Watts PWBOOST05KT User Manual

Instructions for Installing Model PWBOOST05KT Low Flow Booster Pump Kit
Package Contents: 1 Booster Pump 1 Transformer
Installation
2. Cut the ¼" green line going from your tap connection to your Reverse Osmosis unit allowing for placement of pump. Attach the line from the cold water angle stop valve side of the green tubing to the inlet side of the booster pump (2 pieces of additional green tubing are provided if needed).
3. Mount the pump to a convenient location near the reverse osmosis unit (mounting pump is not necessary but will reduce vibration & noise).
4. Connect the ¼" green line from the RO unit to the outlet side of the booster pump.
5. Cut the blue line (¼" for standard units or verse osmosis unit to the storage tank. Insert the TSO (Tank Shutoff Switch provided) at this location (you will need to use the ing or a “Standard” style unit). This shutoff switch does not have a directional flow and can be installed either direction on the blue line.
6. Turn on incoming water to reverse osmosis system and check for leaks. Plug trans­former into electrical outlet and make sure all electrical connections are made. Open tank ball valve if so equipped.
7. Check for leaks periodically as the system fills and again after it shuts off (tank full and approximately 24 hours after installation).
1 TSO (Tank Shutoff) Switch
3
8" to 1⁄4" Reducer Fittings
2
1
4" Green Tubing
2
3
8" for manifold units) leading from the re-
3
8" to ¼" reducer fittings if you have ¼" tub-
IS-WQ-PWBOOST05KT
Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with­out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
Manifold Style Unit
Standard Style Unit
Reverse Osmosis
Water Faucet
Standard Sink
Water Faucet
Standard
Sink
Drain
Reverse Osmosis
Storage Tank
Hot Water
Angle Stop
Valve
Cold Water Angle Stop
Valve
(Blown-Up View of the End of the Unit)
TAP
FAUCET
Pump Flow
Direction
Electric
Pump
TANK
Pressure
Switch
DRAIN
Transformer
110VAC to 24VAC
Wire Harness
for pressure
switch
Reverse Osmosis
Water Faucet
<-- Flow--
Standard Sink
Water Faucet
Standard
Sink
Drain
Reverse Osmosis
Storage Tank
Hot Water
Angle Stop
Valve
3/8" to 1/4"
Reducer
Fittings
Pressure
Switch
Cold Water Angle Stop
Valve
Membran e
Flow Restrictor
Pump Flow
Direction
Electric
Pump
Transform er
110VAC to 24VAC
Wire Harness
for pressure
switch
LIMITED WARRANTY: Certain Watts Pure Water products come with a limited warranty from Watts Regulator Co. Other products may have no warranty or are covered by the original manufacturer’s warranty only. For specic product warranty information, please visit www.watts.com or the published literature that comes with your product. Any remedies stated in such warranties are exclusive and are the only remedies for breach of warranty. EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY, IF ANY, WATTS MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. TO THE FULLEST EXTENT
PERMITTED BY APPLICABLE LAW, WATTS HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND IN NO EVENT SHALL WATTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR PROPERTY DAMAGE, REGARDLESS OF WHETHER IT WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES.
A Watts Water Technologies Company
USA: Tel. (800) 224-1299 • www.watts.com
Canada: Tel. (888) 208-8927 • www.watts.ca
IS-WQ-PWBOOST05KT 1225 EDP# 2915881 © 2012 Watts