The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless author ized previously in
writing by the manufacturer.
In line with policy to continually develop and improve its p roducts, Moffat Ltd. reserves the right to change the specifications and
design without prior notice.
FN(L)(B)8120GE ‘FAST FRI’ GAS FRYER (Single Tank - 20Ltr).
FN(L)(B)8226GE ‘FAST FRI’ GAS FRYER (Twin Tank - 26Ltr).
FN(L)(B)8130GE ‘FAST FRI’ GAS FRYER (Single Tank - 31Ltr).
Controller Advanced Programmin g Mode .............................................. 28
Timing Mode.
Temperature Offset.
Temperature Display Mode.
Programming the Melt Cycle.
Setting the Temperature Units.
System Programmable Default Settings.
Gas Conversion and Specifications ........................................................ 31
Conversion Procedure.
Gas Specifications.
Replacement Parts List .......................................................................... 35
Introduction
We are confident that you will be delighted with your Waldorf ‘Fast-Fri’ Gas Fryer and it will become a most
valued appliance in your commercial kitchen.
To ensure you receive the utmost benefit from your new Waldorf ‘Fast-Fri’ Gas Fryer, there are two
important things you can do.
Firstly
Please read the instruction book carefully and follow the directions given. The time taken will be well
spent.
Secondly
If you are unsure of any aspect of the installation, instructions or performance of your Fryer, contact
your WALDORF dealer promptly. In many cases a phone call could answer your question.
CE Only
These instructions are only valid if the country code appears on the appliance. If the code does not
appear on the appliance, refer to the supplier of this appliance to obtain the technical instructions for
adapting the appliance to the conditions for use in that country.
It is recommended that a regular inspection is made by a competent service person to ensure
correct and safe operation of your appliance is maintained.
DO NOT store or use gasoline or other flammable vapours or liquids in the vicinity of this or any
other appliance.
do not spray aerosols in the vicinity of this appliance while it is in operation.
This appliance is for professional use and is only to be used by qualified
persons.
Only authorised service persons are to carry out installation, servicing or gas
conversion operations.
Components having adjustments protected (e.g. paint sealed) by the
manufacturer should not be adjusted by the user / operator.
DO NOT operate the appliance without the legs supplied fitted.
Caution
3
Specifications
Model Numbers Covered in this Specification
FN[1]8120GE ‘FAST FRI’ GAS FRYER (Single Tank - 20Ltr).
FN[1]8226GE ‘FAST FRI’ GAS FRYER (Twin Tank - 26Ltr per Tank).
FN[1]8130GE ‘FAST FRI’ GAS FRYER (Single Tank - 31Ltr).
NOTE:
[1]: - Model Options;
- - Standard.
L - Low Back.
B - Bold Front.
LB - Low Back and Bold Front.
Australia / NZ models - 10A 3-pin plug.
United Kingdom models - 13A 3-pin fused plug.
5
Dimensions
FN
(L)(B)
8120GE
2
1
3
FN
3
(L)(B)
3
2
1
8226GE
2
1
2
3
1
2
3
1
2
3
1
FN
(L)(B)
3
8130GE
2
1
3
2
3
1
1. Primary Gas Entry Point.
2. Optional Gas Entry Point.
3. Electrical Entry Point.
2
1
6
Installation
Installation Requirements
NOTE:
It is most important that this Fryer is installed correctly and that the operation is
correct before use. Installation shall comply with local electrical, gas and health and
safety requirements.
This appliance shall be installed with sufficient ventilation to prevent occurrence of
unacceptable concentrations of health harmful substances in the room, appliance is
installed in.
Waldorf ‘FAST FRI’ gas fryers are designed to provide years of satisfactory service, and correct installation
is essential to achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in
accordance with relevant National / Local codes covering gas and fire safety.
Australia / New Zealand AS 5601.1 - Gas Installations.
Australia / New Zealand: AS / NZS 3000 - Wiring Rules.
United Kingdom: Gas Safety (Installation and Use) Regulations 1998.
United Kingdom: BS 7671 - Requirements for Electrical Installations.
Ireland: IS 820 - Non Domestic Gas Installations.
Installations must be carried out by qualified service persons only. Failure to install
equipment to the relevant codes and manufacturer’s specifications shown in this section will
void the warranty.
Components having adjustments protected (e.g. paint sealed) by manufacturer are only to be
adjusted by an authorised service agent. They are not to be adjusted by the installation
person.
Unpacking
Remove all packaging and transit protection from appliance including all protective plastic coating
from door outer panel and exterior stainless steel panels.
Check equipment and parts for damage. Report any damage immediately to carrier and distributor.
Report any deficiencies to distributor who supplied appliance.
Check available gas supply is correct to as shown on rating plate located on inside of door.
Check the following parts have been supplied with the appliance:-
1. This appliance must be installed in a suitably ventilated room to prevent dangerous build up of
combustion products.
2. Installation must allow for a sufficient flow of fresh air for combustion air supply. Combustion air
requirements:
Combustion Air Requirements
All Gas Types 24 m³/hr minimum.
3. Position the appliance in its approximate working position.
4. All air for burner combustion is supplied from beneath appliance. Legs must always be fitted and no
obstructions placed beneath or around base of appliance, as obstructions will cause incorrect
operation and / or failure of appliance.
NOTE: Do not obstruct or block appliance flue. Never directly connect a ventilation system to
appliance flue outlet.
7
Installation
Clearances
NOTE:
Only non-combustible materials can be used in close proximity to this appliance.
To facilitate easy operation, drainage and servicing of appliance, a minimum of
600mm clearance should be maintained at front of appliance.
Any gas burning appliance requires adequate clearance and ventilation for optimum and trouble-free
operation. The following minimum installation clearances are to be adhered to:
Left / Right Hand Side 50mm. 0mm.
Rear 50mm. 0mm.
Combustible Surface Non Combustible Surface
Assembly
This model is delivered completely assembled. Ensure that the legs are securely attached.
NOTE:
This appliance is fitted with adjustable feet to enable it to be positioned securely and
level on uneven floors. This should be carried out on completion of gas connection.
Refer to 'Gas Connection Section'.
The rear leg housings on this appliance can also be fitted with rear rollers to enable
the appliance to be easily moved for positioning and cleaning purposes. If desired,
these rollers are supplied in the packaging, with appliance. See overleaf for fitting
instructions.
Optional Accessories (Refer to Replacement Parts List)
Plinth Kit. For installation details, refer to the instructions supplied with each kit.
8
Fitting Rear Rollers.
1. Raise the appliance from the floor by approx. 75mm
using suitable lifting equipment (i.e. Palletiser /
Forklift) to allow rear adjustable feet to be removed.
2. Unscrew and remove both rear adjustable feet from
rear leg housings.
3. Fit rear roller to rear leg housing and align screw
hole in side of rear leg housing with threaded hole in
rear roller.
4. Secure the rear roller to the leg support with bolt
supplied and tighten bolt.
5. Fit second roller and tighten securing bolt.
6. Lower appliance back to the floor and adjust front
adjustable feet to level appliance.
Appliance
Base
Installation
Fig 1
Rear Leg
Housing
Adjustable
Foot
Roller
Locating Bolt
Rear
Roller
9
Installation
Electrical Connection
NOTE: ALL ELECTRICAL CONNECTION MUST ON LY B E CARRIED OUT BY A QUALIFIED PERSON.
1. Each appliance should be connected to an adequately protected power supply and an isolation
switch mounted adjacent to, but not behind the appliance. This switch must be clearly marked and
readily accessible in case of fire.
2. Check electricity supply is correct as shown on Rating Plate attached to inside of access door.
3. For immediate electrical supply, simply plug the lead into a properly earthed, 3 pin socket.
Gas Connection
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY AN AU THORISED PERSON.
Flexible Hose Connection.
If a Gas Hose assembly is used to connect this appliance, hose and all fittings must have a minimum
¾” (Natural Gas) or ½” (LPG) inside bore diameter to ensure gas flow rate capacity required by this
appliance is achieved.
This must be verified by operating pressure testing at maximum gas supply demand condition.
Gas Hose assembly should also be classified for use in commercial kitchen conditions that appliance
will be used in.
Recommended Gas Hose Assembly Specification:
- AS/NZS 1869 Class B or D compliant or equivalent, that meets the following requirements:-
Class
B 7.0 kPa
D 2.6 MPa
Max Working Pressure
at 23 ± 2ºC
Working Temperature
Range
- 20ºC to + 125ºC
Resistance to Oil
Oil resistant lining and cover.
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED SERVICE PERSON.
1. It is essential that the gas supply is correct for the appliance being installed and that adequate
supply pressure and volume are available. Carry out the following checks before installation:a. Gas Type appliance has been supplied for is shown on
coloured stickers located above gas entry point and next to
rating plate. Check that this is correct for gas supply
appliance is being installed for. Gas conversion procedure is
shown in this manual.
b. Supply Pressure required for this appliance is shown in
Specifications section of this manual. Check gas supply to
ensure that adequate supply pressure exists.
Rating Plate
Location
c. Input Rate of this appliance is also shown on Rating Plate
fitted to inside of access door and in Specifications section
of this manual. Input rate should be checked against
available gas supply line capacity. Particular note should
be taken if appliance is being added to an existing
installation.
Fig 2
NOTE: It is important that adequately sized piping runs directly to connection joint on appliance,
with as few tees and elbows as possible to give maximum supply volume.
10
Loading...
+ 27 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.