OneFlow® Anti-Scale System
Chemical-Free, Salt-Free Scale Prevention
Model OF744-10
Model OF844-12
IOM-OF744/844/948/1054/1252
Model OF948-16
Model OF1054-20
Model OF1252-30
Introduction
The Watts OneFlow® system provides protection from scale
formation throughout the plumbing system. The OneFlow
system can be installed at the point of entry to treat your
entire system, both hot and cold water, or it can be located
directly before a water heater or other device (e.g. steamer,
etc) that requires protection from hard water.
OneFlow
and external plumbing surfaces as well as reducing spotting
and streaking normally associated with hard water.
OneFlow
solved hardness minerals into undissolved crystal micro-particles. These crystals stay suspended in the water and have
a greatly reduced ability to react and attach to surfaces like
dissolved hardness does. Therefore, the problem of internal
buildup of scale in pipes, water heaters and on fixtures and
glass is greatly reduced.
®
reduces or eliminates scale formation on internal
®
prevents scale by transforming the normal dis-
®
OneFlow
cleaning products are recommended to achieve optimum
results. Modern surfactant or detergent based, liquid soaps
are preferred over old-fashioned caustic solid soaps.
Unlike softened water, OneFlow
the beneficial essential mineral content of your water and is
safe to drink.
®
is not a water softener – Low or phosphate-free
®
treated water maintains
OneFlow® Benefits
• Chemical free scale prevention. Provides cost savings and
environmental benefits
• Virtually maintenance free. No salt bags or other chemicals
to buy, transport and store
• No electricity, no wastewater, completely self-contained
• Beneficial minerals retained for more healthful drinking
water
• Improves the efficiency of water-using appliances.
• Simple installation – no electrical and drain hookup
• Safe for landscaping and lawn watering. No need for costly
bypass plumbing
• Compatible with all on-site and community wastewater
treatment systems
• Not subject to water softener restrictions and “bans”
System Overview
Tank Head
Media Tank
Typical Connection Fittings
CK-V3007-02
1" Brass Sweat
Fitting
(EDP#0027170)
CK-V3007
1" PVC Male NPT Elbow
Assy.
(EDP#0002169)
Optional Connection Fittings
CK-V3006
Bypass Assy.
(EDP#0002167)
CK-V3191-01
Bypass Elbow
Assy.
(EDP#002168)
2
Equipment Specifications
Watts OneFlow® systems are complete, self-contained, loaded
with media and ready to use. A simple inlet and outlet connection is all that is required for installation. Please review operating pressures, temperatures and water chemistry limitations to
ensure compatibility.
* See note about iron, manganese and copper on the next page.
Mechanical Specifications
Model74484494810541252
Max Service Flow
(gpm)
Dry Weight (lbs)2225293543
Service Weight (lbs)8097129168235
1012162030
ab
c
e
Dimensions (nominal - inches)
a4747495855
b4646485754
c7891012
d1.01.01.01.01.0
e3.03.03.03.03.0
Using OneFlow® with other water treatment
equipment.
Due to the unique properties of OneFlow®, there are some
unique requirements for using OneFlow
tion or other forms of water treatment.
1. OneFlow
not install any filters after OneFlow
which scale prevention is required. POU drinking water filters,
e.g. carbon or RO are exempt from this requirement.
2. Do not apply phosphate or any other antiscalant either before
or after OneFlow
®
must be the last stage in the treatment chain. Do
®
.
®
in conjunction with filtra-
®
or before any devices for
3
Important note about iron, manganese and copper
!
in the water supply
Iron and Manganese
Just as with conventional water softening media, OneFlow® needs
to be protected from excess levels of certain metals that can
easily coat the active surface, reducing its effectiveness over time.
Public water supplies rarely, if ever, present a problem. However,
if the water supply is from a private well, confirm that the levels
of iron (Fe) and manganese (Mn) are less than 0.3 mg/L and 0.05
mg/L respectively. Copper should be less than 1.3 mg/L.
!
Cautions!
• Do not let the system freeze. Damage to the tank may result.
• System must be operated in a vertical position. Do not lay
it down during operation. The system may be placed in any
position for shipping and installation but must be operated in
the vertical position.
• Place the system on a smooth, level surface. Because the
system operates in an UP-Flow, fluidized bed mode, having a
level surface is more important than with a softener or media
filter.
• A bypass valve should be installed on every system to facilitate
installation and service.
• Observe all local plumbing and building codes when installing
the system.
Copper
Copper usually originates from new copper plumbing upstream
of the OneFlow
waiting 3-4 weeks before placing the system in operation. This
will allow the copper surfaces to be fully flushed and develop a
natural protective surface. To further minimize any problem with
excess copper, avoid applying excess flux on the inner surfaces
of the pipe and use a low-corrosivity water soluble flux listed
under the ASTM B813 standard. Once the plumbing connections
are complete, place the OneFlow
lowing the startup procedure and flush the plumbing for at least
10 minutes.
Notes to the Installer
i
The OneFlow® system differs from a conventional softener or
media filter in a number of key respects.
• The system is light and only partially filled with media. This is
normal. The UP-flow operation of the system requires a lot of
freeboard to allow the bed to fully fluidize.
• The system has no underbed so you can tip the system over
without any fear of upsetting the media. This makes transportation and installation much easier than conventional systems.
• Because the OneFlow
the tank connections are opposite of traditional installations.
• Please see the “Important note about iron, manganese and
copper in the water supply” above.
• Please see the note about “Using OneFlow
treatment equipment” on the previous page.
®
system. If this condition exists, we recommend
®
system in bypass prior to fol-
®
system operates in the UP-flow mode,
®
with other water
4
Installation and Start-up
IN
Cold Water
OneFlow
OUT
®
Treated Water
1. Place the system in the desired location.
2. Connect the cold water supply to the inlet of the OneFlow
system.
NOTE: The OneFlow
which is opposite of a conventional softener.
3. Place a bucket under the outlet port or run a line from the
outlet port to a drain.
5. Slowly open the supply valve (user supplied) to the
OneFlow
supply valve when a steady stream of water comes out of
the outlet port.
6. Connect the outlet of the OneFlow
water supply of the building.
7. Open the supply valve to the OneFlow
8. Open faucets downstream from the OneFlow
relieve any air.
9. Check for leaks. Repair as needed.
10. The system is now ready for service.
®
system. Allow the tank to fill with water. Close the
®
system operates in the UP-flow mode
®
system to the cold
®
system.
®
system to
®
Figure 1.
Model OF844-12 shown with
optional bypass assemby.
Bypass Valve Modification
Service Position
down-flow tank.
Service Position
UP-flow tank.
5
As shipped, the bypass is set-up for downflow use. The arrow shape of the handles
points in the wrong direction for UP-flow
use. To convert it to UP-flow use, pull up on
the red handles until they come off. Rotate
the handle 180° and put it back on the valve
stem.
Bypass Position
UP-flow tank.
Note to the building owner
Your OneFlow® system will improve the properties of water
throughout your building. Here are some things to expect and
some recommendations for maximizing the benefits and your
enjoyment of OneFlow
Dishwasher-Spotting on dishes and on the surface of the
dishwasher should be greatly reduced or eliminated. We
recommend that you immediately reduce the amount of dishwashing detergent by approximately 50% as compared to
hard water use. Dishwashing
detergents low in phosphates
are highly recommended as
they are better for the environment and phosphates can
cause spotting. In very hard
water areas, the use of a rinse
aid may be advised.
Shower doors and tiles- should
have little or no spotting. When
water evaporates off a surface, small
spots may be left behind. These
spots should be easy to remove with
a damp cloth or sponge.
In the bath you should notice that
soaps and shampoos lather
more than with un-treated water. Soaps and shampoos will
also rinse off much easier and
faster than they would with
traditional soft water. We recommend the use of modern
soaps for the best results.
®
Sinks and fixtures - should
have little or no spotting. If water
is allowed to evaporate off a
surface, small spots may be left
behind. This spotting should not
require any more than a wet cloth
or sponge to remove. No harsh
chemical should be required as
with typical hard water spotting.
Things to watch for:
During the first 30-90 days:
• Faucet aerators and drains may plug occasionally as old scale is
removed from your plumbing system and water heater.
• You may also see milky water while the descaling is taking
place. This is simply an increase in the calcium in the water because OneFlow
®
is removing old scale deposits from your pipes.
Good practices:
If your dishwasher is severely coated with scale at the time of
installation, we recommend that you purchase a product like
®
Jet-Dry
initial cleaning OneFlow
We also recommend that you drain your water heater tank. This
should be done 30 to 60 days after OneFlow
again in one year. This is a good practice that can dramatically increase the life of your water heating appliance. The OneFlow
help keep the tank and heating elements free of scale and operating at peak efficiency. Please follow the manufacturers instructions
when draining the tank!
Dishwasher cleaner to accelerate the cleaning. After this
®
should keep it clean.
®
is installed, and
®
will
Jet-Dry
®
is a registered trademark of Ecolab, Inc.
6
Limited Warranty
• The OneFlow® tank system is warranted to be free of defects in materials and workmanship for 5 years from the date of original shipment.
• The OneFlow
ated in accordance with the instructions in the corresponding Installation and Operation Manual.
Watts Regulator Company warrants its OneFlow
• The OneFlow
shipment.
• OneFlow
operated in accordance with the instructions in the corresponding Installation and Operation Manual.
• Carbon replacement filter cartridges are not warranted to perform for any period of time because the service life of replacement carbon
filter cartridges varies significantly with local water conditions and volume.
Conditions
1. The OneFlow® system must be installed in applications with municipally supplied water adhering to EPA guidelines.
2. Any component failure must not result from abuse, fire, freezing or other acts of nature, violence, or improper installation.
3. Equipment must be installed and operated in compliance with the local plumbing codes and on an approved water supply.
4. Equipment is limited to use at water pressures and temperatures that do not exceed our published specifications.
5. Water supply must not exceed 2.0 PPM chlorine. For water supply exceeding 2.0 PPM chlorine, pretreatment is required.
(Please contact your water treatment specialist.)
6. Information, including model number, serial number, and date of installation, must be provided for any claims pertaining to equipment in
warranty.
7. Defective parts are subject to inspection by either Watts Regulator Company or any authorized representative before final commitment of
warranty adjustment is made.
8. Watts Regulator Company reserves the right to make changes or substitutions in parts or equipment with material of equal quality or value
and of then current production.
®
media is warranted for performance for a period of 2 years from the date of the original installation when installed and oper-
®
cartridge systems as follows:
®
cartridge system is warranted to be free of defects in materials and workmanship for 1 year from the date of original
®
cartridges are warranted for performance for a period of one year from the date of original installation when installed and
Limitations
Our obligation under this warranty with respect to the tank or valve is limited to furnishing a replacement for, or at our option, repairing any
part or parts to our satisfaction that prove defective within the warranty period stated above. Such replacement parts will be delivered to the
owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any.
Our obligation under this warranty with respect to the OneFlow
years from date of original installation. Such replacement media will be delivered to the owner F.O.B. nearest factory, at no cost, excluding
freight and local labor charges, if any. Damage to the media due to chlorine, other oxidizers or fouling caused by local water conditions or
any other operation outside of the limits shown under Specifications, is not covered by this warranty.
THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY WATTS REGULATOR COMPANY
WITH RESPECT TO THE PRODUCT. WATTS REGULATOR COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. WATTS
REGULATOR COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
The remedy described under this warranty shall constitute the sole and exclusive remedy for breach of warranty, and Watts Regulator
Company shall not be responsible for any incidental, special or consequential damages, including without limitation, freight, handling, lost
profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from
labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any
other circumstances over which Watts Regulator Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication or improper installation of the product.
Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This warranty gives you specific legal rights, and
you may have other rights that vary from state to state. You should consult applicable state laws to determine your rights. SO FAR AS IS
CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE APPLICABLE
WARRANTY PERIODS STATED ABOVE.
®
media will be limited to furnishing a replacement for the media within two
7
A Watt s Water Technologies Company
Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca
USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com