Installation instruction
Microwave
Construction type 60-381
The appliance should be installed by qualified personnel only.
Each step must be carried out and checked in full in the order specified.
Validity
These installation instructions apply to the models:
24006, 24008
General notes
If installing into a combustible material, the guidelines and standards for low voltage installations and fire
protection must be strictly observed.
Identification plate
▸ Open appliance door.
400010800366
22/09/2015
J24006113-R02
– The identification plate is located on the left above the cooking
space (see illustration).
Electrical connections
Electrical connections must be carried out by qualified personnel in accordance with the guidelines and
standards for low-voltage installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and socket devices, circuit breakers and fusible cut-outs which are accessible after
installation and which have all-poles switching are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and fault-free operation. After installation, live parts
and cables with basic insulation must not be accessible. Check old installations.
▸ The appliance is designed for use up to a max. altitude of 2000 m above sea level.
▸ Refer to the identification plate for information on the required mains voltage, current type and fuse protection.
The mains plug must not be cut off.
1
Installation instruction
300
(470)
378
597
445
~85°
=
=
50
≥ 550
600
560–568
20
~45
545
S
S
X
374
Detail X
374
Niche
378
Appliance
560–568
50
EURO 594
SMS 762
EURO 380
SMS 381
EURO 974
SMS 1143
W
≥
550
560–568
EURO 600
SMS 762
EURO 374
SMS 381
EURO 974
SMS 1143
≥
550
50
W
Microwave
Construction type 60-381
Installation
It is not possible to install the appliance above an extractor oven because of the extraction pipes that lead upwards.
Minimum installation height: Keep 850mm distance from the floor to the bottom edge of the microwave!
Installing
400010800366
22/09/2015
J24006113-R02
1. Place appliance in front of the niche and insert the mains plug.
2. Carefully slide appliance into the niche until it is flush with the front of the cabinets, ensuring that the mains cable is
not pinched.
3. Open the appliance door and from the front secure the appliance at the sides with the 4 enclosed screws S.
Installing with an oven in the same niche
If an oven is installed in the same niche (above or below the appliance), use angle bracket set 60 W to support
the upper appliance.
Below oven Above oven
2