Waeco CFX35, CFX40, CFX50, CFX65, CFX65DZ Instruction Manual

Page 1
CFX35, CFX40, CFX50, CFX65, CFX65DZ
Compressor Cooler
Instruction Manual
Page 2
Page 3
AU
3
Please read this operating manual carefully before starting the device. Keep it in a safe place for future reference. If the device is passed on to another person, this operating manual must be handed over to the user along with it.
The manufacturer cannot be held liable for damage resulting from
improper usage or incorrect operation.
Contents
1 Explanation of symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2 Safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1 General safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.1 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4 Intended use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5 Function description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5.1 Scope of functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5.2 Operating and display elements . . . . . . . . . . . . . . . . . . . . . . 9
6Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6.1 Before initial use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6.2 Energy saving tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.3 Connecting the cooler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.4 Using the battery monitor . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6.5 Using the cooler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
6.6 Setting the temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6.7 Using the emergency switch (where fitted) . . . . . . . . . . . . . 16
6.8 USB port for power supply . . . . . . . . . . . . . . . . . . . . . . . . . 16
6.9 Switching off the cooler . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6.10 Defrosting the cooler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
6.11 Replacing the device fuse . . . . . . . . . . . . . . . . . . . . . . . . . . 17
6.12 Replacing the plug fuse (12/24 V) . . . . . . . . . . . . . . . . . . . 18
6.13 Replacing the light PCB . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7 Cleaning and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
8Guarantee. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
9 Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
10 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
11 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
2.2 Operating the device safely . . . . . . . . . . . . . . . . . . . . . . . . 6
Page 4
AU
Explanation of symbols CFX35 – CFX65DZ
4
1 Explanation of symbols
D
DANGER! Safety instruction: Failure to observe this instruction will cause
fatal or serious injury.
!
WARNING! Safety instruction: Failure to observe this instruction can cause
fatal or serious injury.
!
CAUTION! Safety instruction: Failure to observe this instruction can lead to
injury.
A
NOTICE!
Failure to observe this instruction can cause material damage and impair the function of the product.
I
NOTE
Supplementary information for operating the product.
Action: This symbol indicates that action is required on your
part. The required action is described step-by-step.
This symbol describes the result of an action. fig. 1 5, page 3: This refers to an element in an illustration. In this
case, item 5 in figure 1 on page 3.
2 Safety instructions
2.1 General safety
D
DANGER!
On boats: If the appliance is powered by the mains, ensure that
the power supply has a residual current circuit breaker.
Page 5
AU
CFX35 – CFX65DZ Safety instructions
5
!
WARNING!
Do not operate the device if it is visibly damaged.
This device may only be repaired by qualified personnel.
Improper repairs can lead to considerable hazards.
Persons (including children) whose physical, sensory or mental
capacities or whose lack of experience or knowledge prevent them from using this product safely should not operate it without the supervision or instruction of a responsible person.
Electrical devices are not toys.
Always keep and use the device out of the reach of children.
Children must be supervised to ensure that they do not play with
the device.
If this device's power cable is damaged, it must be replaced by
the manufacturer, customer service or a similarly qualified person in order to prevent safety hazards.
Do not store any explosive substances such as spray cans with
propellants in the device.
!
CAUTION!
Disconnect the device from the mains
before cleaning and maintenance –after use
Food may only be stored in its original packaging or in suitable
containers.
A
NOTICE!
Only connect the device as follows:
With the DC cable to a DC plug socket in the vehicle (e. g.
cigarette lighter)
Or with the 230 V connection cable to the 230 V AC mains
supply
Check that the voltage specification on the type plate
corresponds to that of the energy supply.
The cooling device is not suitable for transporting caustic
materials or materials containing solvents.
Never pull the plug out of the socket by the cable.
If the cooler is connected to the DC socket: Disconnect the
cooler and other power consuming devices from the battery before connecting the quick charging device.
Page 6
AU
Safety instructions CFX35 – CFX65DZ
6
If the cooler is connected to the DC socket: Disconnect the
cooler or switch it off when you turn off the engine. Otherwise you may discharge the battery.
2.2 Operating the device safely
D
DANGER!
Do not touch exposed cables with your bare hands. This
especially applies when operating the device with an AC mains power supply.
!
CAUTION!
Before starting the device, ensure that the power supply line
and the plug are dry.
A
NOTICE!
Do not use electrical devices inside the cooler unless they are
recommended by the manufacturer for the purpose.
Do not place the device near naked flames or other heat
sources (heaters, direct sunlight, gas ovens etc.).
Danger of overheating!
Ensure at all times that there is sufficient ventilation so that the heat that arises during operation does not build up. Make sure that the device is sufficiently far away from walls and other objects so that the air can circulate.
Ensure that the ventilation slots are not covered.
Do not fill the inner container with ice or fluid.
Never immerse the device in water.
Protect the device and the cable against heat and moisture.
Page 7
AU
CFX35 – CFX65DZ Scope of delivery
7
3 Scope of delivery
3.1 Accessories
Available as accessory (not included in scope of delivery):
Item Quantity Description
11Cooler
2 1 Connection cable for 12/24 Vg connection
3 1 Connection cable for 100 – 240 V~ connection
1 Operating manual
Designation Item no. Model
Universal fixing kit (belt system) 4445100725 CFX-UFK
Wireless display 4445100726 CFX-WD
SET
+
°
1
2
3
1
Page 8
AU
Intended use CFX35 – CFX65DZ
8
4 Intended use
The cooler is suitable for cooling and freezing foods. The device is also suitable for use on boats.
The device is designed to be operated from a 12 V
g or 24 Vg on-
board supply socket of a vehicle (e. g. cigarette lighter), boat or caravan as well as from a 100–240 V AC mains.
!
CAUTION! Health hazard!
Please check if the cooling capacity of the device is suitable for storing the food or medicine you wish to cool.
5 Function description
The cooler can chill products, keep them cool as well as freeze them. A low maintenance refrigerant circuit with compressor pro­vides the cooling. The generous insulation and powerful compres­sor ensure efficient and fast cooling.
The cooler is portable.
The cooler can withstand a constant heel (inclination) of 30°, for ex­ample when used on boats.
5.1 Scope of functions
Power supply with priority circuit for connecting to the AC mainsThree-level battery monitor to protect the vehicle batteryDisplay with temperature gauge in °C and °F
switches off automatically at low battery voltage
Temperature setting: With two buttons in steps of 1 °C (2 °F)Foldable carrying handlesUSB port for power supplyEmergency switch (where fitted)Removable wire basket
Page 9
AU
CFX35 – CFX65DZ Function description
9
5.2 Operating and display elements
Latch for lid, fig. 2 1
Operating panel, fig. 3
Item Description Explanation
1ON
OFF
Switches the cooler on or off when the button is pressed for between one and two seconds
2POWER
P Status indication
LED lights up green: Compressor is on
LED lights up orange: Compressor is off
LED flashes orange: display switched off
automatically due to low battery voltage
3 ERROR LED flashes red: Device is switched on
but not ready for opera­tion
1
SET
+
°
1
2
CFX35, CFX40 CFX50, CFX65, CFX65DZ
SET
+
°
1 3 4 5 6 72
3
Page 10
AU
Function description CFX 35 – CFX65DZ
10
Connection sockets, fig. 4
Emergency switch (when fitted) and USB port, fig. 5
4 SET Selects the input mode
– Temperature setting – Celsius or Fahrenheit display – Set battery monitor
5 Display, shows the information
6 DOWN – Press once to decrease the value
7 UP + Press once to increase the value
Item Description
1 Connection socket AC voltage supply
2 Fuse holder
3 Connection socket DC voltage supply
Item Description
1 Emergency switch
2 USB port for power supply
Item Description Explanation
100-240V~AC
12/24V DC
1
2 3
4
EMERGENCY
OVERRIDE
NORMAL
USE
1 2
5
Page 11
AU
CFX35 – CFX65DZ Operation
11
6 Operation
6.1 Before initial use
I
NOTE
Before starting your new cooler for the first time, you should clean it inside and outside with a damp cloth for hygienic reasons (please also refer to the “Cleaning and maintenance” on page 19).
Reversing the lid opening direction
CFX50, CFX65, CFX65DZ
The lid hinges can be moved to the opposite side if you want to open the lid from the opposite direction. To do this, proceed as follows:
Open the lid and remove it (fig. 6 A).Remove 3 screws per hinge (fig. 6 B) and take off hinges.
Remove plastic covers from new hinge positions with a small
screwdriver and re-fit to old hinge positions.
Re-fit hinges in new positions.Insert the lid in the hinges on the opposite side (fig. 6 C).
SET
+
°
SET
+
°
6
CFX50, CFX65, CFX65DZ
A
B
C
Page 12
AU
Operation CFX35 – CFX65DZ
12
Selecting the temperature units
Temperature display units can be switched between Celsius and Fahrenheit as follows:
Switch on the cooler.Press the “SET” button (fig. 3 4, page 9) twice.Use the “UP +” (fig. 3 7, page 9) or “DOWN -” (fig. 3 6,
page 9) buttons to select Celsius or Fahrenheit.
The selected temperature units then appear in the display for a
few seconds. The display flashes several times before it returns to the current temperature.
6.2 Energy saving tips
Choose a well ventilated installation location which is protected
against direct sunlight.
Allow warm food to cool down first before placing it in the device
to keep cool.
Do not open the cooling device more often than necessary.Do not leave the cooler unit open for longer than necessary.Defrost the cooler once a layer of ice forms.Avoid unnecessary low temperatures.
6.3 Connecting the cooler
Connecting to a battery (Vehicle or boat)
The cooler can be operated with 12 V or 24 V
g.
A
NOTICE! Danger of damage!
Disconnect the cooler and other consumer units from the battery before you connect the battery to a quick charging device. Overvoltage can damage the electronics of the device.
For safety reasons the cooler is equipped with an electronic system to prevent the polarity reversal. This protects the cooler against short-circuiting when connecting to a battery.
Plug the 12/24-V connection cable (fig. 1 2, page 7) into the
device DC voltage socket and also into a 12 V or 24 V cigarette lighter socket.
Page 13
AU
CFX35 – CFX65DZ Operation
13
Connecting to a 100–240 V AC mains (E.g. in the home or office)
D
DANGER! Danger of electrocution!
Never handle plugs and switches with wet hands or if you are
standing on a wet surface.
If you are operating your cooler on board a boat from a mains
connection of 100–240 V
~
, you must install a residual current circuit breaker between the 100–240 V AC mains and the cooler. Seek advice from a trained technician.
The coolers have an integrated multi-voltage power supply with priority circuit for connecting to an AC voltage source of 100–240 V. The priority circuit automatically switches the cooler to mains oper­ation, if the device is connected to a 100–240 V AC mains, even if the 12/24 V connection cable is still attached.
Plug the 100–240 V connection cable (fig. 1 3, page 7) into
the device AC voltage socket and connect it to the 100–240 V AC voltage mains.
6.4 Using the battery monitor
The device is equipped with a multi-level battery monitor that protects your vehicle battery against excessive discharging when the device is connected to the on-board 12/24 V supply.
If the cooler is operated when the vehicle ignition is switched off, the cooler switches off automatically as soon as the supply voltage falls below a set level. The cooler will switch back on once the battery has been recharged to the restart voltage level.
A
NOTICE! Danger of damage!
When switched off by the battery monitor, the battery will no longer be fully charged. Avoid starting repeatedly or operating current consumers without longer charging phases. Ensure that the battery is recharged.
Page 14
AU
Operation CFX35 – CFX65DZ
14
In “HIGH” mode, the battery monitor responds faster than at the levels “LOW” and “MED” (see the following table).
The battery monitor mode can be selected as follows:
Switch on the cooler.Press the “SET” button (fig. 3 4, page 9) three times.Use the “UP +” (fig. 3 7, page 9) or “DOWN -” (fig. 3 6,
page 9) buttons to select the battery monitor mode.
Digital display will be as follows:
Lo (LOW), Πd (MED), Hi (HIGH)
The selected mode then appears in the display for a few sec-
onds. The display flashes several times before it returns to the current temperature.
I
NOTE
When the cooler is supplied by the starter battery, select the battery monitor mode “HIGH”. If the cooler is connected to a supply battery, the battery monitor mode “LOW” will suffice.
6.5 Using the cooler
A
NOTICE! Danger of overheating!
Ensure at all times that there is sufficient ventilation so that the heat that generated during operation can dissipate. Ensure that the ventilation slots are not covered. Make sure that the device is sufficiently far away from walls and other objects so that the air can circulate.
Place the cooler on a firm foundation.
Make sure that the ventilation slots are not covered and that the heated air can dissipate.
Battery monitor mode LOW MED HIGH
Switch-off voltage at 12 V 10.1 V 11.4 V 11.8 V
Restartvoltage at 12 V 11.1 V 12.2 V 12.6 V
Switch-off voltage at 24 V 21.5 V 24.1 V 24.6 V
Restart voltage at 24 V 23.0 V 25.3 V 26.2 V
Page 15
AU
CFX35 – CFX65DZ Operation
15
I
NOTE
Place the cooler as shown (fig. 1, page 7).If you operate the box in a different position it can be damaged.
Close the cooler, see “Connecting the cooler” on page 12.
A
NOTICE! Danger from excessively low temperature!
Ensure that the only those objects are placed in the cooler that are intended to be cooled at the selected temperature.
Press the “ON/OFF” button (fig. 3 1, page 9) for between one
and two seconds.
The LED “P“ lights up (fig. 3 2, page 9).The display (fig. 3 5, page 9) switches on and shows the
current cooling temperature.
I
NOTE Displayed temperature
CFX 35, CFX 40, CFX 50, CFX 65:
The temperature displayed is that of the middle of the large interior compartment.
CFX 65DZ:
With fridge/freezer divider in: The temperature displayed is
that of the middle of the freezer compartment.
With fridge/freezer divider out: The actual compartment tem-
perature will be considerably warmer than the displayed temperature.
All models:
Temperatures elsewhere in the compartment (away from centre) will deviate from displayed temperature.
The cooler starts cooling the interior.
I
NOTE
When operating with the battery, the display switches off auto­matically if the battery voltage is low. The LED “P“ flashes orange.
Latching the cooler lid
Close the lid.Press the latch (fig. 2 1, page 9) down, until it latches in
place audibly.
Page 16
AU
Operation CFX35 – CFX65DZ
16
6.6 Setting the temperature
Press the “SET” button (fig. 3 4, page 9) once.Use the “UP +” (fig. 3 7, page 9) and “DOWN -” (fig. 3 6,
page 9) buttons to select the cooling temperature.
The cooling temperature appears in the display for a few
seconds. The display flashes several times and then the current temperature is displayed again.
6.7 Using the emergency switch (where fitted)
The emergency switch (fig. 5 1, page 10) is located below the control panel. For normal operation the switch is in the “NORMAL USE“ position.
If an electronic control failure occurs, slide the switch to
“EMERGENCY OVERRIDE“ position
I
NOTE
If the switch is in the “EMERGENCY OVERRIDE“ position, the cooler freezes with full cooling capacity.
6.8 USB port for power supply
USB port allows you to charge small devices like mobile phones and mp3-players.
To use your cooling box with any USB devices, simply connect a USB cable (not included) to your device.
I
NOTE
Ensure that any small device connected to the USB port is compatible with 5 V/500 mA operation.
6.9 Switching off the cooler
Empty the cooler.
Switch the cooler off.
Pull out the connection cable.
If you do not want to use the cooler for a longer period of time:
Leave the cover slightly open. This prevents odour build-up.
Page 17
AU
CFX35 – CFX65DZ Operation
17
6.10 Defrosting the cooler
Humidity can form frost in the interior of the cooling device or on the evaporator. This reduces the cooling capacity. Defrost the device in good time to avoid this.
A
NOTICE! Danger of damage!
Never use hard or pointed tools to remove ice or to loosen objects which have frozen in place.
To defrost the cooler, proceed as follows:
Take out the contents of the cooling device.
If necessary, place them in another cooling device to keep them
cool.
Switch off the device.
Leave the lid open.
Wipe off the defrosted water.
6.11 Replacing the device fuse
D
DANGER! Danger of electrocution!
Disconnect the connection cable before you replace the device fuse.
Pull off the connection cable.Pry out the fuse insert (fig. 4 2, page 10) with a screwdriver.
Replace the defective fuse with a new one that has the same
rating (T4AL 250V).
Press the fuse insert back into the housing.
Page 18
AU
Operation CFX35 – CFX65DZ
18
6.12 Replacing the plug fuse (12/24 V)
Turn anticlockwise the cap (fig. 7 1) to move it and pin
(fig. 7 2) from the plug.
Press one end of the fuse (fig. 7 3) and take it out.
Replace the defective fuse with a new one that has the same
rating (10 A).
Re-assemble the plug in the reverse order.
6.13 Replacing the light PCB
Pry out the transparent cover with a screwdriver (fig. 8 1).Unscrew the PCB mounting screws (fig. 8 2).Pull out the plug from the PCB (fig. 8 3).
Replace the defective light PCB with a new one.
Fit new PCB using reverse of removal instructions.
Press the transparent cover back into the housing.
1
2
3
7
1.
2.
3.
SET
+
°
8
Page 19
AU
CFX35 – CFX65DZ Cleaning and maintenance
19
7 Cleaning and maintenance
!
WARNING!
Always disconnect the device from the mains before you clean and service it.
A
NOTICE! Risk of damage
Never clean the cooler under running water or in dish water.
Do not use abrasive cleaning agents or hard objects during
cleaning as these can damage the cooler.
Occasionally clean the device interior and exterior with a damp
cloth.
8 Guarantee
The statutory warranty period applies. If the product is defective, please contact the manufacturer's branch in your country (see the back of the instruction manual for the addresses) or your retailer.
For repair and guarantee processing, please include the following documents when you send in the device:
A copy of the receipt with purchasing dateA reason for the claim or description of the fault
Page 20
AU
Troubleshooting CFX35 – CFX65DZ
20
9 Troubleshooting
Fault Possible cause Suggested remedy
Device does not func­tion, LED does not glow.
There is no voltage pre­sent in the 12/24 V socket (cigarette lighter) in your vehicle.
The ignition must be switched on in most vehicles to apply current to the cigarette lighter.
No voltage present in the AC voltage socket.
Try using another plug socket.
The device fuse is defec­tive.
Replace the device fuse, see “Replacing the device fuse” on page 17.
The integrated mains adapter is defective.
This can only be repaired by an authorised repair centre.
The device does not cool (plug is inserted, “POWER” LED is lit).
Defective compressor. This can only be repaired by an
authorised customer services unit.
The device does not cool (plug is inserted, “POWER” LED flashes orange, display is switched off).
Battery voltage is too low.
Test the battery and charge it as needed.
When operating from the 12/24-V socket (cigarette lighter):
The ignition is on and the device is not working and the LED is not lit.
Pull the plug out of the socket and make the following checks.
The cigarette lighter socket is dirty. This results in a poor electri­cal contact.
If the plug of your cooler becomes very warm in the cigarette lighter socket, either the lighter socket must be cleaned or the plug has not been assembled correctly.
The fuse of the 12/24 V plug has blown.
Replace the fuse (10 A) in the 12/24 V plug, see “Replacing the plug fuse (12/24 V)” on page 18.
The vehicle fuse has blown.
Replace the vehicle’s 12/24 V socket fuse (usually 15 A). Please refer to your vehi­cle’s operating manual.
The display shows an error message (e.g. “Err1”) and the appli­ance does not cool.
The appliance has switched off due to an internal fault.
This can only be repaired by an authorised repair centre.
Page 21
AU
CFX35 – CFX65DZ Disposal
21
10 Disposal
Place the packaging material in the appropriate recycling waste
bins wherever possible.
M
If you wish to finally dispose of the product, ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations.
11 Technical data
CFX35 CFX40
Item no. 9105303570 9105303571
Connection voltage:
12/24 V
g and 100–240 V
~
Rated current:
12 V
g: 7,0 A
24 Vg: 3,2 A
100 V
w
: 0,86 A
240 V
w
: 0,42 A
Cooling capacity: +10 °C to –22 °C (+50 °F to –8 °F)
Category: 1
Energy efficiency class: A++
Energy consumption: 62 kWh/annum 64 kWh/annum
Gross volume: 34,5 l 41 l
Storage volume: 32 l 38 l
Climate class: N, T
Ambient temperature: +16°C –
+43 °C
Noise emission: 45 dB(A) USB 5 Vg, 500 mA
Dimensions (W x H x D) in mm: 630 x 411 x 398 630 x 461 x 398
Weight: 21 kg 22 kg
Page 22
AU
Technical data CFX35 – CFX65DZ
22
I
NOTE
If the ambient temperature is above +32°C (+90 °F), the minimum temperature cannot be attained.
Test/certificates:
The coolant circuit contains R-134a.
CFX50 CFX65 CFX65DZ
Item no. 9105303572 9105303573 9105303574
Connection volt­age:
12/24 V
g and 100–240 V
~
Rated current:
12 V
g: 7,8 A
24 Vg: 3,6 A
100 V
w
: 0,95 A
240 V
w
: 0,46 A
12 V
g: 8,2 A
24 Vg: 3,8 A
100 V
w
: 1,0 A
240 V
w
: 0,48 A
12 V
g: 5,5 A
24 Vg: 2,6 A
100 V
w
: 0,75 A
240 V
w
: 0,37 A
Cooling capacity: +10 °C to –22 °C (+50 °F to –8 °F)
Category: 1
Energy efficiency class:
A++ A+
Energy consumption:
66 kWh/annum 69 kWh/annum 115 kWh/annum
Gross volume: 50 l 65 l with divider: 61 l
without divider: 65 l
Storage volume: 46 l 60 l 53 l
Climate class: N, T
Ambient temperature:
+16°C –
+43 °C
Noise emission: 45 dB(A) USB 5 Vg, 500 mA
Dimensions (W x H x D) in mm:
661 x 471x 455 661 x 561 x 455 661 x 561 x 455
Weight: 24,6 kg 27 kg 27,5 kg
Page 23
Page 24
AUSTRALIA Dometic Australia Pty. Ltd.
1 John Duncan Court Varsity Lakes QLD 4227
+61 7 55076000+61 7 55076001
Mail: sales@dometic-waeco.com.au
AUSTRIA Dometic Austria GmbH
Neudorferstrasse 108 2353 Guntramsdorf
+43 2236 908070+43 2236 90807060
Mail: info@waeco.at
BENELUX Dometic Benelux B.V.
Ecustraat 3 NL-4879 NP Etten-Leur
+31 76 5029000+31 76 5029090
Mail: info@dometic.nl
DENMARK Dometic Denmark A/S
Nordensvej 15, Taulov DK-7000 Fredericia
+45 75585966+45 75586307
Mail: info@waeco.dk
FINLAND Dometic Finland OY
Mestarintie 4 FIN-01730 Vantaa
+358 20 7413220+358 9 7593700
Mail: info@dometic.fi
FRANCE Dometic S.N.C.
ZA du Pré de la Dame Jeanne F-60128 Plailly
+33 3 44633500+33 3 44633518
Mail: info@dometic.fr
HONG KONG WAECO Impex Ltd.
Suites 2207-2211 · 22/F · Tower 1 The Gateway · 25 Canton Road, Tsim Sha Tsui · Kowloon Hong Kong
+852 24611386+852 24665553
Mail: info@dometic-waeco.com.hk
ITALY Dometic Italy S.r.l.
Via Virgilio, 3 I-47100 Forlì
+39 0543 754901+39 0543 756631
Mail: info@dometic.it
NORWAY Dometic Norway AS
Skolmar 24 N-3232 Sandefjord
+47 33428450+47 33428459
Mail: firmapost@waeco.no
POLAND Dometic Poland Sp. z o.o.
Ul. Puławska 435A 02-801 Warszawa Poland
+48 22 414 32 00+48 22 414 32 01
Mail: info@dometic.pl
RUSSIA Dometic RUS LLC
Komsomolskaya square 6-1 107140 Moscow Russia
+7 495 780 79 39+7 495 916 56 53
Mail: info@dometic.ru
SLOVAKIA Dometic Slovakia s.r.o.
Tehelná 8 SK-98601 Fiľakovo
+421 47 4319 107+421 47 4319 166
Mail: info@dometic.sk
SPAIN Dometic Spain S.L.
Avda. Sierra del Guadarrama, 16 E-28691 Villanueva de la Cañada Madrid
+34 902 111 042+34 900 100 245
Mail: info@dometic.es
SWEDEN Dometic Scandinavia AB
Gustaf Melins gata 7 S-42131 Västra Frölunda (Göteborg)
+46 31 7341100+46 31 7341101
Mail: info@waeco.se
SWITZERLAND Dometic Switzerland AG
Riedackerstrasse 7a CH-8153 Rümlang (Zürich)
+41 44 8187171+41 44 8187191
Mail: info@dometic-waeco.ch
TAIWAN WAECO Impex Ltd.
Taipei Office 2 FL-3 · No. 56 Tunhua South Rd, Sec 2 Taipei 106, Taiwan
+886 2 27014090+886 2 27060119
Mail: marketing@dometic-waeco.com.tw
UNITED KINGDOM Dometic UK Ltd.
Dometic House · The Brewery Blandford St. Mary Dorset DT11 9LS
+44 844 626 0133+44 844 626 0143
Mail: sales@dometic.co.uk
UNITED ARAB STATES Dometic AB
Regional Office Middle East P O Box 74775 Dubai, United Arab Emirates
+971 4 321 2160+971 4 321 2170
Mail: info@dometic.ae
UNITED STATES OF AMERICA Dometic Marine Division
2000 N. Andrews Ave. Extension Pompano Beach, FL 33069 USA
+1 954 973 2477+1 954 979 4414
Mail: marinesales@dometicusa.com
GERMANY Dometic WAECO International GmbH
Hollefeldstraße 63 · D-48282 Emsdetten +49 (0) 2572 879-195 · +49 (0) 2572 879-322 Mail: info@dometic-waeco.de · Internet: www.dometic-waeco.de
www.dometic-waeco.com
4445100731_AU 07/2012