Watts OF240-4 User Manual

For Commercial and Food Service Applications
ES-OF210_220_240
Job Name
Job Location
Engineer
Approval
–––––––––––––––––––––––––––––––––––––––––––
–––––––––––––––––––––––––––––––––––––––––
–––––––––––––––––––––––––––––––––––––––––––––
–––––––––––––––––––––––––––––––––––––––––––––
LEAD FREE
*
Contractor
Contractor’s P.O. No.
Representative
––––––––––––––––––––––––––––––––––––––––––––
––––––––––––––––––––––––––––––––––––––––––––––
––––––––––––––––––––––––––––––––––––––––
––––––––––––––––––––––––––––––––––
Models OF210-1, OF220-2 and OF240-4
OneFlow® Anti-Scale System
Connection Sizes: 1⁄2" and 3⁄4" (15 and 20mm)
Flow Rates: From 0.5 gpm to 4 gpm (1.9 lpm to 15.2 lpm)
The OneFlow vides protection from scale formation and reduces chlorine and other off tastes to improve overall water quality in Food Service applications. The OneFlow system that may be installed on a cold water line prior to a water-using device (coffee maker, espresso machine, post-mix system or other appliance) that requires protection from the ill effects of hard water. OneFlow the water is being heated or brought to steam.
OneFlow minerals into harmless, inactive microscopic crystal particles. These crystals stay suspended in the water and are passed to drain, thereby having a greatly reduced ability to react nega­tively like dissolved hardness does. The system requires very little maintenance, no backwashing, no salt, and no electricity. Typical hardness problems, especially build-up of scale in heat­ing elements, boilers, and steamers, are no longer a concern.
OneFlow or remove any minerals. It is a scale prevention device with proven third party laboratory test data and years of successful Food Service and Commercial applications. OneFlow intelligent scale solution with chlorine reduction as a great alter­native to water softening (ion exchange) or scale sequestering devices.
®
Anti-Scale System with two filter housings pro-
®
system is a dual cartridge-based
®
works exceptionally well where
®
prevents scale by transforming dissolved hardness
®
is not a water softener. It does not add chemicals
®
is the
OF210-1
OF220-2
Features
• Chemical free scale prevention and protection - converts
hardness minerals to harmless, inactive microscopic crystals making OneFlow softener for the prevention of scale due to water hardness and for the reduction of chlorine for better taste and odor
• Virtually maintenance free - No salt bags or other chemicals to
constantly add or maintain
• No control valve, no electricity and no wastewater
• Uses environmentally friendly “green” technology
• Improves efficiency of all water appliances whether heating the
water or not
• Simple sizing & installation – all you need to know is pipe size
and flow rate
Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with­out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
®
effective alternative technology to a water
• Perfect system for restaurants, cafeterias and coffee shops
where multiple or single equipment protection is desired for longer equipment life and reduced energy consumption
• Inlet ball valve for easy isolation shutoff and filter changes
• OneFlow
are linked to good health
• OneFlow
change the carbon cartridge every 6 months and the OneFlow
* The wetted surface of this product contacted by consumable
water contains less than one quarter of one percent (0.25%) of lead by weight.
For hot water applications where water temperature is 110°F - 150°F (43°C - 66°C), please consult ES-OneFlow-Hot Water.
®
does not remove the essential minerals in water that
®
cartridge-based systems are easily maintained;
®
media cartridge once per year.
OF240-4
Models
Model Maximum Flow Rate Connection Sizes
OF210 – 1 1 gpm (4 lpm)
OF220 – 2 2 gpm (8 lpm)
OF240 – 4 4 gpm (15 lpm)
1
2” (15mm) FNPT
1
2” (15mm) FNPT
3
4” (20mm) FNPT
Replacement Cartridge
OF110RM Cartridge should be replaced every 12 months
OF120RM Cartridge should be replaced every 12 months
OF140RM Cartridge should be replaced every 12 months
OF110RC Cartridge should be replaced every 6 months
OF120RC Cartridge should be replaced every 6 months
OF140RC Cartridge should be replaced every 6 months
Specifications
A OneFlow® scale prevention system with added carbon filtra­tion shall be installed on the cold water service line to condition and filter the tap water just prior to the service line feeding the
equipment it is designed to protect. The system will be sized
for maximum or peak flow rate based on the specification of said equipment. A OneFlow tion may also be installed to protect multiple pieces of equip­ment from the ill-effects of hard water scale and taste/odor concerns provided the aggregate peak flow rate for each piece of equipment it is protecting has been considered. The system shall be plumbed with a bypass valve to allow isolation of filter housings to allow the bypass of untreated water in the event that service or cartridge replacement is necessary. The instal­lation area should be suitable in size for the housing to be ser­viced without encumbrance and the system should be installed per the Installation, Operation & Maintenance manual as pro­vided with each system.
The OneFlow
®
system must not require additional waste water to backwash, flush, or regenerate once put into service. The system shall not require any chemical additives and shall not require electricity for operation.
®
system with added carbon filtra-
Water Chemistry & Limitations
pH 6.5 to 8.5 Hardness (maximum) 75 grains (1300 ppm CaCO3) Temperature 41°F to 100°F (5° to 38°C)
Chlorine < 3ppm Iron (maximum) 0.3 mg/l
Manganese (maximum) 0.05 mg/l
Copper none allowed
Oil & H2S none allowed
Polyphosphate none allowed Silica (maximum) 10 ppm
Standards
Independent scientific testing has confirmed Template Assisted
Crystallization (TAC) technology provides scale reduction of over 95+%. Testing was conducted under protocol based on DVGW W512 test to access control of scale formation.
C
A
D
B
E
A
Note: Copper lines need to be passivized for a minimum of 4 weeks before placing unit into service. Not for use on closed loop systems.
Dimensions — Weights
Clearance
Model Dimensions Weight
A B C* D E*
in. mm in. mm in. mm in. mm in. mm lbs. kgs.
1
OF210-1 14 OF220-2 24 OF240-4 26 66 15
2 37 91⁄4 24 51⁄8 13 111⁄4 29 53⁄4 15 9 4.1
1
2 62 91⁄4 24 51⁄8 13 111⁄4 29 53⁄4 15 14 6.4
1
4 39 85⁄8 22 175⁄16 44 121⁄4 31 31 14.1
The overall height and the height of the fitting varies due to material variations and assembly tolerances. Please allow additional clearances above the tank for making connections.
A Watts Water Technologies Company
ES-OF210_220_240 1140 © 2011 Watts
USA: No. Andover, MA • Tel: (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com
Canada: Burlington, ON • Tel: (905) 332-4090 • Fax: (905) 332-7068 • www.wattscanada.ca