Item # __________________________
MODEL VH3616D
C.S.I. Section 11420
DIRECT STEAM CONVECTION STEAMER
ON CABINET BASE
■■ VH3616D 36" wide base
STANDARD FEATURES
■ Two stainless steel cooking compartments with coved
interior corners. Each compartment accepts sixteen
1" deep, eight 21/2" deep or four 4" deep 12" x 20" pans.
■ 11/4" drain in each compartment.
■ Heavy duty stainless steel "slammable" doors can be
opened and closed at anytime during the cooking cycle.
Steam shuts off when door(s) are opened.
■ Compartment controls include 60 minute dial timer with
buzzer, green "ready" and red "cooking" indicator lights.
■ Convection steamer mounted on 28" high base cabinet with
stainless steel front full height doors, slip-off stainless
steel side and aluminized steel rear panel with welded
6" stainless steel legs rear with flange foot and front
with bullet.
■ Direct steam supply at 10 to 50 psi with a flow of 200 lbs. of
steam/hr.
■ One year limited parts and labor warranty.
Vulcan-Hart Co.
ISO9001
A2780
MODELS: VH3616D
SPECIFICATIONS:
Direct steam convection steamer, Vulcan-Hart Model No.
VH3616D. Two stainless steel cooking compartments with
coved interior corners. Each compartment accepts sixteen 1"
deep, eight 2
in each compartment. Heavy duty stainless steel "slammable"
doors can be opened and closed at anytime during the cooking
cycle. Steam shuts off when door(s) are opened. Compartment
controls include 60 minute dial timer with buzzer, green "ready"
and red "cooking" indicator lights. Convection steamer mounted
on 28" high base cabinet with stainless steel frame, front full
height doors, slip-off stainless steel side and aluminized steel
rear panel with 6" stainless steel legs, rear flanged feet. Direct
steam supply at 10 to 50 psi with a flow of 221 lbs. of steam/hr.
Exterior dimensions: 36"w x 33"d x 66"h.
U L listed. NSF listed.
1
/2" deep or four 4" deep 12" x 20" pans. 11/4" drain
OPTIONS
■■ Correction facility package:
a. Security type tamper resistant fasteners with tack welds.
b. Control cover with hasp (lock by others).
c. Cabinet door with hasp (lock by others).
d. Flanged feet.
■■ Step down transformer for control circuit if higher than
120 volts.
■■ Second year extended limited parts & labor warranty.
ACCESSORIES
■■ Stainless steel cabinet back.
■■ Removable 12 x 20 sliding shelf (Qty.____).
Direct Steam Convection Steamer on Cabinet Base
F-32615 (5-04)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
MODEL VH3616D
DIRECT STEAM CONVECTION STEAMER
ON CABINET BASE
DIRECT STEAM DATA:
Steam supply to the steamer must:
1. Maintain a steady 10 to 50 psi flow under operating conditions.
2. Have a minimum flow rate of 200 lbs. per hour, dry steam.
3. Be adequately trapped to provide dry steam.
4. Provide a service shut-off valve.
NOTE:
• Dimensions which locate the above connections have a tolerance of
+ or -3" (+ or -75 mm).
• Installation of backflow preventers, vacuum breakers and other specific code requirements is the responsibility of the owner and installer.
It is the responsibility of the owner and installer to comply with local
codes.
• Plastic drains are not recommended due to inherent limited temperatures of the plastic. Boiler purge temperatures may exceed 180°F. The
installer may be required to provide means to reduce boiler purge
water temperature to be that of the condensate temperature of 140°F
or less.
• This appliance is manufactured for commercial installation only and is
not intended for home use.
SERVICE CONNECTIONS:
Steam Supply: 3/4" NPT for 10 - 50 psi direct steam.
Electric Connection for Controls: 120/60/1, 300 watt maximum
power supply with grounding wire required. (For other than 120
volt supply, consult factory for location of this conneciton.)
Drain: Condenser box, compartment and boiler, 2" NPT. (Provide
an open air gap type drain within 12" of condenser box and for best
results at a distance so that steam vapors will not enter the steamer
from underneath the control area. Do not connect solidly to any
drain connection.)
Cold Water Connection:3/8" NPT for condensate box. Inlet water
pressure between 20 and 80 psi.
PAN CAPACITIES (Per compartment)
1" deep 21/2" deep 4" deep
16 8 4
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and
specifications without notice.
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
F-32615 (5-04)
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
Printed On Recycled Paper