Waeco CombiPower 2012, CombiPower 2024 Operating Manual

Page 1
CombiPower
2012, 2024
DE 5 Sinus-Wechselrichter mit integriertem
Automatiklader
Bedienungsanleitung
EN 35 Sine wave inverter with integrated
automatic charger
Operating manual
automatique intégré
Notice d’utilisation
ES 94 Inversor senoidal con cargador
automático integrado
Instrucciones de uso
IT 124 Inverter sinusoidale con caricatore
automatico integrato
Istruzioni per l’uso
Page 2
D
Fordern Sie weitere Informationen zur umfangreichen Produktpalette aus dem Hause Dometic WAECO an. Bestellen Sie einfach unsere Kataloge kostenlos und unver­bindlich unter der Internetadresse: www.dometic-waeco.de
GB
We will be happy to provide you with further information about Dometic WAECO products. Please order our free catalogue with no obligation to buy on our homepage: www.dometic-waeco.com
F
Demandez d’autres informations relatives à la large gamme de produits de la maison Dometic WAECO. Commandez tout simplement notre catalogue gratuitement et sans engagement à l’adresse internet suivante : www.dometic-waeco.com
E
Solicite más información sobre la amplia gama de productos de la empresa Dometic WAECO. Solicite simplemente nuestros catálogos de forma gratuita y sin compromi­so en la dirección de Internet: www.dometic-waeco.com
I
Per ottenere maggiori informazioni sull’ampia gamma di prodotti Dometic WAECO è possibile ordinare una copia gratuita e non vincolante del nostro Catalogo all’indirizzo Internet: www.dometic-waeco.com
NL
Maak kennis met het omvangrijke productscala van de firma Dometic WAECO. Bestel onze catalogus gratis en vrijblijvend onder het internetadres: www.dometic-waeco.com
DK
Bestil yderligere information om det omfattende produktudvalg fra Dometic WAECO. Bestil vores katalog gratis og uforpligtende på internetadressen: www.dometic-waeco.com
S
Inhämta mer information om den omfattande produktpaletten från Dometic WAECO: Beställ våra kataloger gratis och utan förpliktelser under vår Internetadress: www.dometic-waeco.com
N
Be om mer informasjon om det rikholdige produktutvalget fra Dometic WAECO. Bestill vår katalog gratis uforbindtlig på Internettadressen: www.dometic-waeco.com
FIN
Pyytäkää lisää tietoja Dometic WAECOn kattavista tuotevalikoimista. Tilatkaa tuoteku­vastomme maksutta ja sitoumuksetta internet-osoitteesta: www.dometic-waeco.com
Page 3
CombiPower
1
2
17
16
1 2 3 4 5 6
15
7
8
91011121314
3
Page 4
3
Ii:5.0 FQ:50
Vi:230 W:1150
WAECO COMBO
CombiPower
1
10
9 8
7
4
Ig=XX.X Vg=XXX.X FQ=XX.X W=XXX
AC GRD
INVERTER
CHARGER
ALARM
56
Ib=XXX °C = XX.X Vb=XX.X
ON / OFF
2
34
Ii=XX.X Vi=XXX.X FQ=XX.X W= XX.X
Change
Run Mode
COMBI
Power On
Power On
4
CHR
Another
Param
Input
Password
Iac
Setup
P.S. Mode
Param
Power
Sharing
Page 5
CombiPower
Please read this manual carefully before installing and using the device, and keep it in a safe place. If you sell the device, pass on this instruction manual to the buyer.
Table of contents
1 Notes on using the instruction manual. . . . . . . . . . . . . . . . . . . . . . . 36
2 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
3 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
4 Technical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
5 Switching the device on and off . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
6 Configuring the device with the remote control . . . . . . . . . . . . . . . . 49
7 Maintaining and cleaning the device . . . . . . . . . . . . . . . . . . . . . . . . 57
8 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
9 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
10 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
11 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
EN
35
Page 6
Notes on using the instruction manual CombiPower
1 Notes on using the instruction manual
DANGER! Safety instruction: Failure to observe this instruction will cause
D ! !
A
fatal or serious injury.
WARNING! Safety instruction: Failure to observe this instruction can cause
fatal or serious injury.
CAUTION! Safety instruction: Failure to observe this instruction can lead to
injury.
NOTICE!
Failure to observe this instruction can cause material damage and impair the function of the product.
NOTE
Supplementary information for operating the product.
I
Action: This symbol indicates that action is required on your part. The
required action is described step-by-step.
This symbol describes the result of an action.
fig. 1 5, page 3: This refers to an element in an illustration. In this case, item 5 in figure 1 on page 3.
Please observe the following safety instructions.
36
EN
Page 7
CombiPower General safety instructions
2 General safety instructions
The manufacturer will not be held liable for claims for damage resulting from the following:
z Faulty assembly or connection z Damage to the product resulting from mechanical influences and excess
voltage
z Alterations to the product without express permission from the manu-
facturer
z Use for purposes other than those described in the operating manual
2.1 General safety
DANGER!
D
!
z Before you use the device for the first time, check that the
operating voltage matches the mains voltage (see type plate).
z In the event of fire, use a fire extinguisher which is suitable for
electrical devices.
WARNING!
z Do not use the device if the device itself or its connection cables
are visibly damaged.
z This device may only be repaired by qualified personnel. Inade-
quate repairs may cause serious hazards. Should your device need to be repaired, please contact custom­er services.
z Persons whose physical sensory or mental capacities prevent
them from using this device safely should not operate it without the supervision of a responsible adult.
z Electrical devices are not toys.
Always keep and use the device out of the reach of children.
z Children must be supervised to ensure that they do not play with
the device.
z If a battery is connected, the device is live, even if the main
switch is turned off.
EN
37
Page 8
General safety instructions CombiPower
CAUTION!
!
A
2.2 Operating the device safely
z Disconnect the device from the mains:
Before working on the device – Before cleaning and maintenance – After use
NOTICE!
z Check that the voltage specification on the type plate is the
same as that of the power supply.
z Ensure that other objects cannot cause a short circuit at the
contacts of the device.
z Ensure that the red and black terminals never come into
contact.
z Do not pull on the cables. z Never pull the plug out of the socket by the cable.
! !
A
WARNING!
z Before starting the consumer devices, make sure that the power
supply line and the plug are dry.
CAUTION!
z Even after the fuse triggers, parts of the inverter remain live. z Do not disconnect any cables when the device is still in use.
NOTICE!
z Never expose the device to moisture. z Make sure that none of the air inlets and outlets are blocked. If
necessary, clean the vents before you use the device.
z Ensure good ventilation. z Do not connect the 230 V output of the inverter to a different
230 V source.
38
EN
Page 9
CombiPower General safety instructions
2.3 Safety precautions when handling batteries
WARNING!
!
!
A
z Batteries contain aggressive and caustic acids. Avoid battery
fluid coming into contact with your body. If your skin does come into contact with battery fluid, wash the part of your body in question thoroughly with water.
CAUTION!
z Do not smoke and ensure that no sparks can arise in the vicinity
of the engine or battery.
NOTICE!
z Only use rechargeable batteries. z Make sure the polarity is correct when connecting the battery:
Red terminal – positive battery terminal – Black terminal – negative battery terminal
z Prevent any metal parts from falling on the battery. This can
cause sparks or short-circuit the battery and other electrical parts.
z Follow the instructions of the battery manufacturer and those of
the manufacturer of the system or vehicle in which the battery is used.
z Never attempt to charge frozen batteries. z If you need to remove the battery, first disconnect the earth
connection. Disconnect all connections and all consumers from the battery before removing it.
EN
39
Page 10
Intended use CombiPower
3 Intended use
Sine wave inverters with integrated automatic chargers are designed to convert 12 V or 24 V DC voltage to 230 V AC voltage with a frequency of 50 Hz, as well as to charge the following batteries:
z Lead automotive batteries z Lead gel batteries z Maintenance-free batteries z Absorbed glass mat (AGM) batteries
Never use the devices to charge other battery types (such as NiCd or NiMH).
WARNING! Do not use the device to power medical equipment.
! !
WARNING! Danger of explosions
Do not charge batteries with a cell short circuit. The oxyhydrogen they produce can cause explosions. Do not charge nickel cadmium and non-rechargeable batteries with the charger. The cases of these batteries can burst explosively.
40
EN
Page 11
CombiPower Technical description
4 Technical description
4.1 General description
The sine wave inverter with integrated automatic charger is a combination of two devices:
z Battery charger z Sine wave inverter
The device can be used as follows:
z As an automatic charger (6-stage charging characteristic) z As a sine wave inverter: the device produces a pure 230 V output voltage z Power sharing: the device powers a connected load with 230 V and simul-
taneously charges a battery
z Generator function (mains voltage function): the device supports a 230 V
mains voltage by supplementing it with energy from a battery (common power source)
z Power support (PSF): the device supports a 230 V mains voltage with
energy from a battery by powering some of the loads from the battery and the others from the 230 V mains supply (separate power sources)
z Uninterruptible power supply (UPS): the device powers connected loads
from a battery when the mains supply fails
The device has the following protective systems:
z DC low voltage shutdown z DC overvoltage shutdown z Overheating protection z Overload protection
The device is operated using a remote control.
EN
41
Page 12
Technical description CombiPower
4.2 Connections and controls
No. in
fig. 1,
page 3
1 POS (+) Positive terminal
2 NEG (–) Negative terminal
Designation Explanation/function
3 5A CHARGER/
2.5A CHARGER
4 INV. AC OUTPUT 230 V inverter output
5 A/2.5 A charger connection
z L: Live conductor
z N: Neutral conductor z FG: Earth connection
5 AC OUTPUT 230 V output
z L: Live conductor
z N: Neutral conductor z FG: Earth connection
6 AC INPUT 230 V input
z L: Live conductor
z N: Neutral conductor z FG: Earth connection
7 Cover
8 CIRCUIT
BREAKER
9 CHASSIS
GROUND
10 Main switch:
42
LS: Circuit breaker The circuit breaker is triggered when there is
excess current or a short circuit.
Eliminate the cause of the fault.Press the switch to reset the device.
Earth connection
z 0: Off z I: On
The main switch overrides the remote control set­tings. When the main switch is in the “0” position, you cannot switch on the device with the remote control.
EN
Page 13
CombiPower Technical description
No. in
fig. 1,
page 3
11 CAN2 CAN bus connection
12 CAN1 CAN bus connection
13 LCM Remote control connection
14 RS-232 Serial RS-232 port for connecting to a PC
15 BAT. TEMP. Battery sensor connection
16 FAILURE Connection for fault indicator relay
17 INV CHR Connection for external switch
Designation Explanation/function
EN
43
Page 14
Technical description CombiPower
4.3 Remote control
No. in
fig. 3,
page 4
1 Display: Shows operating messages or settings
2 ON/OFF To switch on the device: press briefly
3 Scroll through menu (level up; vertical scroll)
4 Hold down (> 2 s): open setup menu
5 Scroll through menu (back; horizontal scroll) or
Symbol Explanation/function
To switch off the device: hold down (> 3 s)
Press briefly: scroll through menu (level down; vertical scroll) or confirm value (ENTER function)
select a value
6 Scroll through menu (forward; horizontal scroll) or
select a value
7 ALARM LED for alarm display
z Red light: 230 V over/undervoltage alarm, 12 V
over/undervoltage alarm, overload or fan mal­function
8 CHARGER Charging status LED:
z Green light: charging z Off: not charging
9 INVERTER Inverter status LED:
z Green light: inverter mode z Red light: inverter fault z Off: inverter mode off
10 AC GRID Mains voltage status LED:
z Green light: AC voltage at input
z Off: no AC voltage at input
44
EN
Page 15
CombiPower Technical description
4.4 Status displays
The status displays on the remote control (fig. 3 1, page 4) show the current device parameters. Use the “ displays (fig. 4, page 4).
Symbol Explanation
Ib Battery current
Ig Generator current
Ii Inverter current
Vb Battery voltage
Vg Generator voltage
Vi Inverter voltage
FQ Frequency (Hz)
” and “” buttons to switch between the
W Power (watts)
°C Battery temperature
Main battery charging phase
z : battery not charging z : I phase active z : U0 phase active z : U phase active
EN
45
Page 16
Technical description CombiPower
4.5 Battery charging function
The charging characteristics are referred to as modified IU0U characteristics.
U/V
I/A
1
23 54
6
U
I
100 %
U0 U
6 %
I
t
1: Analysis phase
First, the battery charge is analysed with increasing charge current.
2: I phase (bulk)
At the beginning of the charging process, the flat battery is charged with a constant current (100% charge current) until the battery voltage reaches
14.4 V or 28.8 V. The charging current decreases when the battery has reached this charging level.
3, 4: U0 phase (absorption)
Now the two-stage absorption charging process (U0-Phase) begins, where the charge voltage and duration depend on the size and type of the battery. Different voltages can be set for phases 3 and 4, which remain constant until the maximum charging current (6% of the set current) is reached.
Phase 4 ends no later than 8 hours after 13.8 V or 27.6 V is reached.
46
EN
Page 17
CombiPower Technical description
5: U Phase (floating)
The U phase serves to maintain the battery capacity (100%).
If DC loads are connected, they are powered by the device. Only if the power required exceeds the capacity of the device is this surplus power provided by the battery. The battery is then discharged until the device re-enters the I phase and charges the battery.
6: 14-day conditioning
Every 14 days, the battery charger switches back to phase 2 in order to revive the battery. This prevents any fatigue symptoms such as sulphation.
4.6 5 A/2.5 A charger (second battery connection)
The device has a connection for a second battery (3-step charger). You can charge a small battery (such as an automotive battery) using this connection.
The charging voltage is 14.4 V or 28.8 V. The maximum charging current is 5A or 2.5A.
4.7 Inverter function
In inverter mode, the device supplies a regulated 230 V voltage.
The maximum constant output is 2000 W. Do not connect any devices with a higher power rating. If you connect several devices, make sure their total power rating does not exceed 2000 W.
NOTE
Note when connecting devices with an electrical drive (such as
I
An adjustable energy saving mode protects the battery. It regularly checks whether battery power needs to be used. If not, the function is deactivated and no idle current is used.
power drills, refrigerators and switched-mode power supply), that they often need more power than is stated on the type plate.
EN
47
Page 18
Switching the device on and off CombiPower
4.8 Connections
A battery is connected to the positive and negative terminals. A 230 V power source can be connected to the “AC INPUT” input (fig. 1 6, page 3). The power supply via “AC INPUT” takes precedence over the battery power supply, so that the battery is not discharged unnecessarily.
Voltage is present at the outputs under the following conditions: z “INV. AC OUTPUT” (fig. 1 4, page 3)
A battery is connected – A 230 V power source is connected – A battery and a 230 V power source are connected
(The battery is charged when the consumer devices do not require all the power)
z “AC OUTPUT” (fig. 1 5, page 3)
A 230 V power source is connected
5 Switching the device on and off
NOTE
The main switch (fig. 1 10, page 3) on the device must be in the
I
Press the “ON/OFF” button (fig. 3 2, page 4) on the remote control.
The device is switched on and the message “System Initialisation …”
appears in the display.
After a few seconds, the display shows the message “System startup
please wait…”.
The system status is checked.
After 5 to 10 seconds, the display is ready and shows the status of the
device: – The device is ready for use: the display shows operating parameters. – Alarm messages are present: undervoltage, overload, fan failure,
Faults have occurred: undervoltage (UVP), overvoltage (OVP), over-
“I” position.
overtemperature
temperature (OTP), overload (OLP)
48
EN
Page 19
CombiPower Configuring the device with the remote control
6 Configuring the device with the
remote control
6.1 Overview of parameters
NOTE
I
z For the menu and parameter structure, see fig. 4, page 4. z Access to the “Another Param” menu is password-protected.
This menu can only be accessed by technicians.
“Change Run Mode” menu (operating mode)
Parameter Explanation
COMBI Power On The device acts as a charger and, if necessary, as an
inverter if there is not sufficient current at the AC input.
CHR Power On The device only acts as a charger. The inverter function is
deactivated.
“P.S. Mode Param” menu (power sharing mode)
Parameter Explanation Value range Default
Iac setup Power sharing level: limits the cur-
rent at the 230 V input (overload protection).
3 A – 25 A 3 A
Power Sharing
Determines the power sharing mode: Disable = deactivated GEN. = generator function SUPP. = support function SHAR. = power sharing
“SHAR.” enables the power sharing function.
“SHAR. GEN.” enables the power sharing and generator functions.
“SHAR. SUPP.” enables the power sharing and support functions.
“SHAR. SUPP. GEN.” enables the power sharing, support and genera­tor functions.
EN
Disable
SHAR. SHAR. GEN. SHAR. SUPP. SHAR. SUPP. GEN.
Disable
49
Page 20
Configuring the device with the remote control CombiPower
6.2 Enabling functions
The device supports the functions described below.
Power sharing function
If the load from the connected consumer devices and the battery charging current is higher than the connected 230 V power source, the fuse of the power source would normally blow. In power sharing mode, the device reduces the battery charging current and thus increases the power available for connected consumers.
The power sharing level (current at the 230 V input) can be configured using the remote control. If must be adapted to the fuse of the power source. For example, if it has a 10 A fuse, the power sharing level must also be 10 A (see chapter “Limiting the input current at the 230 V input (power sharing level)” on page 56).
Example:
INV. AC
OUTPUT
A
M
4
2
12/24 V
X
-
+
230 V
P OS
[+ ]
I N V
C H R
B N B
D E N
N
B E
NEG
G
N
B
F
A
E
N
I
B
L U
E
A
R
E
T .
T
[-]
O
E
.
M
N
M
P
O
.
C
C : W
IN
IN
V
E
V
R
.
A
TO
R
O
C
S
U
R
-2
T
3
P
2
U T
L L C
FG
M
5 0
A
A
N
M
C
C
A
A
O
X
N
U
1
O
T P
F
U
F
L
C
T
A
C
N
F
H
2
GL
5
A
0
R
A
G
M
A
E
A
C
R
X
I
N T
P U
T F G
N
C H
A S
G
S
R
I
S O U
N
D
AC OUTPUT
AC INPUT
230 V
50
EN
Page 21
CombiPower Configuring the device with the remote control
Generator function (external mains power supply)
NOTICE!
Observe the standards that apply in your country to the generator
A
function.
If the load current is greater than the fuse of the connected 230 V power source, the fuse would normally blow. The generator function enables the device to provide additional power, which it takes from the battery.
If the required power falls below the power sharing level (see chapter “Limit­ing the input current at the 230 V input (power sharing level)” on page 56), the device recharges the battery.
In generator mode, the 230 V power source and the battery act as a common power source.
Example:
INV. AC
OUTPUT
X
A
M
4
2
12/24 V
-
+
230 V
P
OS
[+
]
I N
V C H
R
B N
B D
E
N N B E
NEG
G N
B
F A
E
N
I
B
L
U
E
A
R E
T .
T
[-]
O
E
.
M
N
M
P
O
.
C
C : W
IN
IN V E
V
R
. A
TO
R
O
C
S
U
R
-2 T
3
P
2
U
T
L L C
F
M
G
5 0
A
A
N
M
C
C
A
A
O
X
N
U
1
O
T P
F
U
F
L
C
T
A
C
N
F
H
2
GL
5
A
0
R
A
G
M
A
E
A
C
R
X
I
N T
PUT
F G
N
C
H
A S
G
S
R
I
S O U
N
D
AC OUTPUT
AC INPUT
230 V
EN
51
Page 22
Configuring the device with the remote control CombiPower
Power support function
If the generator function is not permitted by the standards in your country because the device operates in parallel to the 230 V mains, you can use the support function. The “AC OUTPUT” and “INV. AC OUTPUT” outputs are electrically isolated from each other.
The 230 V power source provides voltage at “AC OUTPUT” while the battery supplies “INV. AC OUTPUT”.
If the devices connected to “INV. AC OUTPUT” require more current than the battery can deliver, they are switched off. If the devices connected to “AC OUTPUT” require more current than the set power sharing level (see chapter “Limiting the input current at the 230 V input (power sharing level)” on page 56; it must correspond to the fuse rating of the 230 V power source), the fuse of the 230 V power source blows. For example, if the power supply at a camp site has a 10 A fuse but the consumer devices required 16 A, the camp site fuse blows.
Example:
INV. AC
OUTPUT
A
M
4
2
12/24 V
X
-
+
PO
S[+]
I N
V C H
R
B N
B D
E
N N B E
NE
G N
B
F A
E
N
I
B
L
U
E
A
R
G[-]
E
T .
T
O
E
.
M
N
M
P
O
.
C
C :
W
IN
I
V
N
E
V
R
. A
TO
R
O
C
S
U R
­2
T
3
P
2
U
T
L L C
F
M
G
5 0
A
A
N
M
C
C
A
A
X
O
N
U
1
O
T P
F
U
F
L
C
T
A
C
N
F
H
2
GL
5
A
0
R
A
G
M
A
E
A
C
R
X I N T
P
U
T F G
N
C
H
A S
G
S
R
IS O U
N
D
AC INPUT
230 V
AC OUTPUT
52
230 V
EN
Page 23
CombiPower Configuring the device with the remote control
Uninterruptible power supply
The device can be used as an uninterruptible power supply. The device powers connected loads from a battery when the mains supply fails
You can use this function, for example, to continue running your air conditioning system if the 230 V power supply fails.
NOTE
During installation, the period during which the inverter remains in
I
operation after a power cut is configured. This prevents the battery from deep discharging.
Example:
INV. AC
OUTPUT
A
M
4
2
12/24 V
X
-
+
230 V
PO
S
[+ ]
I N V
C H R
B N B
D E N
N
B E
NEG
G
N
B
F
A
E
N
I
B
L U
E
A
R
E
T .
T
[-]
O
E
.
M
N
M
P
O
.
C
C : W
IN
IN
V
E
V
R
.
A
TO
R
O
C
S
U R
-2
T
3
P
2L
U T
L
C
F
M
G
5 0
A
A
N
M
C
C
A
A
O
X
N
U
1
O
T P
F
U
F
L
C
T
A
C
N
F
H
2
GL
5
A
0
R
A
G
M
A
E
A
C
R
X
I
N T
P U
T F G
N
C H
A S
G
S
R
IS O U
N
D
AC OUTPUT
0 V
AC INPUT
0 V
EN
53
Page 24
Configuring the device with the remote control CombiPower
Battery charger function
The connected battery is charged and conditioned if a 230 V power source is connected to “AC INPUT”.
Example:
INV. AC
OUTPUT
A
M
4
2
12/24 V
X
+
0 V
-
P OS
[+ ]
I N V
C H R
B N B
D E N
N
B E
NEG
G
N
B
F
A
E
N
I
B
L U
E
A
R
E
T .
T
[-]
O
E
.
M
N
M
P
O
.
C
C : W
IN
IN
V
E
V
R
.
A
TO
R
O
C
S
U R
­2
T
3
P
2
U T
L L C
F
M
G
5 0
A
A
N
M
C
C
A
A
X
O
N
U
1
O
T P
F
U
F
L
C
T
A
C
N
F
H
2
G
5
A
0
R
A
G
M
A
E
A
C
R
X I N T
P
U
T
L
F G
N
C H
A S
G
S
R
I
S O U
N
D
AC INPUT
230 V
AC OUTPUT
0 V
54
EN
Page 25
CombiPower Configuring the device with the remote control
6.3 Configuring functions
Activating functions
Switch on the device (see chapter “Switching the device on and off” on
page 48).
Press the
” button on the remote control for longer than 2 seconds.
You are now in setup mode.
Use the “” or “” button to navigate to the “P.S. Mode Param” menu.
Press the
” button to select the menu.
Use the “” or “” button to navigate to the “Power Sharing” parameter.
Press the
” button to select the parameter.
Use the “” or “” button to set the “SHAR. SUPP. GEN.” value.
Briefly press the
” button to save the value.
Deactivating the generator function
Use the “” or “” button to set the “SHAR. SUPP.” value.
Briefly press the
” button to save the value.
Deactivating the support function
Use the “” or “” button to set the “SHAR.” value.
Briefly press the
” button to save the value.
You can quit setup mode at any time.
Press the
” button on the remote control.
EN
55
Page 26
Configuring the device with the remote control CombiPower
Deactivating the inverter function
Switch on the device (see chapter “Switching the device on and off” on
page 48).
Press the
” button on the remote control for longer than 2 seconds.
You are now in setup mode.
Use the “” or “” button to navigate to the “Change Run Mode” menu.
Press the
” button to select the menu.
Use the “” or “” button to navigate to the “CHR Power On” parameter.
Briefly press the
” button to save the parameter.
6.4 Limiting the input current at the 230 V input (power sharing level)
You can restrict the input current at the 230 V input if the available electricity connection is limited.
This is how to limit the input current at the 230 V input:
Switch on the device (see chapter “Switching the device on and off” on
page 48).
Press the
” button on the remote control for longer than 2 seconds.
You are now in setup mode.
Use the “” or “” button to navigate to the “P.S. Mode Param” menu.
Press the
” button to select the menu.
Use the “” or “” button to navigate to the “Iac setup” parameter.
Press the
” button to select the parameter.
Use the “” or “” button to set the input current.
Briefly press the
” button to save the value.
56
EN
Page 27
CombiPower Maintaining and cleaning the device
7 Maintaining and cleaning the device
NOTICE!
Do not use any sharp or hard objects for cleaning since they may
A
Disconnect the device from the 230 V power supply.
Disconnect the device from the battery.
Prevent the device from being switched on.
Occasionally clean the device with a damp cloth.
Regularly clean the vents.
Check the electrical wiring at least once a year.
Repair any defects such as loose connections or burnt cables.
damage the device.
8 Troubleshooting
Fault Cause Remedy
No output voltage at “INV. AC OUTPUT” and “AC OUT­PUT” and no charging cur­rent; no LED lights up
No output voltage, “Alarm” LED lights up red, display shows “Overload Alert”
No output voltage, “Alarm” LED lights up red, display shows “UV Alert”
The device is switched off Check the main switch The device is defective Replace the device No contact to the battery Check the contact and cables
Switch on the ignition if nec-
essary Battery discharged Charge the battery Battery defective Replace the battery Defective fuse (in the device or
the vehicle) The device is at 100% load Reduce the load (switch off
Battery voltage too low Charge the battery
Replace the fuse with one of
the same rating
consumer units)
Switch off the device and on
again
EN
57
Page 28
Troubleshooting CombiPower
Fault Cause Remedy
No output voltage, “Inverter” LED lights up red, display shows “OLP Shutdown”
No output voltage, “Inverter” LED lights up red, display shows “OLP Shutdown”
No output voltage, “Inverter” LED lights up red, display shows “UVP Shutdown”
No output voltage, “Inverter” LED lights up red, display shows “ENIR TEMP Shut­down”
No output voltage, “Inverter” LED lights up red, display shows “H.S. TEMP Shut­down”
Short circuit Incorrect wiring
Overload Reduce the load (switch off
DC overvoltage Reduce the battery voltage or
DC undervoltage Check the cable
Overheating Check the ventilation grilles
Check the 230 V cable
consumer units)
Switch off the device and on
again
replace the battery
Charge the battery
and clean them if necessary
Improve the ventilation
Set up the device somewhere
cooler
No output voltage, “Inverter” LED lights up red, display shows “BAT. TEMP Shut­down”
No charging current Incorrect frequency Check the configured fre-
quency
No charging current, “Charger” and “AC Grid” LEDs are off
No charging current, “Alarm” LED lights up red, display shows “UV Alert”
The device constantly restarts
No 230 V power Check the 230 V power
supply
Check the wiring Overheating Switch off the consumer
units.
Let the inverter cool down
and ensure better ventilation No connection to the battery Check the battery wiring
NOTE
If you have detailed questions on the battery specifications,
I
please contact the battery manufacturer.
58
EN
Page 29
CombiPower Warranty
9Warranty
The statutory warranty period applies. If the product is defective, please contact the manufacturer's branch in your country (see the back of the instruction manual for the addresses) or your retailer.
For repair and guarantee processing, please include the following docu­ments when you send in the device:
z A copy of the receipt with purchasing date z A reason for the claim or description of the fault
10 Disposal
Place the packaging material in the appropriate recycling waste bins
wherever possible.
M
If you wish to finally dispose of the product, ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations.
EN
59
Page 30
Technical data CombiPower
11 Technical data
General technical data
CombiPower 2012 CombiPower 2024
Item no. 9102600104 9102600105
Heat dissipation Housing/fan
Ambient temperature at full load –25 °C – +40 °C
Ambient temperature for storage –30 °C – +70 °C
Power derating 50 W/°C, 41 °C – 60 °C
Air humidity 0 – 93%, non-condensing
Bypass relay 25 A, 250 Vw
Earth relay Supplied for earthing the neutral conduc-
tor in inverter mode, deactivated by
default
Power sharing function Inverter mode, charging mode, power
sharing (power sharing, generator
function (mains voltage function),
power support)
Weight 16.5 kg
Testing/certification EN60950-1
According to 2009/19/EC (2004/104/EC) directive, EMC directive for motor vehi­cles
EN55022: 1998 + A1: 2000 + A2: 2003 Class A
EN55024: 1997 + A1: 2001 + A2: 2003 EN61000-3-2: 2006 Class A EN61000-3-3: 1995 + A1: 2001
60
EN
Page 31
CombiPower Technical data
Input data
CombiPower 2012 CombiPower 2024
Rated input voltage 12 V g 24 V g
Input voltage range 10.5 – 16 Vg 21 – 32 Vg
Input overvoltage protection 15 – 16 Vg 30 – 32 Vg
Input undervoltage protection (programmable)
Idle current consumption 5 A 2.5 A
Standby current consumption 1.5 A 0.75 A
10.5 – 11.5 Vg 21 – 23 Vg
Output data
CombiPower 2012 CombiPower 2024
Output voltage (programmable) 200 – 240 Vw ±5%
Constant output power 2000 VA
Frequency (programmable) 47 – 63 Hz ±0.01%
Peak output power 2300 VA for up to 3 min
3000 VA pulse power
Efficiency > 87% at 12 Vg > 88% at 24 Vg
Short circuit protection Yes, Ipk
Wave form Pure sine wave,
Protective devices
DC battery connection Input fuse
AC inverter output Power-regulated inverter
AC output None
AC input 30 A fuse to battery charger
Battery protection Temperature sensor on battery
EN
maximum 3% distortion
CombiPower 2012 CombiPower 2024
30 A fuse to for AC input
61
Page 32
Technical data CombiPower
AC INPUT technical data
CombiPower 2012 CombiPower 2024
Rated input voltage 230 Vw
Frequency 50 Hz
Input voltage range 180 – 260 Vw
Frequency range 47 – 63 Hz
Rated current 7.4 A (at 230 V)
Power factor correction > 98% (40% load)
Technical data for charging
CombiPower 2012 CombiPower 2024
Charging current 0 – 100 A 0 – 50 A
Charging current of second battery connection
I phase (bulk) charging voltage
1)
U0 phase (absorption) charging voltage
1)
U phase (floating) charging voltage
1)
5 A, 3-step charger 2.5 A, 3-step
charger
14.4 V 28.8 V
14.4 V 28.8 V
13.5 V 27 V
Battery temperature compensation –25 mV/°C –50 mV/°C
1)
Values apply for the setting “Battery type = Standard” (Menu “Charge Parameter”)
62
EN
Page 33
CombiPower Technical data
Messages
CombiPower 2012 CombiPower 2024
Remote control Two-line display
Keypad
LEDs: red, green, orange
Remote control Controls ON/OFF mode
Floating contact With relay
Fan mode Faults reported with alarm signal
Speed-regulated according to load and
temperature
Connection current values
CombiPower 2012 CombiPower 2024
INV. AC OUTPUT Max. 25 A
AC OUTPUT Max. 50 A
AC INPUT Max. 50 A
Different versions, technical modifications and delivery options reserved.
EN
63
Page 34
k Dometic WAECO International GmbH
Hollefeldstraße 63 · D-48282 Emsdetten +49 (0) 2572 879-195 · +49 (0) 2572 879-322 Mail: info@dometic-waeco.de · Internet: www.dometic-waeco.de
Europe
a Dometic Austria GmbH
Neudorferstrasse 108 2353 Guntramsdorf
+43 2236 908070+43 2236 90807060
Mail: info@waeco.at
h Dometic Switzerland AG
Riedackerstrasse 7a CH-8153 Rümlang (Zürich)
+41 44 8187171+41 44 8187191
Mail: info@dometic-waeco.ch
l Dometic Denmark A/S
Nordensvej 15, Taulov DK-7000 Fredericia
+45 75585966+45 75586307
Mail: info@waeco.dk
m Dometic Spain S.L.
Avda. Sierra del Guadarrama, 16 E-28691 Villanueva de la Cañada Madrid
+34 902 111 042+34 900 100 245
Mail: info@dometic.es
p Dometic S.N.C.
ZA du Pré de la Dame Jeanne F-60128 Plailly
+33 3 44633500+33 3 44633518
Mail: info@dometic.fr
q Dometic Finland OY
Mestarintie 4 FIN-01730 Vantaa
+358 20 7413220+358 9 7593700
Mail: info@dometic.fi
C Dometic Italy S.p.A.
Via Virgilio, 3 I-47100 Forlì
+39 0543 754901+39 0543 756631
Mail: info@dometic.it
L Dometic Norway AS
Skolmar 24 N-3232 Sandefjord
+47 33428450+47 33428459
Mail: firmapost@waeco.no
N Dometic Benelux B.V.
Ecustraat 3 NL-4879 NP Etten-Leur
+31 76 5029000+31 76 5029090
Mail: info@dometic.nl
U Dometic Scandinavia AB
Gustaf Melins gata 7 S-42131 Västra Frölunda (Göteborg)
+46 31 7341100+46 31 7341101
Mail: info@waeco.se
4 Dometic UK Ltd.
Dometic House · The Brewery Blandford St. Mary Dorset DT11 9LS
+44 844 626 0133+44 844 626 0143
Mail: sales@dometic.co.uk
Overseas + Middle East
8 Dometic Australia
1 John Duncan Court Varsity Lakes QLD 4227
+61 7 55076000+61 7 55076001
Mail: sales@dometic-waeco.com.au
5 WAECO Impex Ltd.
Suites 2207-2211 · 22/F · Tower 1 The Gateway · 25 Canton Road, Tsim Sha Tsui · Kowloon Hong Kong
+852 24611386+852 24665553
Mail: info@dometic-waeco.com.hk
7 WAECO Impex Ltd.
Taipei Office 2 FL-3 · No. 56 Tunhua South Rd, Sec 2 Taipei 106, Taiwan
+886 2 27014090+886 2 27060119
Mail: marketing@dometic-waeco.com.tw
6 Dometic AB
Regional Office Middle East P O Box 74775 Dubai, United Arab Emirates
+971 4 321 2160+971 4 321 2170
Mail: info@dometic.ae
0 Dometic Marine Division
2000 N. Andrews Ave. Extension Pompano Beach, FL 33069 USA
+1 954 973 2477+1 954 979 4414
Mail: marinesales@dometicusa.com
3.03.20.1834 DE-IT 10/2011
www.dometic-waeco.com
Loading...