Important
Please read the entire manual before proceeding with the
installation and startup. Your failure to follow any attached
instructions or operating parameters may lead to the product’s
failure.
Save manual for future reference.
IOM-WQ-PWDWRVWG2
PWDWRVWG2
Table of Contents
System Specifications .................................2
Operation ..........................................3
Installation ..........................................3
Maintenance ........................................3
Replacement Parts List ................................3
Limited Warranty .....................................4
Note: Do not use with water that is microbiologically unsafe or
of unknown quality without adequate disinfection before or after
the system.
System Specifications
Maximum Pressure: 85psi (8.6 bar)
Maximum Temperature: 100°F (38°C)
Inlet/Outlet Connections: ½" (15mm) FNPT
Maximum Flow Rate: 2 GPM
Filter Cartridge Life Span
Cartridges should be changed at least every 6 months or sooner
depending on incoming water quality.
Replacement Filter Pack
MODEL FREQUENCY DESCRIPTION
PWFPKWGZW 6 Months
Note: Water conditions may require more frequent cartridge replacement
Notice to Installer
• Do not discard this manual after installation. This manual contains
important operation, maintenance and precautionary information.
Please present this manual to the user/owner/operator after installation.
• It is strongly suggested that you read this manual before installing
system to ensure the best possible installation.
• Installation must comply with all local and state plumbing codes
and regulations.
• Connect the system to cold water supply only. Water Temperature
cannot exceed 100°F (38°C).
• System must be installed in a vertical, upright and level position.
• Do not use with water that is microbiologically unsafe or of un-
known water quality.
• Notice to user/owner/operator: Please retain this manual for a
future reference for parts, maintenance, or troubleshooting.
• It is recommended that all personnel responsible for operation and
maintenance of this product read the precautions, maintenance,
and operations section of this manual.
includes sediment and
carbon filter
Installation Precautions
• Do not install system on line pressure above 85psi, if water pressure is over 85psi (8.6 bar). Watts recommends the installation of a
Watts Pressure Regulator.
• Do not install the system on a hot water line. Failure to limit the
water temperature to 100°F (38°C) can result in housing failure and
property damage.
• Do not connect the system backwards with the feed water line
connected to the outlet.
• Do not use liquid pipe thread compounds for threaded connections. Use Teflon
• Do not allow the system to freeze. Turn off water supply and drain
the system if temperature falls below 32°F (0°C).
• Do not install system in direct sunlight or where the system will be
exposed to harsh chemicals or may be subjected to being hit by
moving equipment, carts, mops, or any other item that may cause
damage.
• Allow 3" (76mm) minimum clearance under the housings for lter
replacement.
• If water hammer is evident, install water hammer arrestors before
the system.
• Do not over tighten tting connections.
• Always back up ttings with a wrench when installing ttings to
avoid over tightening or loosening existing fittings.
• Do not install the unit behind equipment where it may be difcult to
access the system for future filter replacements.
Position the system in a suitable location. The direction of flow
through the system is left to right. Keep this in mind when determining installation locations. Do not mount the system near any source
of heat. Also do not mount this system over anything that may be
adversely affected by water.
®