Vulcan Hart VGLT20 General Manual

Shown with optional spring assist cover
Item # C.S.I. Section 11420
STEAM
VGLT SERIES
GAS TILTING 2⁄3 JACKETED KETTLE
VG LT2 0 80,000 BTU/hr., 20 gallon capacity. VG LT40 100,000 BTU/hr., 40 gallon capacity. VG LT6 0 120,000 BTU/hr., 60 gallon capacity.
STANDARD FEATURES
Self generating gas red power burner, all welded type
304 stainless steel, 2⁄3 jacketed tilting steam kettle.
Fully welded hemispheric bottom kettle with type 304
stainless steel jacket and liner. (Type 316 stainless steel liner 20 & 40 gallons only). Jacket tested to 50 psi (3.4 kg/cm2).
Factory charged with chemically pure water, rust inhibitor, and
anti-freeze for protection against freezing to -30°F.
Kettle exterior is fully insulated.
Kettles mounted on trunnions connected to the control and
gear consoles. The worm gear tilting mechanism is self locking and allows the kettle to tilt a full 90°. Trunnion cover with provision for faucet.
Recessed control panel located on front of kettle. Controls
include direct immersion thermostat, water sight glass, cooking light, pressure gauge and electronic ignition with ignitions indicator light.
Safety features include low water cut-off, pressure relief valve,
pressure switch and gas shut-off valve.
Requires a 120 volt, 60 Hz, 1 phase power supply, 3.0 amp. 6'
cord and plug supplied.
3
/4" rear gas connection with gas pressure regulator.
One year limited parts and labor warranty.
SPECIFICATIONS
Self generating gas red power burner, all welded type 304,
2
⁄3 jacketed tilting steam kettle, Vulcan-Hart Model No. ( VGLT20) (VGLT40) (VGLT60). Fully welded hemispherical bottom kettle with type 304 stainless steel jacket and lining. (Type 316 stainless steel liner 20 & 40 gallons only.) Jacket tested to 50 psi (3.4 kg/cm2). Factory charged with chemically pure water, rust inhibitor, and antifreeze for protection against freezing to -30°F. Kettle exterior is fully insulated. Kettles mounted on trunnions connected to the control and gear consoles. The worm gear tilting mechanism is self locking and allows the kettle to tilt a full 90°. Trunnion cover with provision for faucet. Recessed control panel located on front of kettle. Controls include direct immersion thermostat, water sight glass, cooking light, pressure gauge and electronic ignition with ignitions indicator light. Safety features include low water cut­off, pressure relief valve, pressure switch and gas shut-off valve. Requires a 120 volt, 60 Hz, 1 phase power supply, 3.0 amp. 6' cord and plug supplied. 3⁄4" rear gas connection with gas pressure regulator.
CSA design certied. NSF listed. Meets ASME code.
SPECIFY TYPE OF GAS WHEN ORDERING. SPECIFY ALTITUDE WHEN ABOVE 2,000 FT.
OPTIONS
Spring assist cover. Spring assist cover with condensate ring. Two piece hinged cover.
Correction facility package. a. Controls protected by lockable cover (lock by others). b. Security type tamper resistant fasteners with tack welds. c. Perforated ue cover. d. Stainless steel cover over draw-off with chain.
Tilting kettle strainer.
2" draw-off valve with perforated strainer.
3" draw-off valve with perforated strainer.
Type 316 stainless steel liner, 60 gallons.
Second year extended limited parts and labor warranty.
ACCESSORIES (Packaged & Sold Separately)
18" double jointed single pantry faucet.
18" double jointed double pantry faucet.
Double pantry washdown hose with 16" add-on faucet with
backow preventer.
Double pantry washdown hose with backow preventer.
Double pantry pot ller and backow preventer.
Contour measuring strip.
Triple perforated stainless steel basket assembly.
Draw-off valve strainer, solid.
Clean-up kit; includes draw-off brush, clean-up brush w/36"
handle and paddle scraper w/40" handle with nylon blade.
Stainless steel 48" wire whip.
P.O. Box 696 ■ Louisville, KY 40201 ■ Toll-free: 1-800-814-2028 ■ Local: 502-778-2791 ■ Quote & Order Fax: 1-800-444-0602
F-32051 (03/10)
STEAM
VGLT SERIES
GAS TILTING 2⁄3 JACKETED KETTLE
IMPORTANT:
1. A pressure regulator sized for this unit is included. Minimum supply pressure: Natural gas 7" W.C. Propane 11" W.C.
2. Gas line connecting to unit must be 3⁄4" or larger. If exible connectors are used, the inside diameter must be at least the same as the 3⁄4" iron pipe and rated for the correct gas input.
3. Requires 120 volt, 60 Hz, 1 phase electrical connection. Furnished with 6' cord and 3 prong plug. 3 amp total draw.
4. An adequate ventilation system is required for commercial cooking equipment. Information may be obtained by writing to the National Fire Protection Association,
Batterymarch Park, Quincy, MA 02269. When writing, refer to NFPA No. 96.
5. These units are manufactured for installation in accordance with ANSZ223.1a (latest edition), National Fuel Gas Code. Copies may be obtained from the American Gas Association, 1515 Wilson Blvd., Arlington, VA 22209.
6. Equipment clearance: Combustible Non-Combustible
Rear 4" 4" Right 0" 0" Left 0" 0" Floor N/A 6"
7. This appliance is manufactured for commercial installation only and is not intended for home use.
MODEL
NO.
VG LT2 0 80,000
VG LT40 100,000
VG LT6 0 120,000
BTU/HR.
INPUT
BRIMFUL
CAPACIT Y*
20 gal., 80 qts.
76 liters
40 gal., 160 qts.
152 liters
60 gal., 240 qts.
227 liters
4 OZ.
SVGS. A B C D E F G H J K L M
161⁄
761/
161⁄
419
177⁄
454
401⁄
102 0
411⁄
2
105 4761930
451⁄
8
115 6822083
8
2
2
194 3
2
2
41924610112801025432813
71⁄
221⁄
151⁄
394
191⁄
496
2
565
221⁄
2
565
2
4
1901230535889
51⁄
2
4
1401538138965
640
1280
1920
20
508
26
660
30
762
481⁄
1222
541⁄
1378
581⁄
1378
405⁄
8
103 219483
435⁄
4
110 8
455⁄
8
110 8
8
8
8
* Working capacity 70% to 80% of brimful depending on model.
P.O. Box 696 ■ Louisville, KY 40201 ■ Toll-free: 1-800-814-2028 ■ Local: 502-778-2791 ■ Quote & Order Fax: 1-800-444-0602
F-32051 (03/10)
NOTE: In line w ith its p olicy to continually imp rove its products, Vulcan rese rves the right to change materi als and s pecicatio ns without noti ce.
301⁄
775
301⁄
775
303⁄
772
2
2
8
Loading...