V-ZUG 6400465005 Installation Guide

Installation instructions
1011458-R03
Range hood Mode: Extraction / Recirculation DSTS9
The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in the order specified.
Validity
64004 (DSTS9, construction width 90 cm)
General notes
Identification plate
Remove the grease filters. The identification plate is located on the inside of the appliance.
Installation accessories supplied
All fixing elements are contained in the scope of delivery.
Mains cable 12 self-tapping screws 3.5 × 9.5mm
Lower angle bracket 6 screws M4 × 8mm
1011458-R03
25/06/2018
Upper angle bracket 6 screws 4 × 15mm
Angle brackets (are not used)
Accessories: Recirculation box
Extraction mode
The extracted air must not be fed into a chimney which is used for exhausting fumes from appliances burning gas or other fuels. Observe the local fire regulations.
Recirculation mode
The air outlet grille must not be covered during operation.
Installation instructions
1011458-R03
120
8
8
0
7
6
5
4
116
65
8
0
2
250
102
98
332
(ø150)
≥660
≥30
8
1
2
108
-1
30
3
1
2
10–200
646
2.4
400
332
16617
R
0
5
124
R5
884
108
812
7
884
812
108
7
124
R5
108
7
124
4
4
R0–5
R0–5
Range hood Mode: Extraction / Recirculation DSTS9
Dimensions
Cannot be installed in conjunction with a gas hob.
Recessed installation variant Flush installation variant
1011458-R03
25/06/2018
1 The fan can be rotated for mounting. The exhaust air can thus be extracted upwards, left, right or downwards. The fan can also
2 The electrics can, if required, be positioned to the left of the fan, on the hood body or in the cabinet. 3 Ensure that the material is sufficiently stable. 4 Stepped milling required if installed flush in a work surface made of natural stone (granite, marble).
be mounted in the same position at the back of the appliance. If the fan is mounted at the back of the appliance, the back panel of the cabinet has to be cut out in the mounting area and sufficient installation space must be provided behind the cabinet.
Exhaust air connection ø150mm.
Installation instructions
1011458-R03
3.5×9.5 mm
Range hood Mode: Extraction / Recirculation DSTS9
Installation
Carefully insert the hood body 1 in the prepared cut-out 2 (see
Dimensions).
For flush installation, level the hood body at the right height (us-
ing spacer set H6.0330).
1011458-R03
25/06/2018
Fasten the lower brackets 3 to the housing 5 of hood body 1 us-
ing two screws 4 for each bracket so that the feet 6 rest on the base of the cabinet.
The brackets can also be rotated for mounting.
Loading...