Optional IP Module Kit .............................................................................................................................................3
Installing CommLink 5 ONLY ...................................................................................................................................3
System Requirements ..............................................................................................................................................3
CommLink 5 LED Descriptions ..................................................................................................... 12
Connecting the Network .............................................................................................................. 13
Proxy and Firewall Compatibility ............................................................................................................................13
Troubleshooting T ips ..............................................................................................................................................14
Changing the USB Serial COM Port Number ........................................................................................................15
The OE361-13 CommLink 5 is used to transfer communications
between controllers or local loops on your control system. It can also
be used as an interface for connection of a computer to your system.
The CommLink 5 provides communication with the control system
through any computer that is running Prism 2 software. For remote
communications, an IP Module Kit can be installed for LAN and
Internet connections.
Optional IP Module Kit
The OE415-02 IP Module Kit, when installed and confi gured in
the CommLink 5 communication interface, provides TCP IP Internet and/or intranet connection for Ethernet networked computer
systems, allowing them to communicate with your control system.
The OE415-02 IP Module Kit consists of the IP Module and a 10
ft. long CAT5 Ethernet crossover cable.
Using standard TCP/IP Protocol, with WattMaster’s Prism 2 software, you are able to monitor and confi gure your controllers without
a modem or a direct connection from a PC. Utilizing existing routers, proxies, or fi rewalls allows a PC running Prism 2 to connect to
a controller in a remote accessible location or building. Several IP
connection profi les can be created to facilitate monitoring several
CommLink 5’s with IP Module Kits installed on individual sites.
Installing CommLink 5 ONLY
When you are using the CommLink 5 in an application without a
computer or IP Module, follow Steps 1 & 2 in the Quick Guide on
page 4.
WARNING: If you are replacing an earlier version of the
CommLink with a CommLink 5, be aware that the polarity
of the terminal block is reversed on the CommLink 5 from all
previous models. You must always confi rm that the polarity is
correct when wiring 24 VAC power to the CommLink power
terminal block or serious damage to the product will result.
NOTE: Please note, the R(+) and T(-) terminals on the
communications terminal block are reversed from all previous
versions of the CommLink.
System Requirements
To program the CommLink 5 to work with Prism 2, you will need:
Standard Items (Required)
• CommLink 5 with USB cable and power adapter
• A PC with an Ethernet communications port or USB
port (supplied by others)
• USB drivers on CD-ROM (supplied and also
downloadable from any of our websites)
®
• Microsoft Windows
on the PC you are going to use)
• Prism 2 software, version 4.0.3 or later (can be
downloaded from any of our websites)
Optional Items
IP Module Kit that comes with Ethernet RJ-45
•
Crossover CAT 5, 10 ft. long cable for LAN, and Internet
remote communications
• MiniLink, MiniLink PD, or MinkLink PD 5
XP, Vista, 7, or 8 (must be installed
Operator Interface
Revised: 11/6/12
3
CommLink 5 Technical Guide
Quick Guide
Quick Guide
Follow the fi ve steps below to get your CommLink up and running in
no time.
NOTE: If you are using the CommLink 5 without utilizing
Prism 2, you need only perform Steps 1 through 3.
Step 1: Set your CommLink’s Loop switch to Multiple or Single.
See Figure 2 on page 6.
Step 2: Set your CommLink’s Baud rate switch to High or Low.
See Figure 3 on page 7.
Step 3: Wire your CommLink to the appropriate controller on your
system, and plug the CommLink into a power supply. See
Figure 1 on page 5.
NOTE: Please note, the R(+) and T(-) terminals on the
communications terminal block are reversed from all previous
versions of the CommLink.
WARNING: If you are replacing an earlier version of the
CommLink with a CommLink 5, be aware that the polarity
of the terminal block is reversed on the CommLink 5 from all
previous models. You must always confi rm that the polarity is
correct when wiring 24 VAC power to the CommLink power
terminal block or serious damage to the product will result.
IMPORTANT NOTES:
First install the USB drivers, then follow the included
CommLink 5 connection and wiring instructions sheet
(Figure 1 on page 5) to connect and confi gure the
CommLink 5.
Familiarize yourself with all system components and
review all documentation. Pay special attention to
“Cautions,” “Notes,” and “Warnings” since these may
keep you from experiencing unnecessary problems.
If you encounter any problems, please refer to the
Troubleshooting section of this guide fi rst. If you
can’t resolve the problem, please call WattMaster
Technical Support at our toll free number—
1-866-918-1100.
Step 4: Install the USB drivers located on the included CD-ROM.
See instructions on page 8. Then attach one end of the USB
cable to the back of your CommLink and the other end into
your computer’s USB port.
Step 5: Install Prism 2 software on your computer. See instructions
on pages 10 & 11.
NOTE: For remote communication, follow the instructions
included in your IP Module Technical Guide.
4
Revised: 11/06/12
Operator Interface
CommLink 5 Technical Guide
CommLink 5 Connections & Wiring
Connections and Wiring
WARNING! If You Are Using The IP
Module With Your CommLink, Do Not
Have Your Ethernet Connection And
USB Connection Connected At The
Same Time. This Could Cause
Unreliable Communications.
10/100
ETHERNET
DIAG
ACT LNK
Optional Items
Not Required
For CommLink-Only
Installations.
USB Cable (Included).
Connect This Cable To
Your Computer USB Port
For Direct Connection To
The CommLink 5. Also
Used For Advanced
Configuration of The
CommLink 5.
Optional - PrefabricatedFt. Long CAT5
Ethernet Cable (Included With Optional OE41502 IP Module Kit).
Ethernet Router On Your LAN.
Ethernet Cable Is Required, You Will Need To
Obtain (From Others) And Install An Ethernet
Cable Of The Required Length For Your
Installation.
10
Connect To A 10/100 Base-T
If A Longer
When Using
A MiniLink,
Switch Should
Be Set To
Multiple.
COMPUTER
USB
MULTIPLE
SINGLE
LOOP
BAUD
HIGH
Communications
LOW
CommLink 5
Interface
GND
SHLD
T(-)
R(+)
485 LOOP
POWER
If Desired A 24 VAC Transformer
Included)
Used Instead Of The Supplied Power Pack.
Use 18 Gauge Minimum 2 Conductor Wire
Between The Transformer & CommLink 5
Terminals
NOTE: Please Note, The R(+) And T(-) Terminals
On The Communications Terminal Block Are
Reversed From All Previous Versions Of The
CommLink.
WARNING! If You Are Replacing An Earlier
Version Of The CommLink With A CommLink 5,
Be Aware That The Polarity Of The Terminal
Serial #
24V
Block Is Reversed On The CommLink 5 From
All Previous Models. You Must Always Confirm
That The Polarity Is Correct When Wiring 24 VAC
Power To The CommLink Power Terminal Block
Or Serious Damage To The Product Will Result.
24 VAC Power
18 Gauge 2 Conductor
With Shield (Not Included)
See Note 1
Connect To A
MiniLink PD, MiniLink
Or Other Controller As
Required By Your
Specific System
Wiring Instructions.
See Note 1
120 to 24 VAC Power Pack
(Included) Connect To 120/1/60
Duplex Receptacle (By Others)
Rated At 12 VA Minimum May Be
(Not
NOTES:
1) Use 18 Gauge Minimum 2 Conductor Twisted Pair With Shield Cable Belden #82760 Or Equivalent (Not Included) To Connect
The CommLink 5 To A MiniLink or MiniLink PD.
2) For Direct Connection Via USB, Your Computer Must Have An Unused USB Port Available. Drivers For Your USB Port Are
Provided On A CD Supplied With The CommLink 5. Please Follow The Directions In The CommLink 5 USB Driver Installation
Section (Included) To Install And Configure The USB Drivers.
3) The CommLink 5 Cannot Communicate With The Control System Through Its Ethernet Port And USB Port At The Same Time.
4) All Wiring Must Conform To Applicable Federal, State & Local Electrical Wiring Codes.
Figure 1: CommLink 5 Connection & Wiring
Operator Interface
Revised: 11/06/12
5