Shown with optional spring assist cover
Item # C.S.I. Section 11420
STEAM
VGLT SERIES
GAS TILTING 2⁄3 JACKETED KETTLE
VG LT2 0 80,000 BTU/hr., 20 gallon capacity.
VG LT40 100,000 BTU/hr., 40 gallon capacity.
VG LT6 0 120,000 BTU/hr., 60 gallon capacity.
STANDARD FEATURES
Self generating gas red power burner, all welded type ■
304 stainless steel, 2⁄3 jacketed tilting steam kettle.
Fully welded hemispheric bottom kettle with type 304 ■
stainless steel jacket and liner. (Type 316 stainless steel liner
20 & 40 gallons only). Jacket tested to 50 psi (3.4 kg/cm2).
Factory charged with chemically pure water, rust inhibitor, and ■
anti-freeze for protection against freezing to -30°F.
Kettle exterior is fully insulated. ■
Kettles mounted on trunnions connected to the control and ■
gear consoles. The worm gear tilting mechanism is self
locking and allows the kettle to tilt a full 90°. Trunnion cover
with provision for faucet.
Recessed control panel located on front of kettle. Controls ■
include direct immersion thermostat, water sight glass,
cooking light, pressure gauge and electronic ignition with
ignitions indicator light.
Safety features include low water cut-off, pressure relief valve, ■
pressure switch and gas shut-off valve.
Requires a 120 volt, 60 Hz, 1 phase power supply, 3.0 amp. 6' ■
cord and plug supplied.
3
■
/4" rear gas connection with gas pressure regulator.
One year limited parts and labor warranty. ■
SPECIFICATIONS
Self generating gas red power burner, all welded type 304,
2
⁄3 jacketed tilting steam kettle, Vulcan-Hart Model No. ( VGLT20)
(VGLT40) (VGLT60). Fully welded hemispherical bottom kettle with
type 304 stainless steel jacket and lining. (Type 316 stainless steel
liner 20 & 40 gallons only.) Jacket tested to 50 psi (3.4 kg/cm2).
Factory charged with chemically pure water, rust inhibitor, and
antifreeze for protection against freezing to -30°F. Kettle exterior
is fully insulated. Kettles mounted on trunnions connected to the
control and gear consoles. The worm gear tilting mechanism is
self locking and allows the kettle to tilt a full 90°. Trunnion cover
with provision for faucet. Recessed control panel located on front
of kettle. Controls include direct immersion thermostat, water sight
glass, cooking light, pressure gauge and electronic ignition with
ignitions indicator light. Safety features include low water cutoff, pressure relief valve, pressure switch and gas shut-off valve.
Requires a 120 volt, 60 Hz, 1 phase power supply, 3.0 amp. 6'
cord and plug supplied. 3⁄4" rear gas connection with gas pressure
regulator.
CSA design certied. NSF listed. Meets ASME code.
SPECIFY TYPE OF GAS WHEN ORDERING.
SPECIFY ALTITUDE WHEN ABOVE 2,000 FT.
OPTIONS
Spring assist cover.
Spring assist cover with condensate ring.
Two piece hinged cover.
Correction facility package.
a. Controls protected by lockable cover (lock by others).
b. Security type tamper resistant fasteners with tack welds.
c. Perforated ue cover.
d. Stainless steel cover over draw-off with chain.
Tilting kettle strainer.
2" draw-off valve with perforated strainer.
3" draw-off valve with perforated strainer.
Type 316 stainless steel liner, 60 gallons.
Second year extended limited parts and labor warranty.
ACCESSORIES (Packaged & Sold Separately)
18" double jointed single pantry faucet.
18" double jointed double pantry faucet.
Double pantry washdown hose with 16" add-on faucet with
backow preventer.
Double pantry washdown hose with backow preventer.
Double pantry pot ller and backow preventer.
Contour measuring strip.
Triple perforated stainless steel basket assembly.
Draw-off valve strainer, solid.
Clean-up kit; includes draw-off brush, clean-up brush w/36"
handle and paddle scraper w/40" handle with nylon blade.
Stainless steel 48" wire whip.
a divisi on of IT W Food Equ ipmen t Group LLC
P.O. Box 696 ■ Louisville, KY 40201 ■ Toll-free: 1-800-814-2028 ■ Local: 502-778-2791 ■ Quote & Order Fax: 1-800-444-0602
F-32051 (03/10)
STEAM
VGLT SERIES
GAS TILTING 2⁄3 JACKETED KETTLE
IMPORTANT:
1. A pressure regulator sized for this unit is included.
Minimum supply pressure: Natural gas 7" W.C. Propane
11" W.C.
2. Gas line connecting to unit must be 3⁄4" or larger. If exible
connectors are used, the inside diameter must be at least
the same as the 3⁄4" iron pipe and rated for the correct gas
input.
3. Requires 120 volt, 60 Hz, 1 phase electrical connection.
Furnished with 6' cord and 3 prong plug. 3 amp total draw.
4. An adequate ventilation system is required for commercial
cooking equipment. Information may be obtained by
writing to the National Fire Protection Association,
Batterymarch Park, Quincy, MA 02269. When writing, refer
to NFPA No. 96.
5. These units are manufactured for installation in accordance
with ANSZ223.1a (latest edition), National Fuel Gas
Code. Copies may be obtained from the American Gas
Association, 1515 Wilson Blvd., Arlington, VA 22209.
6. Equipment clearance: Combustible Non-Combustible
Rear 4" 4"
Right 0" 0"
Left 0" 0"
Floor N/A 6"
7. This appliance is manufactured for commercial installation
only and is not intended for home use.
MODEL
NO.
VG LT2 0 80,000
VG LT40 100,000
VG LT6 0 120,000
BTU/HR.
INPUT
BRIMFUL
CAPACIT Y*
20 gal., 80 qts.
76 liters
40 gal., 160 qts.
152 liters
60 gal., 240 qts.
227 liters
4 OZ.
SVGS. A B C D E F G H J K L M
161⁄
761/
161⁄
419
177⁄
454
401⁄
102 0
411⁄
2
105 4761930
451⁄
8
115 6822083
8
2
2
194 3
2
2
41924610112801025432813
71⁄
221⁄
151⁄
394
191⁄
496
2
565
221⁄
2
565
2
4
1901230535889
51⁄
2
4
1401538138965
640
1280
1920
20
508
26
660
30
762
481⁄
1222
541⁄
1378
581⁄
1378
405⁄
8
103 219483
435⁄
4
110 8
455⁄
8
110 8
8
8
8
* Working capacity 70% to 80% of brimful depending on model.
a divisi on of IT W Food Equ ipmen t Group LLC
P.O. Box 696 ■ Louisville, KY 40201 ■ Toll-free: 1-800-814-2028 ■ Local: 502-778-2791 ■ Quote & Order Fax: 1-800-444-0602
F-32051 (03/10)
NOTE: In line w ith its p olicy to continually imp rove its products, Vulcan rese rves the right to change materi als and s pecicatio ns without noti ce.
301⁄
775
301⁄
775
303⁄
772
2
2
8