The operating information on this equipment has been prepared for use by qualified and/or authorized operating
personnel.
All installation and service on this equipment is to be performed by qualified, certified, licensed and/ or
authorized installation or service personnel, with the exception of any part marked with a D in front of the part
number.
To obtain the name and location of an authorized Vulcan service agency, contact your Food Service Equipment
dealer by calling 1-800-626-2700.
DEFINITIONS
QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL
Qualified or authorized operating personnel are those who have carefully read the information in this manual
and are familiar with the equipment's functions or have had previous experience with the operation of the
equipment covered in this manual.
1. For the installation of gas piping from the outlet side of the gas meter, or the service regulator when the meter
is not provided, and the connection and installation of the gas appliance, qualified installation personnel must
be experienced in such work, be familiar with all precautions required, and have complied with all
requirements of state or local authorities having jurisdiction. In the absence of local codes, installation must
comply with National Fuel Gas Code ANSI Z223.1 -latest edition.
2. For the installation of electrical wiring from the electric meter, main control box or service outlet to the electric
appliance, qualified installation personnel must be experienced in such work, be familiar with all precautions
required, and have complied with all requirements of state or local authorities having jurisdiction. In the
absence of local codes, installation must comply with the National Electrical Code ANSI NFPA No. 70 latest
edition.
3. For the installation of steam piping from the source of supply to the service inlet of the appliance, qualified
installation personnel must be experienced in such work, be familiar with all precautions required, and have
complied with all requirements of state or local authorities having jurisdiction.
QUALIFIED SERVICE PERSONNEL
Qualified service personnel are those who are familiar with this equipment who have been endorsed by our
company. All authorized service personnel are required to be equipped with a complete set of service and parts
manuals and stock a minimum amount of parts for this equipment.
SHIPPING DAMAGE CLAIM PROCEDURE
For your protection, please note that equipment in this shipment was carefully inspected and packed by skilled
personnel before leaving the factory. The transportation company assumes full responsibility for safe delivery
upon acceptance of this shipment.
If shipment arrives damaged:
1. VISIBLE LOSS OR DAMAGE — Be certain this is noted on freight bill or express receipt and signed by
person making delivery.
2. FILE CLAIM FOR DAMAGES IMMEDIATELY — Regardless of extent of damage.
3. CONCEALED LOSS OR DAMAGE — If damage is unnoticed until merchandise is unpacked, notify
transportation company or carrier immediately, and file "concealed damage" claim with them. This must be
done within fifteen (15) days of the date the delivery is made to you. Be sure to retain container for
inspection.
We cannot assume responsibility for damage or loss incurred in transit. We will, however, be glad to furnish you
with necessary documents to support your claim.
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
2
INDEX
DESCRIPTION
PAGE
DEFINITIONS OF PERSONNEL (OPERATING, INSTALLATION and SERVICE) AND SHIPPING
15 16
Your Vulcan floor mounted tilting Braising Pan is produced with quality workmanship and material. Proper
installation, usage and maintenance will result in many
years of satisfactory performance.
The manufacturer suggests that you thoroughly read
DAMAGE CLAIM PROCEDURE
(Inside Front Cover)
INDEX 3
DESCRIPTION 4
INSTALLATION 5
CONTROLS 5
ELECTRICAL CHARACTERISTICS 6
this entire manual and carefully follow all of the instructions provided. Retain this manual for future reference.
A rating plate with the unit model number, serial
number and the electrical supply that the unit requires
is on the lower inside corner of the left console.
OPERATION 7
OPERATING TIPS 7
CLEANING 8
COOKING CHART 9-11
PARTS LIST: GEAR BOX ASSEMBLY AND ELECTRICAL BOX ASSEMBLY 12-13
TYPICAL BRAISING PAN (208V) ELEMENT BLOCK 14
WIRING DIAGRAMS: VETS 24 & 30
VETS 40
3
DESCRIPTION
A. The capacity of this tilting braising pan is indicated
by the last two numbers in the model number; 24
gallons, 30 gallons or 40 gallons.
E. A great deal of heavy lifting and transferring of
foods from one pan to another can be eliminated
and, therefore, pot washing will be reduced.
B. The tilting braising pan is one of the most versatile
pieces of equipment to be found in any restaurant
or institutional kitchen.
C. This unit will stew, simmer, pan fry, braise, grill
and sauté and all with a very uniform heat pattern.
It cannot be used as a deep fat fryer.
D. The tilting braising pan should always be pre-
heated and allowed to cycle, for more satisfactory
results.
F. Frozen vegetables can be cooked in the braising
pan, placed in the serving pan, then removed and
transferred directly to the serving line.
G. The cover has a lip at the back edge which directs
the condensate on the inside of the cover into the
braising pan.
H. The unit tilts easily to 90°. The optional receiving
pan is always approximately 2 inches from the
pouring lip of the braising pan.
4
INSTALLATION
WARNING: Electrical and grounding
connections must comply with
applicable portions of the National
Electrical code and/or other local
electrical codes.
d. A wiring diagram is provided inside the control
housing cover panel.
e. All braising pans have been factory tested for
control operation and for electrical heating elements.
A. SETUP
a. Set the tilting braising pan in place, level and
mark leg anchoring locations.
b. Remove the braising pan, prepare the leg bolt
down locations and return the braising pan to
its prepared location.
c. Level the pan then pull threads up tight to the
counter or stand.
d. Seal the legs with a high grade sealing com
pound.
B. SERVICE CONNECTIONS
a. All internal wiring for the braising pan was
completed at the factory.
b. Have a waterproof electrical connection from
incoming lines to the control box.
c. Ground braising pan to the terminal provided
in the control housing.
f. Connect water to faucet if optional faucet was
purchased.
g. Turn unit on and check for proper operation.
CONTROLS
The controls on the braising pan are an "ON-OFF"
electrical switch and a thermostat. Turn the switch to
"ON" when ready to start cooking. Dial the temperature
control to bring the pan up to temperature, let it cycle
then begin cooking. Do not leave the unit "ON" when
not warming it up for cooking, or when nothing is being
cooked. Turn the unit "OFF" when through cooking.
The pilot light lights when unit is turned on and the
heating elements turn on. Use the thermostat to dial
the correct
temperature for the type of cooking being done. When
the dialed temperature is reached the elements turn
off. The light and heating elements continue to cycle
off and on, holding the dialed temperature.
5