For additional information on Vulcan-Hart or to locate an authorized parts
and service provider in your area, visit our website at www.vulcanequipment.com
VULCAN-HART
DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC
WWW.VULCANEQUIPMENT.COM
3600 NORTH POINT BLVD.
BALTIMORE, MD 21222
FORM F-37496 ( 05-10 )
Page 2
C24EO SERIES STEAMER
IMPORTANT FOR YOUR SAFETY
THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO
INSTALL THIS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD
START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY
THIS MANUAL.
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN CAUSE PROPERTY
DAMAGE, INJURY OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE INSTRUCTIONS
THOROUGHLY BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.
SERVICE AND PARTS INFORMATION ...................................................................................... 23
— 4 —
Page 5
C24EO SERIES STEAMER
INSTALLATION, OPERATION AND CARE OF
MODEL C24EO SERIES STEAMERS
PLEASE KEEP THIS MANUAL FOR FUTURE USE
GENERAL
Vulcan convection steamers are produced
with quality workmanship and material. Proper
installation, usage and maintenance will result
in many years of satisfactory performance. It
is suggested that you thoroughly read this
entire manual and carefully follow all of the
instructions provided.
The C24EO3 Steamer is rated at 8.0 kW and
the C24EO5 Steamer is rated at 12.0 kW.
Model C24EO3 can accommodate three 2
deep (6.4 cm) steam pans. Model C24EO5
can accommodate five 2
steam pans. The C24EO3 and C24EO5
electric convection steamers are designed
for cooking vegetables, eggs, and other foods,
in commercial kitchens. The steamer has a
0 to 60 minute timer. The steamers are
designed for installation on countertops or on
optional stands.
1
/2" deep (6.4 cm)
1
/2"
INSTALLATION
UNPACKING
This steamer was inspected before leaving
the factory. The transportation company
assumes full responsibility for safe delivery
upon acceptance of the shipment. Immediately
after unpacking, check for possible shipping
damage. If the steamer is found to be
damaged, save the packaging material and
contact the carrier within 15 days of delivery.
INSTALLATION CODES
AND STANDARDS
The steamer must be installed in accordance
with:
In the United States of America:
1. State and local codes.
2. National Electrical Code, ANSI/NFPA-70
(latest edition). Copies may be obtained
from The National Fire Protection
Association, Batterymarch Park, Quincy,
MA 02269.
Before installing, verify that the electrical supply
agrees with the specifications on the data plate
located on the front of the steamer in the lower
right hand corner. If the supply and equipment
requirements do not agree, do not proceed with
the installation. Contact your dealer or VulcanHart immediately.
The C24EO3 is shipped pre-wired for 208 V,
50 to 60 Hz, 3-phase. 240 V and single phase
operation require changes to the heater
connection 240 V, 50 to 60 Hz, 3-phase / 240 V,
50 to 60 Hz, 1-phase and 208 V, 50 to 60 Hz,
1-phase.
The C24EO5 is voltage specific. It is
available at 208 V, 50 to 60 Hz, 3-phase /
240 V, 50 to 60 Hz, 3-phase or 480 V, 50 to
60 Hz, 3-phase. It can be field converted to
single phase.
3. Vapor Removal from Cooking Equipment,
(NFPA-96, latest edition) available from NFPA.
In Canada:
1. Local codes.
2. Canadian Electric Code, CSA C22.2 (latest
edition). Copies may be obtained from
The Canadian Standard Association, 5060
Spectrum Way, Suite 100, Mississauga,
Ontario, Canada L4W 5N6.
LOCATION
The installation location must allow adequate
clearances for servicing and proper operation.
Minimum clearance for proper air circulation
is 2" (5.1 cm) on the sides and 6" (15.2 cm) on
the back.
— 5 —
Page 6
C24EO SERIES STEAMER
LEVELING FEET
This steamer is shipped with four 2" leveling
feet. Optional 4" leveling feet are available.
The 2" feet can be removed and the optional 4"
feet can be threaded into holes on the bottom
of the unit.
LEVELING
Position and level the unit using leveling feet.
Front of unit should be
the rear as indicated in Figure 1. Unit should
be level side to side.
Level the steamer front to back and side to
side by turning the adjustable feet.
1
/16" to 1/8" higher than
ANCHORING STEAMER
1. Place steamer in the desired location on
the countertop and mark four corners.
Remove the steamer and drill
indicated in Figure 2.
2. Apply a bead of RTV or other NSF approved
sealant around the bottom edge of the
steamer. If anchoring the steamer, this
bottom seal is necessary to meet NSF
requirements.
3. Set steamer on countertop and bolt down
securely with
3
/8" by 16" bolts (not supplied).
Screw length should be tabletop thickness
1
plus
/2" for proper thread engagement.
1
/2" holes as
Figure 1: Leveling Steamer
Figure 2: Anchoring Steamer
OPTIONAL ACCESSORIES
Optional accessories such as stands and
stacking kit will include directions for
assembly.
— 6 —
Page 7
ELECTRICAL CONNECTIONS
: Electrical and
grounding connections must comply
with the applicable portions of the
National Electrical Code and/or other
local electrical codes.
When making electrical connections, use copper
wire suitable for at least 200°F (90°C). The
steamer must be grounded. The wiring diagram
is located on the inside of the right panel.
Steamers are wired for 3-phase and can be
converted to 1-phase by relocating the jumper
wires on the terminal block as shown on the
wiring diagram.
C24EO SERIES STEAMER
— 7 —
Page 8
C24EO SERIES STEAMER
ELECTRICAL DATA
ModelVoltsKWAmp @Amp @
1 PH3 PH
C24EO3208838.522.2
240833.319.2
C24EO52081257.733.3
2401250.028.9
48012N/A14.4
SERVICE CONNECTIONS
Water Connections
No water supply connections are required, as
the steamer is filled manually.
Water Treatment
equipment life. Water conditions vary from
one location to another. Ask your municipal
water supplier for details about your local
water supply prior to installation. Presence of
sediment, silica, excess chlorides or other
dissolved solids may lead to a
recommendation for alternate form(s) of water
treatment. Test the water with the test strip
included with the steamer. Other factors
affecting steam generation are iron content,
amount of chloridation and dissolved gases.
Drain Connection
The C24EO can be configured to drain through
either the rear panel or through the bottom
base plate.
The unit is configured to be drained through
the rear panel from the factory. The unit is
supplied with a 12" length of
5
/8" ID hose. If this
length is insufficient, remove the hose and
install a new hose ordered to the desired
length. The factory
5
/8" ID silicone hose part
number is 557475. Hose is sold by the foot.
A local water treatment specialist should be
consulted before installation of steam
generating equipment.
Hardness*No more than 3 grains
Silicaless than 13 ppm
Total Chlorineless than 4.0 ppm
PHrange 6.5 to 8
Undissolved Solids less than 5 microns
*17.1 ppm = 1 grain of hardness
If the water supply fails to meet these
standards, it will be necessary to install a
water conditioner. The use of strainers or
filters will not remove minerals from the water.
Water Requirements
Proper water quality can improve the taste of
the food prepared in the steamer, reduce
liming in the steam generator and extend
See Figure 3.
Figure 3: Rear Panel Drain Connection
(Viewed with right side panel removed)
To field configure the drain through the bottom
base plate, the 4" leg kit (part number 843889)
is required. Also required are a
1
/2" NPT close
pipe nipple (11/8" long) and a 1/2" NPT 90°
elbow, which are available through local home
improvement or plumbing supply houses.
1. Remove right side panel.
2. Remove hose barb from drain.
3. Remove knockout from base plate.
— 8 —
Page 9
C24EO SERIES STEAMER
4. Install the 1/2" NPT close nipple (11/8" long)
into drain.
1
5. Install
/2" NPT 90° elbow onto pipe nipple.
6. Re-use hose barb.
7. Install hose barb into elbow with clamp,
cut to desired length or route to drain.
Figure 4: Bottom Panel Drain Connection
(Viewed with right side panel removed)
INSTALLATION STARTUP
PROCEDURE
: The steamer and its
parts are hot. Use care when operating,
cleaning or servicing the steamer. The
cooking compartment contains live
steam and hot water. Stay clear when
opening the door.
Once the steamer is installed, thoroughly test
the steamer before operation.
1. Check that the proper electrical
connections have been made.
2. Close the drain valve by pushing the
Drain Handle in, located in the lower
right hand corner. Open the door and
pour water into the cooking compartment
up to the water level mark (the water
level mark is visible on the back wall of
the steamer). Do not overfill.
NOTICE Do not connect steamer drain
solidly to any drain piping. The steamer drain
must vent to the atmosphere to avoid creating
a back pressure and possible back siphoning
into the compartment.
VENT HOOD
Local codes may require the steamer to be
located under an exhaust hood. Information
on the construction and installation of
ventilating hoods may be obtained from VaporRemoval from Cooking Equipment, NFPA
Standard No. 96 (latest edition).
BEFORE FIRST USE
Thoroughly clean the steamer before using
for the first time. See the CLEANING section
in this manual.
Figure 5: Water Level Mark
3. Rotate the Timer to CONTINUOUS position.
Fully depress the Power Switch to the
ON
position. The Power Switch will turn
amber, indicating the unit is turned on.
4. With the door open, press in on the door
switch (small rod), located above the door
latch. The COOK light will come on.
Release the door switch and the COOK
light will turn off.
— 9 —
Page 10
C24EO SERIES STEAMER
5. Close the compartment door and wait
approximately 10 minutes for unit to preheat.
6. Rotate the Timer to 5 minutes. The Timer
will not start counting down until the cavity
has reached preheat temperature.
7. When the timer returns to 0, a buzzer will
sound signaling the end of the cooking
cycle. To silence the buzzer, turn the
Timer dial to the OFF position.
8. To turn the steamer off:
a. Depress the Power Switch to
the OFF
b. Allow the steamer
position.
to cool.
c. Open the drain valve and drain the
water from the steamer.
d. Open the compartment door to allow
the inside to dry out.
CALIBRATION PROCEDURE
The right hand side panel must be removed to
access the temperature controller. To achieve
optimum steamer operation, rotate the
Temperature Control to the temperature that
corresponds to the elevation that it is located at.
ELEVATIONDIGITAL
(FT)THERMOMETER - °F (C)
Sea Level210 (99)
1,000208 (98)
2,000206 (97)
3,000204 (96)
4,000202 (94)
6,000198 (93)
7,000196 (91)
8,000195 (90)
9,000 or above194 (90)
1. Remove right side panel.
2. Place a temperature probe approximately
one inch down in the center of steam vent
pipe.
3. Turn steamer on by selecting
CONTINUOUS mode.
4. Using the table above, find the
corresponding temperature for the
elevation and set the Temperature Control.
NOTE: The steamer is preset at the factory to
sea level.
A handheld digital thermometer and
thermocouple are required.
NOTE: If temperature setting is too high, the
boiling action will be excessive and
cause water droplets to exit the steam
vent pipe resulting in high water usage.
Figure 6: Temperature Control
— 10 —
Page 11
C24EO SERIES STEAMER
NOTE: Temperature Control is configured by
vendor to Fahrenheit and cannot be
changed to Celsius. The display
indicates set point temperature only.
a. Wait 3 seconds after releasing the
knob for the selection to be saved in
memory. Display will blink momentarily
to indicate temperature is saved.
b. Allow temperature to stabilize by
completing two heating cycles with
door closed.
NOTE: Temperature display on control is for
reference only. When calibrating, use
the recorded temperature from meter.
5. Record temperature reading from meter
when load light goes out.
6. Compare recorded temperature to the
temperature from table.
a. If recorded temperature is correct, no
adjustment is necessary.
b. If recorded temperature is not correct,
adjust temperature setting and recheck the temperature reading with
meter.
NOTE: If unit cannot be calibrated call your
Authorized Vulcan Servicer.
7. If correct temperature reading is not
attained after 3 attempts, call your
Authorized Vulcan Servicer.
— 11 —
Page 12
C24EO SERIES STEAMER
OPERATION
CONTROLS
: The steamer and its
parts are hot. Use care when operating,
cleaning or servicing the steamer. The
cooking compartment contains live
steam and hot water. Stay clear when
opening the door.
OPERATING THE STEAMER
1. Push the the drain lever in to close the
drain valve.
2. Open the door and pour water into the
cooking compartment up to the water level
mark. The water level mark is visible on
the back wall of the steamer. Unit capacity
is 3 gallons. Do not overfill.
3. Close door.
4. Verify Timer is in the OFF position.
5. Fully depress Power Switch to ON
position. Power light in switch will illuminate
amber.
6. Set timer to 5 minutes. In approximately
15 minutes unit will be preheated and
ready to cook.
7. Set timer to desired time (0 to 60 minutes)
or to CONTINUOUS position.
8. At the end of the timed cycle an audible
alarm will sound.
Figure 7: Controls
Power Switch/Low Water Reset: Turns
unit OFF/ON/RESETS LOW WATER LIGHT/
ALARM.
Low Water Light: When lit, indicates
additional water is required.
Timer: Selects the desired cooking time or
the CONTINUOUS position.
COOK Light: When lit, indicates the timer is
set and door is closed.
9. The unit returns to the idle temperature.
NOTE: Timer will not function until preheat
has been completed.
LOW WATER
1. When the Low Water light is illuminated
the unit needs to be refilled with water. An
audible alarm will sound.
2. Fully depress Power Switch to OFF
position.
4. Refill unit with water.
5. Close door.
6. Fully depress Power Switch to ON
position to cancel Low Water alarm.
7. Timer will resume when steamer reaches
cooking temperature.
NOTE: Refill the unit when not in use or during
slow times to avoid running out of water.
Running out of water during a cooking
cycle will lengthen cook time.
— 12 —
Page 13
C24EO SERIES STEAMER
SHUTDOWN
1. Rotate Timer to OFF position.
2. Fully depress Power Switch to OFF
position.
3. Allow steamer to cool.
4. Open the drain valve and drain the water
from steamer.
5. Open the compartment door to allow the
inside to dry.
6. Follow cleaning instructions in this manual.
EXTENDED SHUTDOWN
1. Fully depress Power Switch to OFF
position.
2. Clean the interior and exterior of unit.
3. Leave door open.
4. Disconnect power.
— 13 —
Page 14
C24EO SERIES STEAMER
CLEANING
COOKING COMPARTMENT DRAIN
Remove any particles or debris that may be
blocking the drain. Make a solution of warm
water with non-chloride detergent and pour
1
/2 gallon (1.9 liters) of it down the compartment
drain. Rinse by pouring
1
/2 gallon (1.9 liters) of
hot water down the compartment drain.
Figure 8: Oven Cavity
COMPARTMENT
The compartment, pan guides, and baffle
should be cleaned daily. The exterior should
be cleaned daily.
Thoroughly clean the exposed surfaces (sides,
front, door and top) with a damp cloth and polish
with a clean cloth daily. To remove discolorations,
use a nonabrasive cleaner.
DOOR GASKET
Clean the gasket sealing surface of the
compartment door daily to remove food acids
for maximum gasket life. Do not use any
solvents or sharp instruments. Wash with a
cloth moistened in a solution of mild detergent
and warm water. Rinse with a fresh cloth
moistened with warm water to remove all
traces of detergent.
Wipe dry with a clean cloth. Never apply food
oils or petroleum lubricants directly to the
door gasket. Petroleum-based solvents and
lubricants will reduce gasket life.
LEAVE COMPARTMENT DOOR OPEN
Leave the compartment door slightly open
when the steamer is not in use. When the
compartment is idle, never latch the door and
apply pressure to the door gasket. Leaving the
gasket under pressure can cause permanent
deformation and reduce gasket life.
Remove the pan guides by lifting up and out.
Wash with a solution of warm water with nonchloride detergent. Rinse with warm water.
Remove the baffle from the compartment by
lifting up and out. Wash with a solution of
warm water with non-chloride detergent. Rinse
with warm water.
NOTE: Failure to reinstall baffle after cleaning
will affect cooking performance.
Wash the inside of the compartment with a
solution of warm water with non-chloride
detergent. Rinse with warm water.
Figure 9: Leave Door Open
— 14 —
Page 15
C24EO SERIES STEAMER
STAINLESS STEEL EQUIPMENT
CARE AND CLEANING
Contrary to popular belief, stainless steels
ARE susceptible to rusting.
Corrosion on metals is everywhere. It is
recognized quickly on iron and steel as unsightly
yellow/orange rust. Such metals are called
“active” because they actively corrode in a natural
environment when their atoms combine with
oxygen to form rust.
Stainless steels are passive metals because
they contain other metals, like chromium,
nickel and manganese, that stabilize the
atoms. 400 series stainless steels are called
ferritic, contain chromium, and are magnetic;
300 series stainless steels are called
austenitic, containing chromium and nickel;
and 200 series stainless, also austenitic,
contains manganese, nitrogen and carbon.
Austenitic types of stainless are not magnetic,
and generally provide greater resistance to
corrosion than ferritic types.
With 12 to 30% chromium, an invisible passive
film covers the steel’s surface acting as a shield
against corrosion. As long as the film is intact
and not broken or contaminated, the metal is
passive and stainless. If the passive film of
stainless steel has been broken, equipment
starts to corrode and starts to rust.
Enemies of Stainless Steel
There are three basic things which can break
down stainless steel’s passivity layer and
allow corrosion to occur.
1. Mechanical abrasion.
Water comes out of the faucet in varying
degrees of hardness. Depending on what
part of the country you live in, you may have
hard or soft water. Hard water may leave
spots, and when heated leaves deposits
behind that if left to sit, will break down the
passive layer and rust stainless steel. Other
deposits from food preparation and service
must be properly removed.
Chlorides are found nearly everywhere. They
are in water, food and table salt. One of the
worst chloride perpetrators can come from
household and industrial cleaners.
So what does all this mean?
Don’t despair!
Here are a few steps that can help prevent
stainless steel rust.
1. Use the proper tools.
When cleaning stainless steel products,
use non-abrasive tools. Soft cloths and
plastic scouring pads will not harm steel’s
passive layer. Stainless steel pads also
can be used but the scrubbing motion
must be in the direction of the
manufacturers’ polishing marks.
2. Clean with the polish lines.
Some stainless steel comes with visible
polishing lines or grain. When visible lines
are present, always scrub in a motion
parallel to the lines. When the grain cannot
be seen, play it safe and use a soft cloth or
plastic scouring pad.
3. Use alkaline, alkaline chlorinated or
non-chloride containing cleaners.
2. Deposits and water.
3. Chlorides.
Mechanical abrasion means those things that
will scratch a steel surface. Steel pads, wire
brushes and scrapers are prime examples.
While many traditional cleaners are loaded
with chlorides, the industry is providing an
ever-increasing choice of non-chloride
cleaners. If you are not sure of chloride
content in the cleaner used, contact your
cleaning supplier. If your present cleaner
contains chlorides, ask your supplier if
they have an alternative. Avoid cleaners
containing quaternary salts; it also can
attack stainless steel and cause pitting
and rusting.
— 15 —
Page 16
C24EO SERIES STEAMER
4. Treat your water.
Though this is not always practical,
softening hard water can do much to
reduce deposits. There are certain filters
that can be installed to remove distasteful
and corrosive elements. To insure proper
water treatment, call a treatment specialist.
5. Keep your food equipment clean.
Use alkaline, alkaline chlorinated or nonchloride cleaners at recommended
strength. Clean frequently to avoid buildup of hard stubborn stains. If you boil water
in stainless steel equipment, remember
the single most likely cause of damage is
chlorides in the water. Heating cleaners
that contain chlorides have a similar effect.
6. Rinse, rinse, rinse.
If chlorinated cleaners are used, rinse and
wipe equipment and supplies dry
immediately. The sooner you wipe off
standing water, especially when it contains
cleaning agents, the better. After wiping
equipment down, allow it to air dry; oxygen
helps maintain the stainless steel’s
passivity film.
7. Never use hydrochloric acid (muriatic
acid) on stainless steel.
8. Regularly restore/passivate stainless
steel.
Recommended cleaners for specific
situations
Cleaning
Job
Routine
cleaning
Fingerprints
& smears
Stubborn
stains &
discoloration
Grease &
fatty acids,
blood, burnton-foods
Grease & oil
Restoration/
Passivation
Agent
Soap,
ammonia,
detergent,
Medallion
Arcal 20, LacO-Nu Ecoshine
Cameo, Talc,
Zud, First
Impression
Easy-off, DeGrease It Oven
Aid
Any good
commercial
detergent
Benefit, Super
Sheen
Comments
Apply with cloth
or sponge
Provides barrier
film
Rub in direction
of polish lines
Excellent
removal on all
finishes
Apply with
sponge or cloth
Review
1. Stainless steels rust when passivity (film-shield) breaks down as a result of scrapes,
scratches, deposits and chlorides.
2Stainless steel rust starts with pits and cracks.
3. Use the proper tools. Do not use steel pads, wire brushes or scrapers to clean stainless steel.
4. Use non-chlorinated cleaners at recommended concentrations. Use only chloride-free cleaners.
5. Soften your water. Use filters and softeners whenever possible.
6. Wipe off cleaning agent(s) and standing water as soon as possible. Prolonged contact causes
eventual problems.
To learn more about chloride-stress corrosion and how to prevent it, contact the equipment
manufacturer or cleaning material supplier.
Developed by Packer Engineering, Naperville, Ill., an independent testing laboratory.
— 16 —
Page 17
MAINTENANCE
C24EO SERIES STEAMER
: The steamer and its
parts are hot. Use care when operating,
cleaning or servicing the steamer. The
cooking compartment contains live
steam and hot water. Stay clear when
opening the door.
Steamer must be cleaned daily. See
CLEANING section.
REMOVAL OF LIME SCALE DEPOSITS
: Read and follow the
instructions on the deliming material
package. Avoid contact with skin and
eyes. Wear plastic or rubber gloves
and safety goggles when handling.
Wash thoroughly after handling. If
deliming solution comes in contact
with the skin or eyes, rinse thoroughly
with clean water.
: The steamer and its
parts are hot. Use care when operating,
cleaning or servicing the steamer. The
cooking compartment contains live
steam and hot water. Stay clear when
opening the door.
The steamer should be delimed when scale is
present in the cavity well. Deliming may be
required frequently depending on water quality
and scale build up. This is in accordance with
the minimum preventive maintenance
schedule required by warranty.
2. Plastic or rubber gloves.
3. Safety goggles or face shield.
4. Spray bottle.
5. 1-gallon container for mixing the deliming
solution.
NOTE: Deliming solution may cause the
surface of aluminum measuring tools
to tarnish or etch.
Procedure:
1. Turn steamer off. Drain the steamer.
2. One bag will treat a C24EO3 or C24EO5
steamer.
•1 bag to 2 gallons warm water
3. Spray cavity walls with solution. Pour
solution into cavity well.
•Maximum steamer capacity 3 gallons
4. Fully depress Power Switch to ON
position and set Timer for 5 min. After
timer sounds, rotate Timer dial to OFF
position and fully depress Power Switch
to OFF
5. Let delime solution soak for a minimum of
30 minutes, maximum 60 minutes. If scale
is still present, repeat steps 1 through 5.
6. Drain the steamer and rinse thoroughly
with warm clean water.
7. Dry with a clean dry cloth.
8. Leave steamer door open when not in use.
position.
Items required (not provided):
1. Deliming Solution – Scale Release™
Part Number 854893-13 (qty. 1).
•Contact the local Authorized Vulcan
Servicer or refer to website
www.vulcanequipment.com
DOOR GASKET
If the door gasket is leaking due to a nick or
cut, it must be replaced. Damage to the gasket
sealing surface will cause steam leakage.
— 17 —
Page 18
C24EO SERIES STEAMER
COOKING HINTS
The steamer efficiently cooks vegetables and
other foods for immediate serving. Steam
cooking should be carefully time controlled.
Keep hot food holding-time to a minimum to
produce the most appetizing results. Prepare
small batches. Cook only enough to start serving,
then cook additional amounts to meet demand.
ACCEPTABLE PAN SIZES
The steamer accommodates combinations
of full, half and one-third size pans, solid or
perforated.
ModelNumber of Pans Accommodated
Depth of Pan
1"21/2"4" 6"
C24EO36321
PREPARATION
Prepare vegetables, fruits, meats, seafood and
poultry normally by cleaning, separating, cutting,
removing stems, etc. Cook root vegetables in a
perforated pan. Other vegetables may be cooked
in a perforated pan unless juices are being
saved. Liquids can be collected in a solid 12" x
20" pan placed under a perforated pan.
Perforated pans are used for frankfurters,
wieners and similar items when juices do not
need to be preserved. Solid pans are good for
cooking puddings, rice, and hot breakfast
cereals. Vegetables and fruits are cooked in
solid pans in their own juice. Meats and poultry
are cooked in solid pans to preserve their juice
or retain broth.
Canned foods can be heated in their opened
cans (cans placed in 12" x 20" solid pans) or
the contents may be poured into solid pans.
DO NOT place unopened cans in the steamer.
C24EO510532
COOKING GUIDELINES
The steamer cooks vegetables, frankfurters,
eggs in their shells, and certain other meats or
food items at atmospheric pressure.
These cooking guidelines are suggestions only.
You should experiment with your food products
to determine the cooking times that will give you
the best results. Variables which affect cooking
time include size, weight, thickness of foods,
temperature, density, previous condition of the
foods (fresh, pre-blanched or frozen) and degree
of doneness desired.
Frozen Food Items
Separate frozen foods into smaller pieces to
allow more efficient cooking.
Use a pan cover for precooked frozen dishes
that cannot be cooked in the covered
containers in which they are packed if they
require more than 15 minutes of cooking time.
When a cover is used, approximately onethird additional cooking time is necessary.
Cooking time for frozen foods depends on
the amount of defrosting required. If time
permits, allow frozen foods to partially thaw
overnight in a refrigerator. This will reduce
their cooking time.
— 18 —
Page 19
C24EO SERIES STEAMER
PRODUCTS TO BE COOKED IN SOLID PANS
PRODUCTTIME (MINUTES)WEIGHT PER PAN
Eggs, Scrambled9 to 128 doz.
Rice, Long Grain (Cover with 4 cups water/lb.)23 to 252 lbs.
Pasta (Place perforated pan inside solid pan,
cover with cold water)
Spaghetti – Regular/Vermicelli10 to 15
Macaroni - Shells/Elbows13 to 18
Noodles - 1/2" Wide10 to 15
Lasagna Noodles13 to 18
Frozen Casseroles, Lasagna33 to 35Full Pan
Meat Loaf, 3-5 Lb. Each38 to 4015 lbs.
Beef
Ground Chuck19 to 2510 lbs.
Sliced as Purchased33 to 4010 lbs.
Shrimp, Frozen, 10 Shrimp per Lb.4 to 54 lbs.
Beans
Baked8 to 910 lb. Can
Refried8 to 910 lb. Can
Canned Vegetables5 to 610 lb. Can
Prunes, Dried11 to 15
— 19 —
Page 20
C24EO SERIES STEAMER
PRODUCTS TO BE COOKED IN PERFORATED PANS
PRODUCTTIME (MINUTES)WEIGHT PER PAN
SEAFOOD
Clams
Frozen9 to 123 doz.
Fresh, Cherrystone4 to 63 doz.
King Crab, Frozen
1
Claws3 to 42
Legs3 to 64
Lobster Tail, Frozen5 to 610 lbs.
Lobster, Live, 10" - 12"4 to 54 Per Pan
Salmon Fillets, Frozen, 8 ounce each4 to 571/2 lbs.
Scallops, Fresh3 to 43 lbs.
Scrod Fillets, Fresh3 to 54 lbs.
/2 lbs.
1
/2 lbs.
EGGS
Hard Cooked14 to 154 doz.
Soft Cooked8 to 104 doz.
Soft Yoke for Caesar Salad5 to 84 doz.
MEATS
Chicken — Breasts, Legs, Thighs19 to 2015 lbs.
Turkey, Frozen
Breasts (2)86 to 906 to 7 lbs. Each
Cut Lengthwise53 to 5520 to 25 lbs.
Corned Beef40 to 756 to 8 lbs.
Hot Dogs and Wieners2 to 380 to 100 Count
VEGETABLES
Asparagus Spears
Frozen10 to 123 lbs.
Fresh4 to 55 lbs.
Beans
Green 2" Cut, Frozen/Fresh5 to 65 lbs.
Lima, Frozen7 to 85 lbs.
Baby Lima, Frozen4 to 55 lbs.
Brussel Sprouts, Frozen5 to 65 lbs.
— 20 —
Page 21
C24EO SERIES STEAMER
PRODUCTTIME (MINUTES)WEIGHT PER PAN
VEGETABLES (Cont’d.)
Broccoli
Spears, Frozen6 to 84 lbs.
Spears, Fresh4 to 65 lbs.
Flowerettes, Frozen4 to 65 lbs.
Cabbage, Fresh, 1/6 Cut6 to 85 lbs.
Carrots
Baby Whole, Frozen6 to 87 lbs.
Crinkle Cut, Frozen7 to 84 lbs.
Sliced, Fresh9 to 119 lbs.
Cauliflower, Flowerettes
Frozen4 to 64 lbs.
Fresh7 to 85 lbs.
Celery, 1" Diagonal Cut5 to 75 lbs.
Corn
Yellow Whole Kernel, Frozen3 to 55 lbs.
Cobbettes, Frozen6 to 827 Ears
Corn-On-Cob, Fresh16 to 1880 Ears
16 to 1854 Ears
10 to 1218 Ears
Peas, Green4 to 65 lbs.
Potatoes, Whole Russet50 to 5540 lbs.
Spinach
Chopped, Frozen15 to 176 lbs.
Defrosted4 to 56 lbs.
Fresh Cut2 to 32 lbs.
Squash, Acorn Halves22 to 2510 Halves
Zucchini, Slices6 to 810 lbs.
Frozen Mixed Vegetables6 to 75 lbs.
FRUIT
Fruit, Blanch for Peeling
Grapefruit, Oranges2 to 3
Pineapple, Whole for Cutting2 to 4
— 21 —
Page 22
C24EO SERIES STEAMER
TROUBLESHOOTING
SYMPTOMS
Steamer not steaming
Steamer not
steaming properly
Door leaks
POSSIBLE CAUSES
No main power source.
Door is open.
Power switch in OFF position.
Timer is off.
Needs water.
Excessive scale buildup in the
cavity well.
Not connected to correct voltage.
Damaged door gasket.
Damage to gasket sealing surface.
REMEDY
Check the power source.
Close door.
Set power switch to ON.
Set Timer.
Add water.
Descale the steamer (see
REMOVAL OF LIME SCALE
DEPOSITS).
If voltage is not correct, contact
your Authorized Vulcan Servicer.
Check door gasket for damage.
If adjustment is needed, contact
your Authorized Vulcan Servicer.
Water does not drain
properly
Water foaming
Blocked or obstructed steam vent.
Unit not level.
Drain clogged.
Cooking seafood without catch
pan.
Clear steam vent.
See leveling instructions in the
installation section of this
manual.
Unclog drain.
Use a catch pan. Drain and
replace water.
— 22 —
Page 23
C24EO SERIES STEAMER
SERVICE AND PARTS INFORMATION
To obtain service and parts information concerning this model, contact the Authorized Vulcan
Servicer in your area. Refer to our website, www.vulcanequipment.com for a complete listing of
Authorized Service and Parts depots.
When calling for service, the following information (located on your machine data plate) must be
available:
Model Number
Serial Number
Manufacture Date (MD)
Voltage
— 23 —
Page 24
C24EO SERIES STEAMER
(05-10)
— 24 —
PRINTED IN U.S.A.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.