Watts PWDWHCUC1 Installation, Operation And Maintenance Manual

Page 1
Installation, Operation and Maintenance Manual
Under Counter Water Filtration System Model PWDWHCUC1
PURE WATER
!
WARNING
Please read carefully before proceeding with installation. Your failure to follow any attached instructions or operating parameters may lead to the product’s failure. Keep this Manual for future reference.
!
WARNING
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
IOM-WQ-PWDWHCUC1
The PWDWHCUC1 is certied to NSF/ANSI 42 for reduction of aesthetic chlorine, taste and odor, NSF/ANSI 53 for the reduction of cysts, and NSF/ ANSI 372 for lead free compliance.
PWDWHCUC1
Table of Contents
Operational Parameters...................................3
Contents of
Tools Recommended for Installation .........................3
How To Use Quick-Connect Fittings For Tubing Connections ......3
Blue Tube Connection - Angle Stop Valve .....................4
Blue Tube Connection - Faucet Hose ........................4
System Module Mounting .................................4
System Start up.........................................4
Annual Maintenance .....................................4
Parts List / Unit Drawing ..................................5
Performance Data Sheet .................................5
Limited Warranty ........................................6
Page 2
Introduction
Thank you for your purchase of a Watts water treatment system.
sediment, cyst and chlorine reducing filter block. The PWDWHCUC1 water filtration provides clean, clear, great tasting water with a higher flow and gal-lon rating than other similar systems.
Your new water treatment system contains a heavy duty
System Maintenance
Just because you cannot taste it, does not mean that it is not there. Many contaminants in the drinking water are undetectable to the taste. Additionally, over time if you do not replace the filter element, other bad tastes and odors will be apparent in your drinking water.
This is why it is important to change out your filter at the recom­mended intervals as indicated in this system manual. When replacing the filter element, pay special attention to any cleaning instructions. Should you have any further questions please refer to our website at www.watts.com/purewater or call our customer service department at 1-800-244-1299.
With proper installation and maintenance, this system will provide you with high quality water for years to come. If you have any ques­tions or concerns, please contact our Customer Service department at 1-800-244-1299 or refer to our on-line troubleshooting at www.watts.com/purewater.
Filter Replacement Date
Model Number:____________________Serial Number: __________________________ Date of Purchase:___________ Date of Install:______________
Installed by: ____________________________
IMPORTANT
If you are unsure about installing your Watts water filter, contact a Watts representative or consult a professional plumber.
!
CAUTION
Test the water periodically to verify that the system is performing satisfactorily. Discard small parts remaining after the installation.
NOTICE
Failure to install the system correctly voids the warranty. Handle all components of the system with care. Do not drop, drag or turn components upside down. Be sure the floor under the water filter system is clean, level and strong enough to support the unit.
2
Page 3
Operational Parameters
System is intended to be installed on the cold water line
ONLY. Do not use with hot water supply.
• Do not install if your water lines are susceptible to water
hammer.
• System to be used with municipal or well water sources
properly treated and tested on regular basis to insure
suitable and non-adverse water conditions, including
bacteriological safe quality.
Operating Temperatures Maximum 100°F (37.8°C) Minimum 40°F (4.4°C)
Operating Pressure
Maximum 125psi
(689 kpa) pH Parameters Maximum 10 Minimum 5 Flow Rate
1.6 GPM @ 60psi
Minimum 25psi
(172 kpa)
How to use the Quick-Connect fittings
To make a connection, the tube is simply pushed into the fitting. Place a piece of tape tube should be inserted. The unique patented Quick-Connect lock­ing system holds the tube firmly in place without deforming it or restricting flow
Cut the tube square. It is essential that the outside diameter be free of score marks and that burrs and sharp edges be removed before inserting into fitting.
1
2" from end of tube to indicate how far the
Contents of Under Counter System
1 Filtration System 1 Filter - Attached
1 Parts Bag (blue tubing, brass insert, brass nut, QC stem
adapter, QC union, delrin sleeve, mounting screws)
Check to confirm that you have all parts. Inspect all parts for
signs of damage, cracks, kinks, wear or breaks. DO NOT USE if
damages in any way. Contact If any of the items are missing
please contact Watts Customer Service for replacement parts.
Fitting grips before it seals. Ensure tube is pushed into the tube stop.
Push the tube into the fitting, to the tube stop. The collet (gripper) has stainless steel teeth which hold the tube firmly in position while the O-ring provides a perma­nent leak proof seal.
ull on the tube to check that it is secure. Always test the system for leaks
P
following installation and before use, and periodically during use.
Tools Recommended for Installation
√ Phillips bit for electric drill
√ Sharp Knife or Scisors
1/2" Adjustable
√ Electric Drill
Wrench
o disconnect, ensure the system is depressurized before removing the tube. Push
T in collet squarely against face of fitting. With the collet held in this position, the tube can be removed. Do not reconnect. Quick-Connect fitting can be reused only on
a new connection or after existing tube ends are recut free of score marks, burrs and damage.
3
Page 4
STEP 1
Blue Tube Connection- Angle Stop Valve
NOTICE
Do not use with hot water supply. Hot water will severely damage your system, will not filter properly, and can result in leaks and property damage. Water supply line to the system must be from the cold water supply only.
NOTICE
Step A - Turn off the cold water
Step B - Open cold water sink
Step C - Place a small container
Step D - Locate the blue 3/8” tube
Step E - Insert the assembled blue tube into the open fitting of the
supply to the faucet by turning the angle stop valve completely off.
faucet to relieve pressure.
under the cold water angle stop valve to catch any runoff water. Discon­nect the cold water faucet supply hose from the cold water angle stop valve.
in the parts bag. Remove a brass nut, plastic delrin sleeve and brass insert from the parts bag. To assemble, place the brass nut on the blue tube first (Open end out), then the sleeve and then push the brass insert all the way into the end of the tube. (See Picture).
cold water angle stop valve and simply tighten using an adjustable wrench. DO NOT OVER TIGHTEN.
STEP 2
Blue Tube Connection- Faucet Hose
Step A - Locate the threaded 3/8” male stem
adapter fitting in the parts bag. Thread the stem adapter on to the supply hose attached to the faucet and tighten with an adjust-able wrench.
Step B - Locate the 3/8”x3/8” Quick Connect union in the parts bag. Push the union on to the 3/8” stem adapter fitting attached to the faucet hose until fully seated.
Step C - Connect the open end of the 3/8” blue tube to the open end of the 3/8”x3/8” Quick con­nect union fitting by pushing the tube into the adapter until fully seated.
STEP 3
System Module Mounting
Step A – Determine best location for the filtration system to be mounted
and spliced into the 3/8” blue tubing. Using the mounting holes on the bracket, mark the location for the mounting screws on the cabinet wall under the sink (Make sure to leave enough room to remove the filter during
filter changes, approximately 2” below filter). In the parts bag, locate the two self tapping screws. Using an electric drill with a Phillips bit, screw them into the cabinet at the marked location. Hang the system on the screws using the mounting holes in the bracket
- Wood Surface
STEP 4
Blue Tube Connection - Filtration System
Step A - After mounting the system,
Step B - Connect the 3/8” blue tube
determine where and cut the 3/8” blue tubing into two parts in order to connect it to the filtration system.
coming from the angle stop valve into the left side of the filtration system (IN), by pushing the tubing firmly into the quick connect fitting. Connect the 3/8” blue tube coming from the faucet supply hose into the right side of the filtration system (OUT), by pushing the tubing firmly into the quick connect fitting.
System Start Up
Step A– Slowly turn on water. Check for signs of leaks or damage at all
locations including water supply connection, at cold water faucet hose connection, at quick connect fittings, at angle stop valve connection and at filter module and cartridges. Inspect connections, lines and filter module/ cartridges at least every six months thereafter for signs of leaks or damage. Turn water off immediately and replace if leaking, weeping, cracked, damaged or corroded.
Step B – Run 5 gallons of water through the unit in order to flush out the normal black carbon fines (it will “sputter” until the air is purged out) from the unit. Initially, the water may appear cloudy which is due to tiny air bubbles and it will clear up shortly. Close the faucet when finished.
NOTICE
Check frequently over the next 24 hours to ensure no leaks are present
Maintenance
Ordering Code: EDP# 7100643 Includes: (1) Carbon Block Cyst Filter Step A – Turn off incoming water supply to the filtration unit.
Step B – Open the cold water faucet handle to relieve the water pressure
Annual Filter Change Out
NOTICE
NOTICE At least every 12 months, you must change the filter with a
new Watts filter.
No one who has a compromised or weak immune system
!
WARNING
should change filters due to possible exposure to germs and bacteria. Always wear gloves and thoroughly wash hands immediately after changing filter.
Step C – Remove filter from lid by turning it to the left, then pull-
Step D – Remove plastic wrapping and cap from new filter. Step E – To install new filter cartridge, with the filter label facing
Step F – Follow System Start Up procedure.
Routine Maintenance
Step A - Regularly check for any leaks or damaged parts or connections. Step B times with nothing touching filter, tubes or connections. Step C - Regularly test water supply and output to confirm water condition and filter performance.
ing the filter down out of the lid. Properly dispose of old filter. Do not reuse. Cannot be recycled.
approximately 45 degrees to the left, push the filter into the lid and hand twist it to the right until the filter locks in and the label on filter is facing the front.
- Make sure system installation has adequate clearance at all
4
Page 5
Performance Data Sheet
WATTS 8716 W Ludlow Drive Suite #1
Peoria, AZ 85381
PWDWHCUC1
GENERAL USE CONDITIONS:
!
WARNING
1: System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. DO NOT use with water that is micro biologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. 2: Operating Temperature: Maximum 100 3: Operating Water Pressure: Minimum 25-psi (172kpa) 4: Maximum flow Rate: 5: Rated Capacity (Chlorine):
Maximum 125
1.6 gpm (6.06 lpm) 10000 Gallons (37,854 liters)
o
F (38o C) Minimum 40o F (4.4o C)
-psi (689kpa)
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVAL:
Depending on incoming feed water conditions replacement time frame may vary.
Description Part Number Change time Frame
PWCBHCUC1 7100643 10000 gallons of water
The PWDWHCUC1 system has been tested according to NSF/ANSI 42, 53, for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specied in NSF/ANSI 42.
While testing was performed under standard laboratory conditions, actual performance may vary.
Testing parameters: Flow rate 1.6 gpm pH 7.6 gpm Water pressure: 60 psi.
Cyst Reduction Flow Reduction Influent Effluent 1 Effluent 2
Influent Avg. 370000 count/L Eighth Cycle 130000 <25 <25 Effluent Avg. <25 count/L 25% 210000 <25 <25 Percent Reduction >99.98 % 50% 333000 <25 <25 Maximum Effluent <25 count/L 75% 810000 <25 <25
The PWDWHCUC1 is certied to NSF/ANSI 42 for reduction of aesthetic chlorine, taste and odor, NSF/ANSI 53 for the reduction of cysts, and NSF/ ANSI 372 for lead free compliance.
Under Counter System
6
Parts List
5
7
4
8
3 2 1
IteM # OrderIng cOde descrIPtIOn
1
2
3
4
5
6
7
8
7300767
7300768
7300769
7300067
7300770
7300771
7300766
7100643
3/8" Brass Insert (not shown) 3/8" Delrin Sleeve (not shown) 3/8" Brass Nut 3/8" Blue Tubing 3/8" QC Union 3/8" QC Stem Adapter System Head Assembly 15" HC Carbon Filter
To Loosen To Tighten
5
Page 6
WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
For more information: www.watts.com/prop65
LIMITED WARRANTY: Certain Watts Pure Water products come with a limited warranty from Watts Regulator Co. Other products may have no warranty or are covered by the original manufacturer’s
warranty only. For specic product warranty information, please visit www.watts.com or the published literature that comes with your product. Any remedies stated in such war­ranties are exclusive and are the only remedies for breach of warranty. EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY, IF ANY, WATTS MAKES NO OTHER WARRANTIES, EXPRESS OR
IMPLIED. TO THE FULLEST EXTENT PERMITTED BY APPLICABLE LAW, WATTS HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND IN NO EVENT SHALL WATTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR PROPERTY DAMAGE, REGARDLESS OF WHETHER IT WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES.
A Watts Water Technologies Company
IOM-WQ-
PWDWHCUC1 1551 299803 © 2015 Watts
USA: Tel. (800) 224-1299 • www.Watts.com/PureWater
Canada: Tel. (888) 208-8927 • www.Watts.ca/PureWater
Loading...