Wacker Neuson PS 2 500, PS 2 750, PSA 2 500, PS2 800, PSA2 800 Operator's Manual

...
0154625en 003 0409
Pump
PS 2 500 PS 2 750 PSA 2 500
OPERATOR’S MANUAL
0154625EN
PS 2 500/PS 2 750/PSA 2 500 Table of Contents
1. Foreword 4
2. Safety Information 5
2.1 Operating and Electrical Safety ............................................................ 6
2.2 Information Labels ................................................................................ 6
3. Technical Data 7
3.1 Standard Specifications ........................................................................ 7
3.2 Operating Specifications (50 Hz) .......................................................... 8
3.3 Dimensions ........................................................................................... 9
4. Operation 10
4.1 Names of Parts ................................................................................... 10
4.2 Prior to operation ................................................................................ 11
4.3 Installation .......................................................................................... 11
4.4 Electrical Wiring .................................................................................. 15
4.5 Electrical Circuit Diagrams ................................................................. 17
4.6 Operation ............................................................................................ 20
5. Maintenance 25
5.1 Periodic Maintenance Table ............................................................... 25
5.2 Maintenance and Inspection .............................................................. 26
5.3 Disassembly/Reassembly .................................................................. 28
5.4 Disassembly ....................................................................................... 29
5.5 Reassembly ........................................................................................ 30
5.6 Troubleshooting .................................................................................. 31
wc_bo0154625003enTOC.fm 3
Foreword
1. Foreword
This manual provides information and procedures to safely operate and maintain this Wacker model. For your own safety and protection from injury, carefully read, understand and observe the safety instructions described in this manual.
Keep this manual or a copy of it with the machine. If you lose this manual or need an additional copy, please contact Wacker Corporation. This machine is built with user safety in mind; however, it can present hazards if improperly operated and serviced. Follow operating instructions carefully! If you have questions about operating or servicing this equipment, please contact Wacker Corporation.
The information contained in this manual was based on machines in production at the time of publication. Wacker Corporation reserves the right to change any portion of this information without notice.
All rights, especially copying and distribution rights, are reserved.
Copyright 2007 by Wacker Corporation.
No part of this publication may be reproduced in any form or by any means, electronic or mechanical, including photocopying, without express written permission from Wacker Corporation.
Any type of reproduction or distribution not authorized by Wacker Corporation represents an infringement of valid copyrights and will be prosecuted. We expressly reserve the right to make technical modifications, even without due notice, which aim at improving our machines or their safety standards.
4
PS 2 500 / PS 2 750 / PSA 2 500 Safety Information
2. Safety Information
This manual contains DANGER, WARNING, CAUTION, NOTICE and NOTE callouts which must be followed to reduce the possibility of personal injury, damage to the equipment, or improper service.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
DANGER
WARNING
CAUTION
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE: Used without the safety alert symbol, NOTICE indicates a hazardous situation which, if not avoided, could result in property damage.
Note: Contains additional information important to a procedure.
wc_si000040gb.fm 5
Safety Information PS 2 500 / PS 2 750 / PSA 2 500
2.1 Operating and Electrical Safety
To reduce risk of electric shock, connect only to a properly grounded,
WARNING
grounding-type receptacle.
Risk of electric shock - This pump has not been investigated for use in
swimming pool areas.
An acceptable motor-control switch shall be provided at the time of
installation according to local codes and regulations.
To reduce risk of electric shock, see instruction manual for proper
installation.
CAUTION: This pump may automatically restart. Prior to working on
the pump or control panel all supply circuits must be disconnected.
CAUTION: Risk of shock - Do not remove cord and strain relief.
2.2 Information Labels
Label Meaning
MADE IN TAIWAN
wc_si000040gb.fm 6
A nameplate listing the model number, item num­ber, revision number, and serial number is attached to each unit. Please record the informa­tion found on this plate so it will be available should the nameplate become lost or damaged. When ordering parts or requesting service infor­mation, you will always be asked to specify the model number, item number, revision number, and serial number of the unit.
PS 2 500 / PS 2 750 / PSA 2 500 Technical Data
3. Technical Data
Machines discussed in this manual:
Part No. PS2 500
0008793, 0008794 0008795, 0008796 0009176, 0009177 0009178, 0620124
PSA 2 500
0008787, 0008790 0008791, 0008792 0009179, 0009180 0009181, 0620125
PS2 750
0008797, 0008798 0008799, 0008800 0009182, 0009183 0009184, 0620126
3.1 Standard Specifications
Applicable Liquids, Consistency and Temperature
Pump Impeller Semi-Vortex Type: (PS 2 500, PSA 2 500)
Shaft Seal Double Mechanical Seal Bearing Shielded Ball Bearing
Motor Specification Dry Submersible Induction Motor (2-Pole)
Rain Water, Fountain Water, Ground Water,
Sand-Carrying Water
0–40°C (32–104°F)
Open Type: (PS 2 750)
Insulation Class E Protection System Miniature Protector: (PS 2 500, PSA 2 500)
Circle Thermal Protector: (PS 2 750)
Lubricant SAE 10W/20W
Such as: –Turbine Oil ISO VG #32 –Shell Victrolia Oil #27 –British Pet Energol THB #32 –Gulf Paramount #32 –Tellus #T22 Shell Oil –Shell Turbo T32
Connection Hose Coupling (Barb, BSP, QD–2")
wc_td000040gb.fm 7
Technical Data PS 2 500 / PS 2 750 / PSA 2 500
3.2 Operating Specifications (50 Hz)
Part No. PS 2 500 PSA 2 500 PS 2 750
Electric Power Rated Current Starting
Method Discharge Output Max. Head Max. Capacity
0008793 0008794 0008795 0008796 0009176 0009177 0620124
0009178
0008787 0008790 0008791 0008792 0009179 0009180 0620125
0009181
0008797 0008798 0008799 0008800 0009182 0009183 0620126
0009184
Pump
V/Ph/Hz 230/1/50 110/1/50 230/1/50 110/1/50 230/1/50 110/1/50
A
2.9 6.2 2.9 6.2 6.3 13.9 Capacitor-Run
mm (in.)
kW (Hp)
m (ft.)
L/min
(GPM)
0.48 (2/3) 0.75 (1) 11 (36) 16 (52.2)
220 (58) 276 (73)
50 (2)
Max. Pressure
Soild Size
mm (in.)
kg/cm
(psi)
2
1.19 (17) 1.83 (26)
6 (0.2)
Capacity Weight*
* The weight (mass) given above is the operating weight of the pump itself, not including the cable
assembly.
Kg (lbs.)
9.5 (21) 10.0 (22) 16.0 (35)
wc_td000040gb.fm 8
PS 2 500 / PS 2 750 / PSA 2 500 Technical Data
3.3 Dimensions
mm (in.)
185
(7.3)
185
(7.3)
185
(7.3)
185
(7.3)
200 (11)
185
(7.3)
229
(9)
PS 2 500
305 (12)
200 (11)
229
(9)
222
(8.8)
PSA 2 500
305 (12)
PS 2 750
414
(16.3)
wc_td000040gb.fm 9
Operation PS 2 500 / PS 2 750 / PSA 2 500
4. Operation
4.1 Names of Parts
See Graphic: wc_gr001185
1
2
3
4
5
6
7
8 9 10 11
12 13
14
wc_gr001185
Ref. Description Ref. Description
1. Lifting Handle 8. Seal-mechanical
2. Coupling 9. Lubricant
3. Oil Lifter 10. Seal-dust
4. Oil Plug 11. Sleeve
5. Cover-suction 12. Housing-oil
6. Strainer 13. Wear Ring
7. Cable Assembly 14. Impeller
wc_tx000121gb.fm 10
PS 2 500 / PS 2 750 / PSA 2 500 Operation
4.2 Prior to operation
When the pump is delivered, first perform the following checks:
Inspection While unpacking, inspect the product for damage during shipment, and
make sure all bolts and nuts are tightened properly.
Specification check Check the model number to make sure it is the product that was
ordered. Be certain it is the correct voltage and frequency.
Note: If there is any problem with the product as shipped, contact your nearest dealer or Wacker representative at once.
Product specifications Do not operate this product under any conditions other than those for
which it is specified. Failure to observe this precaution can lead to
CAUTION
electrical shock, current leakage, fire, water leakage or other problems.
4.3 Installation
If the pump is used for outdoor fountains, garden ponds and similar places, or to drain a swimming pool, the pump must be supplied by an isolating transformer or connected to a Residual Current Device (RCD)
WARNING
with a residual operating current not exceeding 30 mA. The pump must not be used when people are in the water. Leakage of pump lubricants may cause pollution of water. Proper plug must be provided according to local codes and standards.
Refer to wiring diagram. DO NOT use this pump in liquids other than water, such as oil, salt
water, or organic solvents. Use with a power supply voltage within ±5% of the rated voltage. DO NOT use in water temperatures outside the range of 0–40°C (32–
104°F) which can lead to failure, electrical leakage or shock. DO NOT use in the vicinity of explosive or flammable materials. Use only in fully assembled state.
Note: Consult your local dealer or Wacker representative before using with any liquids other than those indicated in this document.
wc_tx000121gb.fm 11
Operation PS 2 500 / PS 2 750 / PSA 2 500
Preparing for Installation
Before installing the pump at a work site, you will need to have the following tools and instruments ready:
Insulation resistance tester (megohmmeter)
AC voltmeter
AC ammeter (clamp-on type)
Bolt and nut tighteners
Power supply connection tools (screwdriver or box wrench)
Note: Please also read the instructions that come with each of the test instruments.
Checks to Make Before Installation
When a grounded plug is used: Use the megohmmeter to measure the insulation resistance between
the cable assembly prongs and ground. When connection leads are used: With the megohmmeter, measure the insulation resistance between
each core lead and the ground lead. Reference insulation resistance: 20MW or greater
Note: The reference insulation resistance (20MW or greater) is the value when the pump is new or has been repaired. For the reference value after installation, see Maintenance and Inspection.
DO NOT measure the insulation resistance with insulation resistance tester for the following parts. It will cause damage (Model PSA 2 500).
CAUTION
Improper ways to measure insulation resistance
1. Between the plug prongs.
2. Between the electrodes on the level relay unit.
3. Between the electrodes on the level relay unit and the plug prongs.
See Graphic: wc_gr000258
1
2
3
wc_tx000121gb.fm 12
wc_gr000258
PS 2 500 / PS 2 750 / PSA 2 500 Operation
Precautions During Installation
Do not under any circumstances install or move the pump by suspending it from the cable assembly. The cable may be damaged,
WARNING
CAUTION
4.3.1 This pump series is offered with a variety of discharge fittings. Follow
causing electrical leakage, shock, or fire.
When installing the pump, pay close attention to its center of gravity and weight. If it is not lowered into place correctly, it may fall and be damaged or cause injury.
When transporting the pump by hand, be sure to employ manpower commensurate with the weight of the pump. To avoid back injury when lifting the pump, bend the knees to pick it up rather than bending your back only.
procedures noted below to assure a proper discharge connection.
Threaded Discharge Fitting (BSP) –
Tighten hose coupling or discharge pipe securely and with proper gaskets.
Quick Disconnect Coupling (QD) –
Assure coupling is tightened securely to pump discharge fitting and companion coupling is securely fastened with proper gaskets.
Barbed Discharge Fitting (Barb) –
Place hose clamp over hose and push hose to the base of the discharge fitting. Tighten the hose clamp to secure the hose in place.
4.3.2 Avoid dropping the pump or other strong impact. Lift the pump by holding it firmly with the hands or by attaching a rope or chain to the handle.
Note: On cable assembly handling, see Electrical Wiring.
4.3.3 Install the pump in a location with sufficient water level, where water collects readily.
Note: See “Operating Water Level” for the water level necessary for operation. The discharge end of the hose should be located higher than the water surface. If the end of the hose is submerged, water may flow back to the pump when the pump is stopped; and if the hose end is lower than the water surface, water may overflow when the pump is turned off.
4.3.4 The hose should be run as straight as possible, since excessive bending will hinder the water flow, preventing sufficient lift, and can even cause the hose to become clogged with earth. If the hose is crimped near the pump, air can become trapped in the pump and cause idle running.
wc_tx000121gb.fm 13
Operation PS 2 500 / PS 2 750 / PSA 2 500
If large quantities of earth are sucked up, damage resulting from friction in the pump can lead to electrical leakage and shock.
CAUTION
4.3.5 Use the pump in the upright position. To prevent the pump from becoming submerged in mud, mount it on a block or other firm base if necessary.
4.3.6 If used in a permanent installation, where the pump is not readily accessible after installation, please contact Wacker for a duplicate nameplate to be installed at the wellhead or on the control box so that it will be readily visible.
DO NOT lift or hang the pump by the level relay unit (1). It will lead to damage and may cause leakage, electric shock, and fire (Model PSA
CAUTION
See Graphic: wc_gr000259
2 500).