Vulcan Hart VETS SERIES Operation Manual

INSTALLATION, OPERATING,
SERVICE AND PARTS MANUAL FOR
FLOOR MOUNTED TILTING
BRAISING PANS
VETS SERIES
Vulcan service agencies are located throughout the United States. For location and phone number of one near you, call your local Vulcan dealer.
(502) 778-2791 TECHNICAL ASSISTANCE (800) 626-2700
FORM 30008 (2-90)
IMPORTANT
OPERATING, INSTALLING AND SERVICE PERSONNEL
The operating information on this equipment has been prepared for use by qualified and/or authorized operating personnel.
All installation and service on this equipment is to be performed by qualified, certified, licensed and/ or authorized installation or service personnel, with the exception of any part marked with a D in front of the part number.
To obtain the name and location of an authorized Vulcan service agency, contact your Food Service Equipment dealer by calling 1-800-626-2700.
DEFINITIONS
QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL
Qualified or authorized operating personnel are those who have carefully read the information in this manual and are familiar with the equipment's functions or have had previous experience with the operation of the equipment covered in this manual.
1. For the installation of gas piping from the outlet side of the gas meter, or the service regulator when the meter is not provided, and the connection and installation of the gas appliance, qualified installation personnel must be experienced in such work, be familiar with all precautions required, and have complied with all requirements of state or local authorities having jurisdiction. In the absence of local codes, installation must comply with National Fuel Gas Code ANSI Z223.1 -latest edition.
2. For the installation of electrical wiring from the electric meter, main control box or service outlet to the electric appliance, qualified installation personnel must be experienced in such work, be familiar with all precautions required, and have complied with all requirements of state or local authorities having jurisdiction. In the absence of local codes, installation must comply with the National Electrical Code ANSI NFPA No. 70 latest edition.
3. For the installation of steam piping from the source of supply to the service inlet of the appliance, qualified installation personnel must be experienced in such work, be familiar with all precautions required, and have complied with all requirements of state or local authorities having jurisdiction.
QUALIFIED SERVICE PERSONNEL
Qualified service personnel are those who are familiar with this equipment who have been endorsed by our company. All authorized service personnel are required to be equipped with a complete set of service and parts manuals and stock a minimum amount of parts for this equipment.
SHIPPING DAMAGE CLAIM PROCEDURE
For your protection, please note that equipment in this shipment was carefully inspected and packed by skilled personnel before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of this shipment.
If shipment arrives damaged:
1. VISIBLE LOSS OR DAMAGE — Be certain this is noted on freight bill or express receipt and signed by
person making delivery.
2. FILE CLAIM FOR DAMAGES IMMEDIATELY — Regardless of extent of damage.
3. CONCEALED LOSS OR DAMAGE — If damage is unnoticed until merchandise is unpacked, notify
transportation company or carrier immediately, and file "concealed damage" claim with them. This must be done within fifteen (15) days of the date the delivery is made to you. Be sure to retain container for inspection.
We cannot assume responsibility for damage or loss incurred in transit. We will, however, be glad to furnish you with necessary documents to support your claim.
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
2
INDEX
DESCRIPTION
PAGE
DEFINITIONS OF PERSONNEL (OPERATING, INSTALLATION and SERVICE) AND SHIPPING
15 16
Your Vulcan floor mounted tilting Braising Pan is pro­duced with quality workmanship and material. Proper installation, usage and maintenance will result in many years of satisfactory performance.
The manufacturer suggests that you thoroughly read
DAMAGE CLAIM PROCEDURE (Inside Front Cover)
INDEX 3
DESCRIPTION 4
INSTALLATION 5
CONTROLS 5
ELECTRICAL CHARACTERISTICS 6
this entire manual and carefully follow all of the instruc­tions provided. Retain this manual for future reference.
A rating plate with the unit model number, serial number and the electrical supply that the unit requires is on the lower inside corner of the left console.
OPERATION 7
OPERATING TIPS 7
CLEANING 8
COOKING CHART 9-11
PARTS LIST: GEAR BOX ASSEMBLY AND ELECTRICAL BOX ASSEMBLY 12-13
TYPICAL BRAISING PAN (208V) ELEMENT BLOCK 14
WIRING DIAGRAMS: VETS 24 & 30 VETS 40
3
DESCRIPTION
A. The capacity of this tilting braising pan is indicated
by the last two numbers in the model number; 24 gallons, 30 gallons or 40 gallons.
E. A great deal of heavy lifting and transferring of
foods from one pan to another can be eliminated and, therefore, pot washing will be reduced.
B. The tilting braising pan is one of the most versatile
pieces of equipment to be found in any restaurant or institutional kitchen.
C. This unit will stew, simmer, pan fry, braise, grill
and sauté and all with a very uniform heat pattern. It cannot be used as a deep fat fryer.
D. The tilting braising pan should always be pre-
heated and allowed to cycle, for more satisfactory results.
F. Frozen vegetables can be cooked in the braising
pan, placed in the serving pan, then removed and transferred directly to the serving line.
G. The cover has a lip at the back edge which directs
the condensate on the inside of the cover into the braising pan.
H. The unit tilts easily to 90°. The optional receiving
pan is always approximately 2 inches from the pouring lip of the braising pan.
4
INSTALLATION
WARNING: Electrical and grounding connections must comply with applicable portions of the National Electrical code and/or other local electrical codes.
d. A wiring diagram is provided inside the control
housing cover panel.
e. All braising pans have been factory tested for
control operation and for electrical heating ele­ments.
A. SETUP
a. Set the tilting braising pan in place, level and
mark leg anchoring locations.
b. Remove the braising pan, prepare the leg bolt
down locations and return the braising pan to its prepared location.
c. Level the pan then pull threads up tight to the
counter or stand.
d. Seal the legs with a high grade sealing com
pound.
B. SERVICE CONNECTIONS
a. All internal wiring for the braising pan was
completed at the factory.
b. Have a waterproof electrical connection from
incoming lines to the control box.
c. Ground braising pan to the terminal provided
in the control housing.
f. Connect water to faucet if optional faucet was
purchased.
g. Turn unit on and check for proper operation.
CONTROLS
The controls on the braising pan are an "ON-OFF" electrical switch and a thermostat. Turn the switch to "ON" when ready to start cooking. Dial the temperature control to bring the pan up to temperature, let it cycle then begin cooking. Do not leave the unit "ON" when not warming it up for cooking, or when nothing is being cooked. Turn the unit "OFF" when through cooking. The pilot light lights when unit is turned on and the heating elements turn on. Use the thermostat to dial the correct