V-ZUG 6400465005 Installation Guide

0 (0)

1011458-R03

Installation instructions

25/06/2018

Range hood

Mode: Extraction / Recirculation

1011458-R03

DSTS9

The appliance should be installed by qualified personnel only.

Each step must be carried out and checked in full in the order specified.

Validity

64004 (DSTS9, construction width 90 cm)

General notes

Identification plate

Remove the grease filters. The identification plate is located on the inside of the appliance.

Installation accessories supplied

All fixing elements are contained in the scope of delivery.

Mains cable

12 self-tapping screws 3.5 × 9.5 mm

Lower angle bracket

6 screws M4 × 8 mm

Upper angle bracket

6 screws 4 × 15 mm

Angle brackets

Accessories: Recirculation box

(are not used)

 

Extraction mode

The extracted air must not be fed into a chimney which is used for exhausting fumes from appliances burning gas or other fuels.

Observe the local fire regulations.

Recirculation mode

The air outlet grille must not be covered during operation.

1

V-ZUG 6400465005 Installation Guide

1011458-R03

Installation instructions

25/06/2018

Range hood

Mode: Extraction / Recirculation

1011458-R03

DSTS9

Dimensions

Cannot be installed in conjunction with a gas hob.

Recessed installation variant

120

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

 

250

8

 

 

 

 

 

 

 

116

400

 

2

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

332

 

 

 

 

 

 

 

 

 

102

 

 

98

 

 

 

 

 

 

2.4

 

 

 

332

 

 

 

2

 

 

 

646

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

166

 

 

 

 

 

 

 

 

 

 

 

17

 

 

(ø150)

 

 

 

 

 

 

 

 

 

 

 

 

10–200

 

 

-

 

 

 

 

 

8

 

 

 

 

1

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

108

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

≥30

 

 

 

≥660

 

 

 

 

 

 

 

5

3

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flush installation variant

 

 

7

 

 

108

R0–5

R5

4

 

 

812

 

 

884

 

124

4

 

884

 

 

R0–5

124

812

 

 

 

7

 

108

 

 

 

R5

124

 

 

108

7

 

1The fan can be rotated for mounting. The exhaust air can thus be extracted upwards, left, right or downwards. The fan can also be mounted in the same position at the back of the appliance. If the fan is mounted at the back of the appliance, the back panel of the cabinet has to be cut out in the mounting area and sufficient installation space must be provided behind the cabinet.

2The electrics can, if required, be positioned to the left of the fan, on the hood body or in the cabinet.

3Ensure that the material is sufficiently stable.

4Stepped milling required if installed flush in a work surface made of natural stone (granite, marble). Exhaust air connection ø150 mm.

2

1011458-R03

Installation instructions

25/06/2018

Range hood

Mode: Extraction / Recirculation

1011458-R03

DSTS9

Installation

Carefully insert the hood body 1 in the prepared cut-out 2 (see

Dimensions).

1

For flush installation, level the hood body at the right height (using spacer set H6.0330).

2

Fasten the lower brackets 3 to the housing 5 of hood body 1 us-

ing two screws 4 for each bracket so that the feet 6 rest on the

base of the cabinet.

1

The brackets can also be rotated for mounting.

5

3

4

6

3.5×9.5 mm

3

Loading...