if the claimant can prove that the maintenance and safety notes were adhered to.
7. Due to the danger of explosion the heater must be switched off at filling stations and tank farms.
8. Due to the danger of poisoning or asphyxiation the heater must not be operated in enclosed spaces (e.g. garages) without adequate exhaust extraction. This should be considered when pre-setting heater operating times or using the Telestart remote control.
9. The heater must be inspected by a qualified expert annually, preferably prior to the heating season commencing.
10. In the case of severe smoke development, unusual combustion noises or fuel smell, the heater must be placed out of operation by removing the fuse and may only be restarted after it was inspected by Webasto-trained personnel.
11. At locations where combustible vapours or dust may accumulate (e.g. in the vicinity of fuel, coal, sawdust and grain depots or the like) the heater must be switched off due to the danger of explosion.
12. Whenever the heater is removed it is mandatory that the gasket located underneath be replaced.
13. The heat exchanger of the air heater is not to be used for longer than 10 years and must thereafter be replaced by the manufacturer or one of the authorised workshops with a genuine replacement part. If exhaust pipes lead through passenger areas, these pipes must also be replaced with genuine replacement parts after 10 years.
14. The fuel specified by the vehicle manufacturer is suitable as fuel for the heater. Both leaded and unleaded fuel may be used.
15. The heater should not be exposed to temperatures greater than 85°C (storage temperature). Exposure to such temperatures will cause permanent damage to the electronics.
Set the heater control to the desired temperature
A separately fitted switch provides you with the possibility to select between the "heating" and "ventilation" operating modes. The fan speed in the ventilation operating mode depends on the heater control position.
16. Webasto will not assume any liability if the installation instructions and the notes contained therein are not observed and performed by a Webasto trained installer/repair technician. The same applies to improperly performed repairs or those where others than genuine replacement parts have been used. In those cases, the heater’s General Design Certification and thus the General Operating Permit (homologation) will be invalidated as a consequence.
17. Heating air inlet and outlet openings must be kept clear of dirt and objects. Contaminated or obstructed heating air ducts can result in overheating and thus tripping of the temperature limiter.
18. To prevent mechanical parts from seizing, the heater should be operated every 4 weeks for approx. 20 minutes.
To prevent any obstruction or chafing of the heating and combustion air fans make sure that no objects are deposited on the heater nor rest against it, before putting the heater into operation.
Heater Control
Any changes in the settings adjusted at the heater control will take effect with some delay
!
Rotary dial for:
- turning on/off
- setting the desired room temperature
- deactivating any fault lock-out
Operation indicator/fault code display
Ident-Nr. 776 247
3/9708
Rev. 11/2015
Switching the heater on
Switching the heater off
Setting time/ day of the week
Viewing the time
Programming heater starting time
Recalling/ erasing preset times
Programming duration of operating time
Setting the remaining operating time
Setting the wakeup time
Recalling/ erasing the wakeup time
Remote control
Manually: by pressing the button (continuous heating mode) Automatically: by programming the heater starting time
Manually: by pressing the button Automatically: after the programmed operating time has elapsed With the heaterrunning: by programming the remaining operatingtime
Press the button for more than 2 seconds - time of the day is flashing - and set the clock using the and buttons. Day of the week is flashing - adjust the day of the week.
With the ignition switched off: press the button
Press the button - the memory location is flashing - using the and buttons set start of the heater operating time. Day of the week is flashing - set the day of the week. By repeatedly pressing the button, memory locations 2 and 3 can be programmed or the time display mode can be reached.
Repeatedly press the button until the desired memory location is displayed. To erase the preset time, press the button several times until the time of the day is displayed instead of the memory
The heater must be switched off. Press the button for 3 seconds ­operating time is flashing - and set the desired operating time (10 to 120 minutes) using the and buttons.
Set the desired remaining operating time (1 to 120 minutes) using the and buttons. The remaining operating time refers to the time the heater still continues to remain in operation. It can only be changed while the heater is in operation and the ignition switched off.
A wakeup time can only be programmed on the standard digital timer. The wakeup time is not bound to a specific day of the week. Repeatedly press the button until the bell symbol appears on the display. Set the desired wakeup time using the and buttons.The alarm clock turns off after 5 minutes or when one of the buttons is pressed.
Repeatedly press the button until the bell symbol appears on the display - read off wakeup time. To erase the wakeup time: press the button until the bell symbol is no longer visible on the display.
Possible by means of an optional external "instant heating" button