Installation instructions
Heat pump dryer One-family household
For Service and Spare Part Information please contact: Manfred Schulz, Technical Manager V-ZUG AUSTRALIA PTY LTD, c/o C.W. Stirling 6th floor 90 William Street, Melbourne, VIC 3000 manfred.schulz@vzug.com.au Tel/ Fax +61 3 9723 5790, Mob +61 400 088336
The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in the order specified.

Validity

These installation instructions apply to the model: 958

Transport

The appliance is only to be transported in the upright position! Transporting it in any other position will result in damage to the appliance! When carried carefully, without being shaken, the appliance may be tilted to the left by a maximum of 90° (viewed from the front). The appliance must be allowed to stand in the standard operating position for about 2 hours before using the heat pump. Failure to observe this can result in damage to the appliance.
Front
J958.370-0
29.4.10 ITH
Front
Front
Front,
upside down Side
Back
1
Page 2
Installation instructions
Heat pump dryer One-family household
For Service and Spare Part Information please contact: Manfred Schulz, Technical Manager V-ZUG AUSTRALIA PTY LTD, c/o C.W. Stirling 6th floor 90 William Street, Melbourne, VIC 3000 manfred.schulz@vzug.com.au Tel/ Fax +61 3 9723 5790, Mob +61 400 088336

Identification plate

A Open the appliance door and the cover.
– The identification plate is located bottom right behind the cleaning cover.

Installation accessories supplied

The necessary installation accessories are located in the drum.
Article Article no. Number See installation step
Condensate drain kit W5.5845 1 4. Connect condensate drain
Installation plate (W5.0542) incl. screw material (S) and double-sided adhesive tape
J958.370-0
29.4.10 ITH
S

Room conditions / ventilation

Do not obstruct the appliance’s ventilation slits to ensure that there is an ample supply of air.
The extracted air must not be fed into a chimney which is used for exhausting fumes from appliances burning gas or other fuels.
The room must be well ventilated to ensure that the room temperature does not exceed 35 °C.
The room temperature should be kept as low as possible to ensure the economic running of the appliance. Critical is a room temperature of 35 °C and over. This prolongs the duration of the programmes.
If the volume of the room in which the appliance is located is at least 20 m³ when closed: Condensation may form on thermal bridges! The room must be aired (by opening the door to or a window in the room) between consecutive drying programmes!
If the volume of the room in which the appliance is located is less than 20 m³: There must be air inlet and outlet openings (open window, ventilation grille or slits in the door, ventilation system) to the adjacent room or to the outside.

Installation

Work steps 1–5 must be carried out in full in the order specified.
1. Positioning the installation plate
Use the installation plate to install the appliance. This plate fixes the appliance in position (for both free-standing appliances and appliances placed in a niche).
The appliance must not be installed behind a lockable door, a sliding door or a door with a hinge on the opposite to that of the appliance, in such a way that a full opening of the appliance door is restricted.
A Raise the appliance slightly at the front and pull it forward, away from the installation plate. A Secure the installation plate to the location you wish to install the appliance using 4 screws. On smooth and clean floors, you can
affix the installation plate (double-sided adhesive tape supplied).
A Dampen the mounting slots on the installation plate with water.
2
Page 3
Installation instructions
Heat pump dryer One-family household

Free-standing position

If a tumble dryer and a washing machine are positioned side by side, keep a distance of min. 5 mm between installation plates and min. 3 mm to walls.
min. 3
597
min. 550 *
505
For Service and Spare Part Information please contact: Manfred Schulz, Technical Manager V-ZUG AUSTRALIA PTY LTD, c/o C.W. Stirling 6th floor 90 William Street, Melbourne, VIC 3000 manfred.schulz@vzug.com.au Tel/ Fax +61 3 9723 5790, Mob +61 400 088336
min. 5
595
50
J958.370-0
29.4.10 ITH
min. 5

Positioning in a niche

A Centre the installation plate in the niche.
Cut-out for lateral connections, to the left or right side min. 100 × 100 mm
The heat given off from the rear of the appliance must be lead out of the niche. For this the rear cover parts must be removed. Mount ventilation grille P33.002 and ensure there is a supply of fresh air via the connection opening.
400 cm²
Ventilation grille
min. 600 *
Niche depth
min. 600
Niche width
min. 50
* This only applies if no plumbing fittings are to be installed behind the appliance.
Add another 20 mm if the condensed water hose leads away to the left.
400 cm²
Ventilation grille
min. 860
Niche height
min. 1705
Niche height
3
Page 4
Installation instructions
Heat pump dryer One-family household
For Service and Spare Part Information please contact: Manfred Schulz, Technical Manager V-ZUG AUSTRALIA PTY LTD, c/o C.W. Stirling 6th floor 90 William Street, Melbourne, VIC 3000 manfred.schulz@vzug.com.au Tel/ Fax +61 3 9723 5790, Mob +61 400 088336
J958.370-0
29.4.10 ITH
2. Levelling
A Roughly adjust the rear adjuster feet. A To ensure smooth, fault-free operation, the appliance must be perfectly vertical. Use a
spirit level to position the appliance.
A Slide the appliance in. Finely adjust the front adjuster feet until all 4 feet are standing
firmly on the floor. – The appliance must not wobble.
3. Electrical connections
Electrical connections must be carried out by trained electricians in accordance with the guidelines and standards for low volt­age installations and the specifications of the local electricity supply companies. A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. A mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Old installations should always be checked. If the appliance is supplied from a cord extension set or electrical portable outlet device the cord extension set or electrical portable outlet device should be positioned so it is not subject to splashing or ingress of moisture.
A Information on the necessary mains voltage, type of current and fuse protection is to be obtained from the identification plate.

Connection cable

Colour code
L1 brown
blue
N
yellow/green

Error messages «U..»

Disconnect the appliance from the mains and control the wiring.
230 V~ 50 Hz, 10 A
L1
N
3 × 1 mm²
4
Page 5
Installation instructions
Heat pump dryer One-family household
4. Connect condensate drain
When installing the drain hose, protect it against damage and bending! For that, use a hose clip 8.086.8039.
B
A
For Service and Spare Part Information please contact: Manfred Schulz, Technical Manager V-ZUG AUSTRALIA PTY LTD, c/o C.W. Stirling 6th floor 90 William Street, Melbourne, VIC 3000 manfred.schulz@vzug.com.au Tel/ Fax +61 3 9723 5790, Mob +61 400 088336
BC
J958.370-0
29.4.10 ITH
D
C
B
A Loosen screw A. A Remove cover B.
A Push the supplied drain hose C (2 m)
through the hole in the cover B.
A Push on to the pump connection piece
A Replace cover B. A Place hose around retainer D.
and secure with a hose clip.

Single connections

Connection to sink drain trap Drain into fixed upright outflow pipe
The max. pumping height of the pump is 1.2 m
min. 800
Cannot be connected to a double drain trap.There must be a separate concealed drain trap for each appliance.
min. 350

Washer-dryer combinations

Can be connected to a double drain trap.
Washer-dryer tower Installation side by side
with combi drainage set
W5.4917
max. 700
with drainage into fixed
upright outflow pipe
max. 700
5
with combi drainage set
W5.4917
max. 700
Page 6
Installation instructions
Heat pump dryer One-family household
For Service and Spare Part Information please contact: Manfred Schulz, Technical Manager V-ZUG AUSTRALIA PTY LTD, c/o C.W. Stirling 6th floor 90 William Street, Melbourne, VIC 3000 manfred.schulz@vzug.com.au Tel/ Fax +61 3 9723 5790, Mob +61 400 088336
J958.370-0
29.4.10 ITH
5. Using for the first time
When the appliance is connected to the power supply for the first time, it is possible to select a function test. The purpose of the function test is to check the installation and it lasts about 3 minutes. For the function test the appliance must not to have been standing in the normal operating position for approx. 2 hours as the heat pump is not started. The function test can therefore be selected immediately after installation.
The function test cannot be aborted by an interruption of the mains supply.
Once the function test has been run, it can no longer be selected and the appliance enters the normal selection mode.
Start function test
A Connect appliance and wait for to show in the digital display.
A Start the function test with button .
The function test can be interrupted in 2 ways:
1. Open the appliance door.
flashes in the digital display.
– Indicator lights for buttons and flash after closing the appliance door.
Or
2. Press the button.
– Indicator lights for buttons and flash.
Continue the function test:
A Press the button.
– The remaining time shows in the digital display, e.g. .
Abort function test:
A By pressing the button the function test is aborted and all displays go out.
End of function test:
– All displays go out on completion of the function test.
The appliance is only ready to operate after the required waiting time of approx. 2 hours in the normal operating position. Failure to observe this can result in damage to the appliance.