The W600 series provides reliable, flexible and
powerful control for your water treatment program.
Summary of Key Benets
Large touchscreen display with icon based programming makes setup easy
Universal sensor input provides extraordinary flexibility; the same controller can be used
with almost any type of sensor needed
Combination Sensor Input and Analog Input board that add even more flexibility
Lead/Lag control of up to 6 relays
Optional dual analog (4-20 mA) input for Fluorometers or nearly any other process value
Multiple language support allows simple setup no matter where your business takes you
Six control outputs allow the controller to be used in more applications
Economical wall-mount package for easy installation
On-screen and web page graphing of sensor values and control output status
Two Virtual Inputs that are calculated from two real inputs (cycles of concentration, % rejection, etc.)
The W600 with amperometric chlorine sensors can be used for reporting chlorine residual measurements in
accordance with EPA Method 334.0.
Complete flexibility in the function of each relay
• On/Off Setpoint
• Time Proportional Control
• Proportional Control (when purchased with 4-20mA or pulse solid state opto outputs)
• PID Control (when purchased with 4-20mA or pulse solid state opto outputs)
• In-Range or Out-of-Range activation
• Probe wash
• Timer-based activation
• Activation based upon the state of a contact closure
• Timed activation triggered by a Water Contactor or Paddlewheel flow meter’s accumulated total flow
• Activate with another output
• Activate as a percent of another output’s on-time
• Alarm
• Spike Set Point
• For Cooling Tower and Boiler applications:
• Biocide Timer
• Boiler blowdown on conductivity using intermittent sampling
Datalogging
Emailing Alarm messages, Datalog, Graph, or System Summary reports
Ethernet option for remote access via the Internet, LAN or Modbus/TCP
Page 2
Specifications
HPpH/ORP/Steel
Inputs
Power
100-240 VAC, 50 or 60 Hz, 7A max Fuse: 6.3 Amp
Sensor Input Signals (0, 1 or 2 depending on model code)
Contacting Conductivity: 0.01, 0.1, 1.0, or 10.0 cell constant, or
Electrodeless Conductivity (not available on the combination sensor/analog input card) or
Disinfection or
Amplified pH, ORP, or Ion Selective Electrode which requires a preamplified signal. ±5VDC power available for external
preamps. Walchem WEL or WDS series pH/ORP sensors recommended.
Each sensor input card contains a temperature input.
Temperature: 100 or 1000 ohm RTD, 10K or 100K Thermistor
Analog (4-20 mA) Sensor Input (0, 1, 2 or 4 depending on model code)
2-wire loop powered and self-powered transmitters supported
3-wire and 4-wire transmitters supported
Each dual sensor input board has two channels: Channel 1, 130 ohm input resistance and Channel 2, 280 ohm input resistance. The combination input board has one channel, 280 ohm input resistance.
Available Power: One independent isolated 24 VDC ±15% supply per channel. 1.5 W maximum for each channel.
2W (83 mA at 24 VDC) total power consumption for all channels (four total channels possible if two dual boards are
installed; 2W is equivalent to 2 Little Dipper sensors)
Digital Input Signals (6):
State-Type Digital Inputs
Electrical: Optically isolated and providing an electrically isolated 9V power with a nominal 2.3mA current when the digital
input switch is closed. Typical response time: < 2 seconds. Devices supported: Any isolated dry contact (i.e. relay, reed
switch). Types: Interlock
Low Speed Counter-Type Digital Inputs
Electrical: Optically isolated and providing an electrically isolated 9V power with a nominal 2.3mA current when the
digital input switch is closed, 0-10 Hz, 50 msec minimum width. Devices supported: Any device with isolated open
drain, open collector, transistor or reed switch.
Types: Contacting Flowmeter
High Speed Counter-Type Digital Inputs
Electrical: Optically isolated and providing an electrically isolated 9V power with a nominal 2.3mA current when the
digital input switch is closed, 0-500 Hz, 1.00 msec minimum width. Devices supported: Any device with isolated open
drain, open collector, transistor or reed switch. Types: Paddlewheel Flowmeter
Outputs
Powered Mechanical Relays (0 or 6 model code dependent)
Pre-powered on circuit board switching line voltage
All relays are fused together as one group, total current must not exceed 6A (resistive), 1/8 HP (93W)
Dry Contact Mechanical Relays (0, 2 or 4 model code dependent)
6 A (resistive), 1/8 HP (93W)
Dry contact relays are not fuse protected.
Pulse Outputs (0, 2 or 4 model code dependent)
Opto-isolated, solid-state relay, 200mA, 40V DC
VLOWMAX = 0.05V @ 18mA
4 - 20 mA (0 or 2 model code dependent)
Internally powered, Fully isolated
600 Ohm max resistive load, Resolution 0.0015% of span
Note: Conductivity ranges above apply at 25°C. At higher temperatures, the range is reduced per the range multiplier
chart.
Mechanical (Controller)
Enclosure Material Polycarbonate
Enclosure Rating NEMA 4X (IP65)
Dimensions 9.5 x 8 x 4” (241 x 203 x 102 mm)
Display 320 x 240 pixel monochrome backlit
display with touchscreen
Ambient Temperature -4 to 131°F (-20 to 55°C)
Storage Temperature -4 to 176°F (-20 to 80°C)
Note: For EN61000-4-6, EN61000-4-3 the controller met performance criteria B. This equipment is suitable for use in
establishments other than domestic and those directly connected to a low voltage (100-240 VAC) power supply
network which supplies buildings used for domestic purposes.
*Order disinfection sensor(s) separately
**Order disinfection sensor and WEL electrode and preamplifier housing or cooling tower
conductivity sensor separately
WCN CONDUCTIVITY SENSORS
NN
*Order conductivity sensor separately
Hardwired
Prewired with USA cords and pigtails
Prewired with DIN power cord, no pigtails
Hardwired
Prewired with USA cord and 2 pigtails
Prewired with DIN power cord, no pigtails
Hardwired
Prewired with USA cord and two 20 ft. pulse cables
Prewired with DIN power cord, no pigtails
Hardwired
Prewired with USA cord and four 20 ft. pulse cables
Prewired with DIN power cord, no pigtails
No sensor input cards
One sensor input card
Two sensor input cards
One sensor input card & one combination sensor/analog input card
One combination sensor/analog input card
One combination sensor/analog input card & one dual analog input card
Two combination sensor/analog cards
One dual analog input card
Two dual analog input cards
One sensor input card and one dual analog input card
ETHERNET
No analog outputs
One dual isolated
analog output card
No sensor
Boiler sensor with ATC, K=1.0, 250 psi, 20 ft. cable
Boiler sensor without ATC, K=1.0, 250 psi, 20 ft. cable
Condensate sensor with ATC, K=0.1, 200 psi, 10 ft. cable
Boiler sensor with ATC, K=10, 250 psi, 20 ft. cable
Two boiler sensors, with ATC, K=1.0, 250 psi, 20 ft. cables
Two boiler sensor without ATC, K=1.0, 250 psi, 20 ft. cables
Two condensate sensors with ATC, K=0.1, 200 psi, 10 ft. cables
Two Boiler sensors with ATC, K=10, 250 psi, 20 ft. cables
Boiler sensor with ATC, K=1.0 and boiler sensor without ATC,
K=1.0, 250 psi, 20 ft. cables
Boiler sensor with ATC, K=1.0 20 ft.cable and Condensate
sensor with ATC, K=0.1, 250 psi, 10 ft. cable
Boiler sensor with ATC, K=1.0 and Boiler sensor with ATC,
K=10, 250 psi, 20 ft. cables
Boiler sensor without ATC, 20 ft. and condensate sensor with
ATC, 10 ft. cable
Boiler sensor without ATC and Boiler sensor with ATC, K=10,
250 psi, 20 ft. cables
Condensate sensor with ATC, 10 ft. cable and Boiler sensor
with ATC, K=10, 250 psi, 20 ft. cable
No sensors or flow switch manifold
Single DIS manifold on panel*
DIS manifold plus pH/ORP/cooling tower cond tee on
panel**
Single DIS flow cell/cable, no sensor*
Two DIS flow cell/cable, no sensors*
No sensors or flow switch manifold*
Walchem, Iwaki America Inc. | Five Boynton Road Hopping Brook Park | Holliston, MA 01746 USA | Phone: 508-429-1110 www.walchem.com
RELAYS/WIRING
WCT600P CS N E - BI
N
No Ethernet
E
Ethernet card
M
Ethernet card with Modbus/TCP
Type of Input card
required
S or C for each sensor to be used
S or C
SS or CS
or CC
S or C
SS or CS
or CC
Example: WCT600PCSNE- BI
INPUT CARDSANALOG OUTPUTS
ETHERNET
WPH pH/ORP SENSORS
NN
No sensors or flow switch manifold
PN
Single low pressure manifold on panel**
QN
Single high pressure manifold on panel with 190783*
PX
Dual low pressure manifold on panel**
QX
Dual high pressure manifold on panel with two 190783*
*Order 102029 pH and/or 102963 ORP electrodes separately
**Order WEL electrode(s) and preamplifier housing(s) separately
WCT COOLING TOWER SENSORS
NN
No sensor
AN
Inline graphite contacting conductivity
BN
Graphite contacting conductivity + Flow Switch manifold on panel
CN
High pressure contacting conductivity
High pressure contacting conductivity + Flow Switch manifold
DN
on panel
EN
Inline 316SS contacting conductivity
FN
316SS contacting conductivity + Flow Switch manifold on panel
GN
Inline electrodeless conductivity
HN
Electrodeless conductivity + Flow Switch manifold on panel
Graphite contacting conductivity + Flow Switch manifold on panel
BA
+ Flat pH Cartridge no ATC
BB
+ Rod ORP Cartridge no ATC
BC
+ Flat ORP Cartridge no ATC
BD
+ Little Dipper
BH
+ Flat pH Cartridge no ATC + Little Dipper
BI
+ Rod ORP Cartridge no ATC + Little Dipper
BJ
+ Flat ORP Cartridge no ATC + Little Dipper
+ Little Dipper with Makeup graphite conductivity with
BK
threaded adapter
BQ
+ Pyxis
BR
+ WEL-PHF no ATC + Pyxis
BS
+ WEL-MVR no ATC + Pyxis
BT
+ WEL-MVF no ATC + Pyxis
+ Pyxis with Makeup graphite conductivity with threaded
BU
adapter
316SS contacting conductivity + Flow Switch manifold on panel
FA
+ Flat pH Cartridge no ATC
FB
S or C
High pressure contacting conductivity + Flow Switch manifold on panel
SS or CS or CC
+ Rod ORP Cartridge no ATC
FC
+ Flat ORP Cartridge no ATC
FD
+ Little Dipper
FH
+ Flat pH Cartridge no ATC + Little Dipper
+ Rod ORP Cartridge no ATC + Little Dipper
FJ
+ Flat ORP Cartridge no ATC + Little Dipper
FQ
+ Pyxis
FR
+ WEL-PHF no ATC + Pyxis
FS
+ WEL-MVR no ATC + Pyxis
FT
+ WEL-MVF no ATC + Pyxis
DE
+ pH &190783
DF
+ ORP & 190783
Electrodeless conductivity + Flow Switch manifold on panel
HA
+ Flat pH Cartridge no ATC
+ Rod ORP Cartridge no ATC
HC
+ Flat ORP Cartridge no ATC
HD
+ Little Dipper
HH
+ Flat pH Cartridge no ATC + Little Dipper
HI
+ Rod ORP Cartridge no ATC + Little Dipper
HJ
+ Flat ORP Cartridge no ATC + Little Dipper
+ Little Dipper with Makeup graphite conductivity with
HK
threaded adapter
HQ
+ Pyxis
HR
+ WEL-PHF no ATC + Pyxis
HS
+ WEL-MVR no ATC + Pyxis
HT
+ WEL-MVF no ATC + Pyxis
+ Pyxis with Makeup graphite conductivity with threaded
HU
adapter
180625.K September 2018
-
SENSORS
Type of Input card
required
S or C
SS or CS or CC
Type of Input card
required
S or C
S
SS, CS or
CC
SA or C
CS or CC
SA or C
CS or CC
CS or CC
CS or CC
CS or CC
SS, CS or
CC
SA or C
CS or CCFI
SA or C
CS or CC
CS or CC
CS or CC
SS, CS or
CC
SS or CSHB
SA or CS
CS
SA or CS
CS
CS
CS
CS