Waldorf 800 Series RNB8910GE, 800 Series RNLB8910GEC, 800 Series RNB8910GEC, 800 Series RNLB8910GE, 800 Series RN8910GEC Installation And Operation Manual

...
Installation and Operation Manual
RN8910GE RN8910GEC
Gas Range Electric Static/Convection Ovens
Date Purchased
Dealer
Service Provider
232781-9
For use in GB & IE
RNL8910GE RNL8910GEC
RNB8910GE RNB8910GEC
RNLB8910GE RNLB8910GEC
The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless auth orized previously in writing by the manufacturer.
In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and design without prior notice.
© Copyright Moffat Ltd. November 2014.
MANUFACTURED BY
Moffat Limited
Christchurch New Zealand
INTERNATIONAL CONTACTS
AUSTRALIA
Moffat Pty Limited Web: www.moffat.com.au E.Mail: vsales@moffat.com.au Main Office: (tel) +61 (03) 9518 3888
(fax) +61 (03) 9518 3833
Service: (tel): 1800 622 216 Spares: (tel): 1800 337 963 Customer Service: (tel): 1800 335 315 (fax): 1800 350 281
CANADA
Serve Canada Web: www.servecanada.com E.Mail: info@servecanada.com Sales: (tel): 800 551 8795 (Toll Free) Service: (tel): 800 263 1455 (Toll Free)
NEW ZEALAND
Moffat Limited Web: www.moffat.co.nz E.Mail: sales@moffat.co.nz Main Office: (tel): 0800 663328
UNITED KINGDOM
Blue Seal Web: www.blue-seal.co.uk E.Mail: sales@blue-seal.co.uk Sales: (tel): +44 121 327 5575
(fax): +44 121 327 9711 Spares: (tel): +44 121 322 6640 (fax): +44 121 327 9201 Service: (tel): +44 121 322 6644 (fax): +44 121 327 6257
UNITED STATES
Moffat Web: www.moffat.com Sales: (tel): 800 551 8795 (Toll Free)
(tel): +1 336 661 1556 (fax): +1 336 661 9546 Service: (tel): 800 858 4477 (Toll Free) (tel): +1 336 661 1556 (fax): +1 336 661 1660
REST OF WORLD
Moffat Limited Web: www.moffat.co.nz E.Mail: export@moffat.co.nz
Contents List
Waldorf Gas Range Electric Static / Convection Ovens
RN(L)(B)8910GE Gas Range Electric Static Oven 900mm, 4 Burner. RN(L)(B)8910GEC Gas Range Electric Convection Oven 900mm, 4 Burner.
Introduction .............................................................................................. 2
Specification .............................................................................................. 3
Model Numbers Covered in this Specification General Gas Supply Requirements Gas Connection Electrical Supply Requirements Electrical Connection
Dimensions ................................................................................................ 7
Installation ................................................................................................ 8
Installation Requirements Unpacking Location Clearances Assembly Fitting Rear Rollers Gas Connection Electrical Connection Commissioning
Operation ................................................................................................. 13
Operation Guide Description of Controls Open Burners Oven
Cleaning and Maintenance ...................................................................... 16
Before Commencing Cleaning Open Burner Cleaning Oven Interior Cleaning Stainless Steel Surfaces
Fault Finding ............................................................................................ 18
Wiring Schematic .................................................................................... 19
Gas Conversion and Specifications ......................................................... 23
Conversion Procedure Gas Specifications
Replacement Parts List ............................................................................ 27
2
Introduction
We are confident that you will be delighted with your WALDORF GAS RANGE ELECTRICAL STATIC / CONVECTION OVEN and it will become a most valued appliance in your commercial kitchen.
To ensure you receive the utmost benefit from your new Waldorf appliance, there are two important things you can do.
Firstly:
Please read the instruction book carefully and follow the directions given. The time taken will be well spent.
Secondly:
If you are unsure of any aspect of the installation, instructions or performance of your appliance, contact your WALDORF dealer promptly. In many cases a phone call could answer your question.
CE Only:
These instructions are only valid if the country code appears on the appliance. If the code does not appear on the appliance, refer to the supplier of this appliance to obtain the technical instructions for adapting the appliance to the conditions for use in that country.
GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF
FIRE.
 T
HE APPLIANCE MUST NOT BE LEFT ON UNATTENDED.
 I
T IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO
ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED.
 DO NOT
STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER APPLIANCE.

DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
Warning

This appliance is for professional use and is only to be used by qualified persons.

Only authorised service persons are to carry out installation, servicing or gas conversion operations.

Components having adjustments protected (e.g. paint sealed) by the manufacturer should not be adjusted by the user / operator.

DO NOT operate the appliance without the legs supplied fitted.
Caution
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CA N CAUSE PROPERTY
DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE.
Warning
INSTRUCTIONS
TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT
LOCATION. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER.
Warning
3
Specifications
Model Numbers Covered in this Specification
RN[1]8910GE 4 Open Burners + Electric Static Oven. RN[1]8910GEC 4 Open Burners + Electric Convection Oven.
NOTE:
[1]: - Model Options;
- - Standard Models. L - Low Back Models. B - Bold Front. LB - Low Back and Bold Front.
[2] - Open Burner Options;
F - With Flame Failure Protection. PF - With Pilot and Flame Failure Protection.
General
A heavy duty, general purpose gas range created for compact modular kitchens. It is available on industrial adjustable feet or on robust rollers.
Open Burners are available in either 'PF' (Pilot and Flame Failure) or 'F' (Flame Failure Only) options. Open Burners are fitted with individual flame failure for each open burner. Easy clean stainless steel external finish.
4
Specifications
Gas Supply Requirements
- Australia:
- New Zealand:
- UK Only:
Category: II
2H3P
(20, 37).
Flue Type: A1.
* Measure burner operating pressure at manifold test point with two burners operating at full
setting. Operating pressure is ex-factory set through the appliance regulator and is not to be adjusted, apart from when carrying out gas conversion, if required. (Refer to ‘Gas Conversion’ section for details).
Natural Gas (G20) Propane (G31)
Open Burner (each) Open Burner (each)
Heat Input (nett)
Nominal 6.5 kW 6.5 kW Reduced 1.75 kW 1.75 kW
Gas Rate (nett)
Nominal 0.69 m3/hr 0.51 kg/hr Reduced 0.19 m3/hr 0.14 kg/hr
Supply Pressure
20 mbar 37 mbar
Burner Operating Pressure (*)
9.5 mbar 26 mbar
Gas Connection
3
/4” B.S.P. Male
Natural Gas LP Gas (Propane)
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa Burner Operating Pressure (*) 0.95 kPa 2.6 kPa Gas Connection
3
/4” B.S.P. Male
Natural Gas LP Gas
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa Burner Operating Pressure (*) 0.95 kPa 2.6 kPa Gas Connection
3
/4” B.S.P. Male
5
Specifications
- All Other Markets:
NOTE:
 (*) Measure Burner operating pressure at manifold test point with 2 burners operating at
'High Flame' setting.
 NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
 (**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
 Refer to ‘Gas Conversion and Specifications' section in this manual for further details.
Gas Connection
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand side, 32mm from rear and 655mm from floor and is reached from beneath appliance. (Refer to ‘Dimensions’ section).
Connection is ¾" BSP male thread.
Natural Gas Town Gas (**)
Input Rate (N.H.G.C.)
- each Open Burner
28MJ/hr 28MJ/hr
Supply Pressure 1.13 - 3.40kPa 0.75 - 1.50kPa Burner Operating Pressure (*) 0.95kPa 0.63 Pa Gas Connection See ‘Gas Connection’ information overleaf
LP Gas (Propane) Butane
Input Rate (N.H.G.C.)
- each Open Burner
28MJ/hr 28MJ/hr
Supply Pressure 2.75 - 4.50kPa 2.75 - 4.50kPa Burner Operating Pressure (*) 2.6kPa 2.6kPa Gas Connection See ‘Gas Connection’ information overleaf
6
Specifications
Electrical Supply Requirements
Electrical Connection
Electrical supply connection point is located at rear of appliance, approximately 80mm from right hand side, 466mm from rear and 150mm from floor.
When connecting this electric appliance to mains supply, ensure the following is carried out:-
 An isolating switch is fitted within 2m of appliance, but not on appliance and in such a position
that user does not have to reach across cooking surface.
 Supply cord shall be oil-resistant, sheathed flexible cable and not lighter than ordinary
polychloroprene or other equivalent synthetic elastomer sheathed cord (as per AS / NZS 3191 part 2.10.11. or IEC 60245-IEC-57) e.g. HO5 RN-F Type.
 Branch supply line shall be individually overload protected to correct current rating and supply
chord shall be protected against any mechanical or thermal damage.
 A grommet is fitted around wiring entry hole into appliance.  All wiring connections must be tight.
Refer to appropriate wiring standards for size of cable to be supplied to an appliance for current drawn on that line.
MODEL
1-Phase Connection
1P+N+E
230-240V
3-Phase Connection
3P+N+E
400-415V
RN8910GE
6.5 kW,
26.6 Amps @ 235 V
6.5 kW
L1 - 8.2 Amps L2 - 9.2 Amps L3 - 9.2 Amps
RN8910GEC
6.8 kW,
27.9 Amps @ 235 V
6.8 kW
L1 - 9.5 Amps L2 - 9.2 Amps L3 - 9.2 Amps
THIS APPLIANCE MUST BE EARTHED. IF SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY A SUITABLY
QUALIFIED PERSON IN ORDER TO AVOID A HAZARD.
Warning
7
Dimensions
RN(L)8910GE / GEC
Refer to Page 8 for Cook Top Options
8
Installation
Installation Requirements
NOTE:
 It is most important that this appliance is installed correctly and that operation is correct
before use. Installation shall comply with local electrical, gas, health and safety requirements.
 This appliance shall be installed with sufficient ventilation to prevent the occurrence of
unacceptable concentrations of health harmful substances in the room, the appliance is installed in.
Waldorf Gas Range Electrical Ovens are designed to provide years of satisfactory service, and correct installation is essential to achieve best performance, efficiency and trouble-free operation. This appliance must be installed in accordance with National installation codes and in addition, in accordance with relevant National / Local codes covering gas, electrical and fire safety.
Australia: - AS5601 - Gas Installations. New Zealand: - NZS5261 - Gas Installation. Australia / New Zealand: - AS / NZS3000 - Wiring Rules. United Kingdom: - Gas Safety (Installation & Use) Regulations 1998.
- BS6173 - Installation of Catering Appliances.
- BS5440 1 & 2 - Installation Flueing & Ventilation.
- BS7671 - Requirements for Electrical Installation.
Ireland: - IS 820 - Non - Domestic Gas Installations.
Installations must be carried out by qualified persons only. Failure to install equipment to relevant codes and manufacturer’s specifications shown in this section will void the warranty.
Components having adjustments protected (e.g. paint sealed) by manufacturer are only to be adjusted by an authorised service agent. They are not to be adjusted by the installation person.
Unpacking
 Remove all packaging and transit protection from appliance including all protective plastic coating
from exterior stainless steel panels.
 Check equipment and parts for damage. Report any damage immediately to carrier and
distributor.
 Report any deficiencies to distributor who supplied the appliance.  Check available gas and electrical supply is correct to as shown on rating plate located on front
right hand corner of bottom sill.
Location
1. Installation must allow for sufficient flow of fresh air for the combustion air supply.
2. Installation must include adequate ventilation means, to prevent dangerous build up of combustion products.
3. Never directly connect a ventilation system to appliance flue outlet.
4. Position appliance in its approximate working position.
5. All air for burner combustion is supplied from beneath appliance. Legs must always be fitted and no obstructions placed on underside or around base of appliance, as obstructions will cause incorrect operation and / or failure of appliance.
NOTE: Do not obstruct or block appliances flue. Never directly connect a ventilation system to
appliance flue outlet.
Combustion Air Requirements:
Natural Gas 29 m
3
/hr
LPG / Propane 30 m
3
/hr
Town Gas 29 m
3
/hr
Loading...