This manual provides information and procedures to safely operate
and maintain this Wacker model. For your own safety and protection
from injury, carefully read, understand and observe the safety
instructions described in this manual.
Keep this manual or a copy of it with the machine. If you lose this
manual or need an additional copy, please contact Wacker
Corporation. This machine is built with user safety in mind; however,
it can present hazards if improperly operated and serviced. Follow
operating instructions carefully! If you have questions about operating
or servicing this equipment, please contact Wacker Corporation.
The information contained in this manual was based on machines in
production at the time of publication. Wacker Corporation reserves the
right to change any portion of this information without notice.
All rights, especially copying and distribution rights, are reserved.
Copyright 2007 by Wacker Corporation.
No part of this publication may be reproduced in any form or by any
means, electronic or mechanical, including photocopying, without
express written permission from Wacker Corporation.
Any type of reproduction or distribution not authorized by Wacker
Corporation represents an infringement of valid copyrights and will be
prosecuted. We expressly reserve the right to make technical
modifications, even without due notice, which aim at improving our
machines or their safety standards.
4
PS 2 500 / PS 2 750 / PSA 2 500Safety Information
2.Safety Information
This manual contains DANGER, WARNING, CAUTION, NOTICE and
NOTE callouts which must be followed to reduce the possibility of
personal injury, damage to the equipment, or improper service.
This is the safety alert symbol. It is used to alert you to potential
personal injury hazards. Obey all safety messages that follow this
symbol to avoid possible injury or death.
DANGER indicates a hazardous situation which, if not avoided, will
result in death or serious injury.
DANGER
WARNING
CAUTION
WARNING indicates a hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury.
NOTICE: Used without the safety alert symbol, NOTICE indicates a
hazardous situation which, if not avoided, could result in property
damage.
Note:Contains additional information important to a procedure.
wc_si000040gb.fm5
Safety InformationPS 2 500 / PS 2 750 / PSA 2 500
2.1Operating and Electrical Safety
To reduce risk of electric shock, connect only to a properly grounded,
WARNING
grounding-type receptacle.
Risk of electric shock - This pump has not been investigated for use in
swimming pool areas.
An acceptable motor-control switch shall be provided at the time of
installation according to local codes and regulations.
To reduce risk of electric shock, see instruction manual for proper
installation.
CAUTION: This pump may automatically restart. Prior to working on
the pump or control panel all supply circuits must be disconnected.
CAUTION: Risk of shock - Do not remove cord and strain relief.
2.2Information Labels
LabelMeaning
MADE IN TAIWAN
wc_si000040gb.fm6
A nameplate listing the model number, item number, revision number, and serial number is
attached to each unit. Please record the information found on this plate so it will be available
should the nameplate become lost or damaged.
When ordering parts or requesting service information, you will always be asked to specify the
model number, item number, revision number,
and serial number of the unit.
* The weight (mass) given above is the operating weight of the pump itself, not including the cable
assembly.
Kg (lbs.)
9.5 (21)10.0 (22)16.0 (35)
wc_td000040gb.fm8
PS 2 500 / PS 2 750 / PSA 2 500Technical Data
3.3Dimensions
mm (in.)
185
(7.3)
185
(7.3)
185
(7.3)
185
(7.3)
200
(11)
185
(7.3)
229
(9)
PS 2 500
305
(12)
200
(11)
229
(9)
222
(8.8)
PSA 2 500
305
(12)
PS 2 750
414
(16.3)
wc_td000040gb.fm9
OperationPS 2 500 / PS 2 750 / PSA 2 500
4.Operation
4.1Names of Parts
See Graphic: wc_gr001185
1
2
3
4
5
6
7
8
9
10
11
12
13
14
wc_gr001185
Ref.DescriptionRef.Description
1.Lifting Handle8.Seal-mechanical
2.Coupling9.Lubricant
3.Oil Lifter10.Seal-dust
4.Oil Plug11.Sleeve
5.Cover-suction12.Housing-oil
6.Strainer13.Wear Ring
7.Cable Assembly14.Impeller
wc_tx000121gb.fm10
PS 2 500 / PS 2 750 / PSA 2 500Operation
4.2Prior to operation
When the pump is delivered, first perform the following checks:
•Inspection
While unpacking, inspect the product for damage during shipment, and
make sure all bolts and nuts are tightened properly.
•Specification check
Check the model number to make sure it is the product that was
ordered. Be certain it is the correct voltage and frequency.
Note: If there is any problem with the product as shipped, contact your
nearest dealer or Wacker representative at once.
•Product specifications
Do not operate this product under any conditions other than those for
which it is specified. Failure to observe this precaution can lead to
CAUTION
electrical shock, current leakage, fire, water leakage or other
problems.
4.3Installation
If the pump is used for outdoor fountains, garden ponds and similar
places, or to drain a swimming pool, the pump must be supplied by an
isolating transformer or connected to a Residual Current Device (RCD)
WARNING
with a residual operating current not exceeding 30 mA.
The pump must not be used when people are in the water.
Leakage of pump lubricants may cause pollution of water.
Proper plug must be provided according to local codes and standards.
Refer to wiring diagram.
DO NOT use this pump in liquids other than water, such as oil, salt
water, or organic solvents.
Use with a power supply voltage within ±5% of the rated voltage.
DO NOT use in water temperatures outside the range of 0–40°C (32–
104°F) which can lead to failure, electrical leakage or shock.
DO NOT use in the vicinity of explosive or flammable materials.
Use only in fully assembled state.
Note: Consult your local dealer or Wacker representative before using
with any liquids other than those indicated in this document.
wc_tx000121gb.fm11
OperationPS 2 500 / PS 2 750 / PSA 2 500
Preparing for Installation
Before installing the pump at a work site, you will need to have the
following tools and instruments ready:
•Insulation resistance tester (megohmmeter)
•AC voltmeter
•AC ammeter (clamp-on type)
•Bolt and nut tighteners
•Power supply connection tools (screwdriver or box wrench)
Note: Please also read the instructions that come with each of the test
instruments.
Checks to Make Before Installation
When a grounded plug is used:
Use the megohmmeter to measure the insulation resistance between
the cable assembly prongs and ground.
When connection leads are used:
With the megohmmeter, measure the insulation resistance between
each core lead and the ground lead.
Reference insulation resistance: 20MW or greater
Note: The reference insulation resistance (20MW or greater) is the
value when the pump is new or has been repaired. For the reference
value after installation, see Maintenance and Inspection.
DO NOT measure the insulation resistance with insulation resistance
tester for the following parts. It will cause damage (Model PSA 2 500).
CAUTION
Improper ways to measure insulation resistance
1.Between the plug prongs.
2.Between the electrodes on the level relay unit.
3.Between the electrodes on the level relay unit and the plug prongs.
See Graphic: wc_gr000258
1
2
3
wc_tx000121gb.fm12
wc_gr000258
PS 2 500 / PS 2 750 / PSA 2 500Operation
Precautions During Installation
Do not under any circumstances install or move the pump by
suspending it from the cable assembly. The cable may be damaged,
WARNING
CAUTION
4.3.1This pump series is offered with a variety of discharge fittings. Follow
causing electrical leakage, shock, or fire.
When installing the pump, pay close attention to its center of gravity
and weight. If it is not lowered into place correctly, it may fall and be
damaged or cause injury.
When transporting the pump by hand, be sure to employ manpower
commensurate with the weight of the pump. To avoid back injury when
lifting the pump, bend the knees to pick it up rather than bending your
back only.
procedures noted below to assure a proper discharge connection.
Threaded Discharge Fitting (BSP) –
Tighten hose coupling or discharge pipe securely and with proper
gaskets.
Quick Disconnect Coupling (QD) –
Assure coupling is tightened securely to pump discharge fitting and
companion coupling is securely fastened with proper gaskets.
Barbed Discharge Fitting (Barb) –
Place hose clamp over hose and push hose to the base of the
discharge fitting. Tighten the hose clamp to secure the hose in place.
4.3.2Avoid dropping the pump or other strong impact. Lift the pump by
holding it firmly with the hands or by attaching a rope or chain to the
handle.
Note: On cable assembly handling, see Electrical Wiring.
4.3.3Install the pump in a location with sufficient water level, where water
collects readily.
Note: See “Operating Water Level” for the water level necessary for
operation. The discharge end of the hose should be located higher
than the water surface. If the end of the hose is submerged, water may
flow back to the pump when the pump is stopped; and if the hose end
is lower than the water surface, water may overflow when the pump is
turned off.
4.3.4The hose should be run as straight as possible, since excessive
bending will hinder the water flow, preventing sufficient lift, and can
even cause the hose to become clogged with earth. If the hose is
crimped near the pump, air can become trapped in the pump and
cause idle running.
wc_tx000121gb.fm13
OperationPS 2 500 / PS 2 750 / PSA 2 500
If large quantities of earth are sucked up, damage resulting from
friction in the pump can lead to electrical leakage and shock.
CAUTION
4.3.5Use the pump in the upright position. To prevent the pump from
becoming submerged in mud, mount it on a block or other firm base if
necessary.
4.3.6If used in a permanent installation, where the pump is not readily
accessible after installation, please contact Wacker for a duplicate
nameplate to be installed at the wellhead or on the control box so that
it will be readily visible.
DO NOT lift or hang the pump by the level relay unit (1). It will lead to
damage and may cause leakage, electric shock, and fire (Model PSA
CAUTION
See Graphic: wc_gr000259
2 500).
1
wc_gr000259