Walchem IX Specifications

Page 1
1000:1 Turndown Ratio
IX Series
A NEW CLASS OF ADVANCED METERING PUMPS
±1% High Accuracy
70% Energy Savings
High Compression Pump Head Design
Metering Pumps
Iwaki’s IX Series Metering Pumps
are digitally controlled direct-drive diaphragm pumps. Years of experience in high-end motor technology result in extremely accurate and energy efficient metering pumps with high resolution.
IX Series meets today’s demand for
IX Series pumps use efficient Brushless DC motors for speed control. High resolution motor control adjusts the discharge and suction speeds to meet a full and accurate turndown ratio up to 1000:1 and flowrates from 80 GPH (300 L/H) down to 0.02 GPH (7.5 mL/H).
Combined with precise motor control, an efficient valve design maintains accurate flow rates to allow a low-cost, mechanically-driven diaphragm pump to achieve a repeatability of ±1%.
Helical gears and return spring reduce power consumption by up to 70% compared to conventional mechanical diaphragm metering pumps.
A fixed stroke length and proprietary liquid end design maintains high compression during each stroke, resulting in fast priming and no gas-lock at any flow rate up to full rated pressures.
Page 2
Pump head PVDF
O ring TC: FKM
TE: EPDM
Diaphragm PTFE+PFA
Valve Alumina ceramic
Valve guide PVDF
Valve seat TC: FKM
TE: EPDM
Features
Suction vs. Discharge speed
• Suction speed remains constant. Discharge
speed reduces as pump is turned down, helping to reduce pulsation and inertial forces on piping.
Diaphragm
Standard Diaphragm Leak Sensor
rupture detector
Diaphragm
• Behind the diaphragm, a sensor monitors for any sign of rupture or leakage.
Faulty Operation Detection
• Abnormal operation detection protects the pump and piping during discharge pressure spikes (valve closure) or increases (clogging).
Note: In some instances, software may not be able to detect sudden increases in pressure due to a closed discharge. Installation of pressure relief/safety valve is always recommended.
Universal Design
• Multi-voltage operation (100-240VAC) and compliant to UL & CE standards
• Drive/control units each sealed to IP65 ratings
Flexible, User-friendly Interface
IX-B Series
• Customer controller positioning enables adjustment and setting of location on-site.
Drain
Rotates every
90 degrees
into 4 positions
• Flexible installation of the pump with built in wall bracket. * Patent Pending
(pump base turns into wall bracket)
4
3
2
1. Remove the pum p base
2. Attach p ump base to wall
3. Hang the pump to base
4. Lock it in place with clip
1
Swings two steps
on each side
Installation
on wall
Cavitation Prevention
• The suction speed can be manually lowered for operation with highly viscous liquids or prevention of cavitation.
“Foolproof” Valve Cartridge Design*
• An orientation guide in the suction or discharge ports prevents valve cartridges from being incorrrectly installed. * Except C060 and Stainless Steel versions.
Automatic Control
• Fully programmable analog or digital proportional control of the pump with Batch and Internal timer control features.
Degassing Assist
• Keypad operation or a contact signal (AUX) runs the pump at the full speed (overriding any mode) assisting in air elimination and priming.
Operation History
• The controller logs total power connect time, operation time, the number of strokes and the number of power-on cycles.
• 2-line LCD Display with LED backlight
• Multiple display languages
• Larger LED status bar for pump status visibility at distances or in dark locations.
IX-C and IX-D Series
• The controller position can be ordered in 6 positions for operator convenience.
• LCD display with LED backlight
• Multiple display languages.
• Bright LED for indication of pump status.
Top Back (TB type)
Top Left (TL type)
Top Right (TR type)
Left Face (LF type)
Top Front (TF type)
Right Face (RF type)
Page 3
Pump head PVDF
O ring TC: FKM
TE: EPDM
Diaphragm PTFE+PFA
Valve Alumina ceramic
Valve guide PVDF
Valve seat TC: FKM
TE: EPDM
Specifications
Model
IX- B 0 0 7 ( T C,TE )
Capacity Range
GPH (LPH)
0. 0 0 2-1.98
(0.0075 - 7.5)
Max Pressure
PSI (Mpa)
247*
(1.7 )
145 (1. 0 )
Average power
consumption
17W 0.4A
Current
Amps
Connection Size
Weight
lbs (Kg)
1/2" NPT 7.7 5 (3 . 5)
3/8" x 1/4" Tube 7.7 5 (3 . 5)
1/2" Flange 8.25 ( 3.7)
1/2" NPT 7.7 5 (3 . 5)
IX- B 015 ( T C,TE )
0.004 - 3.96 (0.015 - 15)
145
(1.0)
3/8" x 1/4" Tube 7.7 5 (3 . 5)
1/2" Flange 8.25 ( 3.7)
1/2" NPT 8.25 (3.7)
IX- B 0 3 0 ( T C,TE )
0.008 - 7.93
(0.03 - 30)
87*
(0.6)
19W
0.5A
1/2" x 3/8" Tube 8.25 ( 3.7)
1/2" Flange 8.60 (3.9)
1/2" NPT 8.25 (3.7)
IX-B045 (TC,TE)
0.012 - 11.89 (0.045 - 45)
58*
(0.4)
1/2" x 3/8" Tube 8.25 ( 3.7)
1/2" Flange 8.60 (3.9)
IX-C060TC / TE
IX-C060S6
IX-C150TC / TE
IX-C150S6 31 (14.1)
IX-D150TC / TE
IX-D150S6 33.0 (15.0)
IX-D300TC / TE
IX-D300S6 37.4 (17.0)
0.02 - 15.8 (0.08 - 60)
0.05 - 39.6 (0.2 - 150)
0.05 - 39.6 (0.2 - 150)
0.1 - 79.2
(0.4 - 300)
145
(1.0)
62W 0.8 A
58
(0.4)
145
(1.0)
110W 1.3A
73
(0.5)
1/2” NPT
1/2” Flange
3/4” NPT
3/4” Flange
3/4” NPT
3/4” Flange
1” NPT
1” Flange
23 (10.5)
29 (13.2)
23 (10.5)
31.9 (14.5)
34.1 (15.5)
*CAUTION: Pump may be capable of higher pressure than tubing. Operate pumps at pressures lower than tubing specifications.
NOTES:
Maximum discharge capacity is rated with clean water at ambient temperature at maximum discharge pressure. Output may increase as pressure decreases.
Accuracy is not guaranteed at flows below 0.5GPH (2 LPH) for IX-D300S6, 0.26GPH (1 LPH) for IX-C150S6 or 0.11GPH (0.4 LPH) for IX-C060S6.
Maximum viscosity: IX-B: 100/500 cps IX-C: 1000 cps IX-D: 300 cps (standard pumps - consult factory for higher viscosities).
Outputs may be reduced.
Liquid temperature range: 0 -50°C (TC, TE type), 0-80°C (S6 type). No viscosity change. Non freezing. No slurry.
Operating temperature range: 0-50°C (Indoor use only)
Operating humidity range: 30-90% RH (Non-condensing in the controller)
Maximum dry suction lift rating is 6.5 ft. (2m).
Pumps should always be shielded from direct exposure to the elements.
Materials of Construction
O-ring TC: FKM
TE: EPDM
Pump head PVDF
O-ring TC: FKM
TE: EPDM
Valve seat TC: FKM
IX-C/D
Diaphragm
PTFE+EPDM
Valve
Alumina
ceramic
Valve guide
PVDF
TC, TE Materials
IX-B
Pump head SUS316
Valve gasket PTFE
Valve seat SUS316
S6 Materials
Valve
SUS316
Diaphragm
PTFE+EPDM
Valve guide
SUS316
Page 4
1000:1 Turndown Ratio
Controller Specifications
A NEW CLASS OF ADVANCED METERING PUMPS
±1% High Accuracy
70% Energy Savings
High Compression Pump Head Design
IX - C150 TC N - TB - U
1 2 3 4 5
IX SERIES
1 DRIVE UNIT/PUMP SIZE B007: 1.98 GPH (7.5 LPH) B015: 3.96 GPH (15 LPH) B030: 7.90 GPH (30 LPH) B045: 11.80 GPH (45 LPH) C060: 15.8 GPH (60 LPH) C150: 39.6 GPH (150 LPH) D150: 39.6 GPH (150 LPH) D300: 79.2 GPH (300 LPH)
2 WET END MATERIALS TC = PVDF/FKM/CE TE = PVDF/EPDM/CE
Ordering Information
S6 = 316SS/PTFE
C & D ONLY
3 CONNECTIONS T = Tubing Connection
IBX ONLY
N = NPTM FA = Flange (ANSI 150 lb)
4 CONTROLLER LOCATION IX-C/D Only; Leave Blank for IX-B TB = Top Back TF = Top Front TR = Top Right TL = Top Left RF = Right Face* LF = Left Face* * No display cover on IX-C
5 POWER CORD U = USA (115V) 2 = USA (230V) E = Europe (220V DIN)
Safety Certifications
The IX series metering pumps are tested by Intertek to UL and CSA standards.
Operation mode
Monitors
Operation Keypad
Control function
Input
Output
Power voltage
No te1: Volum e per pul se is prog ramma ble in the P ulse, Batch or Inter val Batch operation mode s. The min imum pu mp outou t is the vol ume per o ne
stro ke of the pump (corre cted with c alibration). The increment s ettin gs are als o a factor of the volume per stroke of t he pump (co rrecte d with calibrati on).
Note2: Pump ca n be prog ramme d to STOP or START with i nput co ntact.
Note3: The m ax volt age and c urrent applie d to the inpu t conta ct is 12 VDC and 5m A. If a relay is used, the min appl icable l oad must b e 5mA or less.
Note4: When B atch Complete (batch operation comp lete outp ut sign al) is set to EN ABLE, all other fu nctions will be s et to DISAB LE by defau lt.
Note5: When Volume Prop. PLS outpu t is set to ENA BLE, all ot her fun ctions w ill be set to DISABLE by default.
Note6: Do not o perate pu mp outside of the sp ecifi ed volta ge rang e to avoid da mage. The m in to max v oltage r ange limits are 9 0-264VAC.
Note7: The Pressure at which th e Motor Ove rload a larm tr iggers is appr oximatel y 1.3 to 2 times the rate d maximum disc harge p ressur e.
Note8: Whe n using Pr ofiBus c ommun icatio n, a separa te ProfiBu s Conver sion Box ( Access ory) a nd conn ectors a re requir ed.
Optional Accessories
1 2 3
MAN (Manual)
ANALOG fixed control ANALOG variable con­trol
Pulse control
EXT
Batch control
Interval batch control-
Not e1
Profibus control
LCD
LED
STOP PRIME Keylock Interlock AUX Maximum discharge rate Buffer memory Analog input display STOP/Pre-Stop/AUX/Interlock Analog
Pulse
Alarm1 (OUT1)
Alarm2 (OUT2)
Power supply Current
Note6
Not e1
Not e1
Note8
Use the UP ( ) a nd DOWN ( ) key s to adjus t a flow rate.
4-20mA, 0-20 mA, 20 -4m A, 20- 0mA ( Prop ortional to the fl ow rate )
2-setpoint programmable (0-20mA, proportional to flow rate)
IX-B 00 7: 0.000 625mL /PLS - 15.0mL/ PLS IX- C0 60 : 0.00625mL /PLS - 120mL/ PLS
IX-B 015 : 0.001250 mL/ PLS - 30.0mL /PLS IX- C15 0: 0.0156mL /PLS - 30 0mL/PLS
IX-B 03 0 : 0.002500 mL/PL S - 60.0mL /PLS I X- D 15 0 : 0.0156mL /PLS - 300mL/PLS
IX-B 04 5 : 0.003750mL/PLS - 90.0mL /PLS IX-D3 00 : 0.0312mL/PLS - 6 00mL /PLS
IX-B 00 7: 0.625 mL/ PLS - 15.0L /PLS IX-C 06 0: 6.25mL/PLS - 120L/ PLS
IX-B 015 : 1.250mL/ PLS - 30.0 L/PLS IX- C150 : 15.6mL/PL S - 300L /PLS
IX-B 03 0 : 2.500 mL/ PLS - 60.0L/ PLS IX-D 150 : 15.6mL/PLS - 3 00L /PLS
IX-B 04 5 : 3.750mL /PLS - 90.0L /PLS IX- D30 0: 31.2mL/ PLS - 60 0L/ PLS
Day: 0 - 9, Hou r: 0 - 23, Minute: 1 - 59
Same flow r anges a s Batch control.
Communication protocol: Profibus-DP-compliant
International standard: EN50170 (IEC61158)
16 digits × 2 lines, backlit character LCD
WHITE: Pump stopped/waiting. ORANGE: Running, Pre-Stop condition. GREEN: Pump operating. RED: Alarm condition/stopped.
( )Start /Stop, M ENU, ESC, ( ) Enter, ( )Up, ( )Down, ( )L eft an d ( )Right keys
Operation stops/starts with input contact
Forces m ax. sp eed operatio n by pres sing the ( ) UP and ( )DOW N keys
Locks/unlocks keypad operation with PIN code
Operation stops/starts with input contact
Pump ope rates at programmed flow rate with input co ntact
Adjust s maxi mum flow rate limit of p ump (all opera tion mo des)
Enables memory or ignoring of incoming pulses during operation in Batch mode
Displays the actual ana log input value
No-voltage contact or open collecto r
0-20m A DC (Interna l resis tance i s 200Ω)
No-voltage contact or open collecto r. Max pulse frequency: 100 Hz (Pulse ON: 5 mS+) No-voltage contact (mechanical relay): 250VAC 2A (Resistive load) Possib le outpu t condi tions can be Enab led /Dis abled : STOP / Pre-Stop / Interl ock / Lea k Detection / Moto r Overlo ad Factor y prese t: Lea k Detec tion is En abled for OUT1 No-voltage contact (PhotoMOS relay): AC/DC 24V 0.1A (Resistive load) Possib le outpu t condi tions can be Enab led /Dis abled : STOP / Pre-Stop / Interlock Leak De tectio n / Motor Ove rload Volume Prob. PLS Factor y prese t: Inte rlock i s Enabled for OUT 2
12VDC 30m A maximum
DC 0-20 mA, 2 pr ogram mable s etpoin ts (Max. res istan ce load : 300Ω)
100 -240 VAC 10 % 50 /6 0H z
Note5
+
_
Note2
Note2
Note3
Note7
Note7
/ Batch Complete
/ Batch Complete
Note4
/ Drive Er ror /
Outputs (3/6)
Note4
/ Drive Er ror
Control Input (1/4)
STOP/PRE-STOP Input (2/5)
AUX In/ANA Out (2/5)
Communication (1/4)
4
About Us
For more information on the entire Iwaki America product line, visit:
iwakiamerica.com
1. DIN 5-Pin Field-wired Control Input connector (ANA/DIG/Batch). P/N E90495 (Supplied w/Pumps)
2. DIN 5-Pin Reverse-key Field-wired connectors (Stop/Aux/ANA Out). P/N E90496
3. DIN 4-Pin Field-wired mini-square Output connectors (OUT1/OUT2) P/N E90497
4. DIN 5-Pin Control Input connector & 5m Cable (ANA/DIG/Batch) P/N IX0018
5. DIN 5-Pin Reverse-key connector & 5m Cable (Stop/Aux/ANA Out) P/N IX0019
6. DIN 4-Pin mini square Output connectors & 5m Cable (OUT1/OUT2) P/N IX0020
7. ProfiBus Converter Box for communication interface (IX0018 req’d) P/N PB-01
5
6 7
Power cord
180452.O September 2018