C24EO SERIES STEAMER
IMPORTANT FOR YOUR SAFETY
THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO
INSTALL THIS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD
START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY
THIS MANUAL.
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN CAUSE PROPERTY
DAMAGE, INJURY OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE INSTRUCTIONS
THOROUGHLY BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.
SERVICE AND PARTS INFORMATION ...................................................................................... 23
— 4 —
C24EO SERIES STEAMER
INSTALLATION, OPERATION AND CARE OF
MODEL C24EO SERIES STEAMERS
PLEASE KEEP THIS MANUAL FOR FUTURE USE
GENERAL
Vulcan convection steamers are produced
with quality workmanship and material. Proper
installation, usage and maintenance will result
in many years of satisfactory performance. It
is suggested that you thoroughly read this
entire manual and carefully follow all of the
instructions provided.
The C24EO3 Steamer is rated at 8.0 kW and
the C24EO5 Steamer is rated at 12.0 kW.
Model C24EO3 can accommodate three 2
deep (6.4 cm) steam pans. Model C24EO5
can accommodate five 2
steam pans. The C24EO3 and C24EO5
electric convection steamers are designed
for cooking vegetables, eggs, and other foods,
in commercial kitchens. The steamer has a
0 to 60 minute timer. The steamers are
designed for installation on countertops or on
optional stands.
1
/2" deep (6.4 cm)
1
/2"
INSTALLATION
UNPACKING
This steamer was inspected before leaving
the factory. The transportation company
assumes full responsibility for safe delivery
upon acceptance of the shipment. Immediately
after unpacking, check for possible shipping
damage. If the steamer is found to be
damaged, save the packaging material and
contact the carrier within 15 days of delivery.
INSTALLATION CODES
AND STANDARDS
The steamer must be installed in accordance
with:
In the United States of America:
1. State and local codes.
2. National Electrical Code, ANSI/NFPA-70
(latest edition). Copies may be obtained
from The National Fire Protection
Association, Batterymarch Park, Quincy,
MA 02269.
Before installing, verify that the electrical supply
agrees with the specifications on the data plate
located on the front of the steamer in the lower
right hand corner. If the supply and equipment
requirements do not agree, do not proceed with
the installation. Contact your dealer or VulcanHart immediately.
The C24EO3 is shipped pre-wired for 208 V,
50 to 60 Hz, 3-phase. 240 V and single phase
operation require changes to the heater
connection 240 V, 50 to 60 Hz, 3-phase / 240 V,
50 to 60 Hz, 1-phase and 208 V, 50 to 60 Hz,
1-phase.
The C24EO5 is voltage specific. It is
available at 208 V, 50 to 60 Hz, 3-phase /
240 V, 50 to 60 Hz, 3-phase or 480 V, 50 to
60 Hz, 3-phase. It can be field converted to
single phase.
3. Vapor Removal from Cooking Equipment,
(NFPA-96, latest edition) available from NFPA.
In Canada:
1. Local codes.
2. Canadian Electric Code, CSA C22.2 (latest
edition). Copies may be obtained from
The Canadian Standard Association, 5060
Spectrum Way, Suite 100, Mississauga,
Ontario, Canada L4W 5N6.
LOCATION
The installation location must allow adequate
clearances for servicing and proper operation.
Minimum clearance for proper air circulation
is 2" (5.1 cm) on the sides and 6" (15.2 cm) on
the back.
— 5 —
C24EO SERIES STEAMER
LEVELING FEET
This steamer is shipped with four 2" leveling
feet. Optional 4" leveling feet are available.
The 2" feet can be removed and the optional 4"
feet can be threaded into holes on the bottom
of the unit.
LEVELING
Position and level the unit using leveling feet.
Front of unit should be
the rear as indicated in Figure 1. Unit should
be level side to side.
Level the steamer front to back and side to
side by turning the adjustable feet.
1
/16" to 1/8" higher than
ANCHORING STEAMER
1. Place steamer in the desired location on
the countertop and mark four corners.
Remove the steamer and drill
indicated in Figure 2.
2. Apply a bead of RTV or other NSF approved
sealant around the bottom edge of the
steamer. If anchoring the steamer, this
bottom seal is necessary to meet NSF
requirements.
3. Set steamer on countertop and bolt down
securely with
3
/8" by 16" bolts (not supplied).
Screw length should be tabletop thickness
1
plus
/2" for proper thread engagement.
1
/2" holes as
Figure 1: Leveling Steamer
Figure 2: Anchoring Steamer
OPTIONAL ACCESSORIES
Optional accessories such as stands and
stacking kit will include directions for
assembly.
— 6 —
ELECTRICAL CONNECTIONS
: Electrical and
grounding connections must comply
with the applicable portions of the
National Electrical Code and/or other
local electrical codes.
When making electrical connections, use copper
wire suitable for at least 200°F (90°C). The
steamer must be grounded. The wiring diagram
is located on the inside of the right panel.
Steamers are wired for 3-phase and can be
converted to 1-phase by relocating the jumper
wires on the terminal block as shown on the
wiring diagram.
C24EO SERIES STEAMER
— 7 —
C24EO SERIES STEAMER
ELECTRICAL DATA
ModelVoltsKWAmp @Amp @
1 PH3 PH
C24EO3208838.522.2
240833.319.2
C24EO52081257.733.3
2401250.028.9
48012N/A14.4
SERVICE CONNECTIONS
Water Connections
No water supply connections are required, as
the steamer is filled manually.
Water Treatment
equipment life. Water conditions vary from
one location to another. Ask your municipal
water supplier for details about your local
water supply prior to installation. Presence of
sediment, silica, excess chlorides or other
dissolved solids may lead to a
recommendation for alternate form(s) of water
treatment. Test the water with the test strip
included with the steamer. Other factors
affecting steam generation are iron content,
amount of chloridation and dissolved gases.
Drain Connection
The C24EO can be configured to drain through
either the rear panel or through the bottom
base plate.
The unit is configured to be drained through
the rear panel from the factory. The unit is
supplied with a 12" length of
5
/8" ID hose. If this
length is insufficient, remove the hose and
install a new hose ordered to the desired
length. The factory
5
/8" ID silicone hose part
number is 557475. Hose is sold by the foot.
A local water treatment specialist should be
consulted before installation of steam
generating equipment.
Hardness*No more than 3 grains
Silicaless than 13 ppm
Total Chlorineless than 4.0 ppm
PHrange 6.5 to 8
Undissolved Solids less than 5 microns
*17.1 ppm = 1 grain of hardness
If the water supply fails to meet these
standards, it will be necessary to install a
water conditioner. The use of strainers or
filters will not remove minerals from the water.
Water Requirements
Proper water quality can improve the taste of
the food prepared in the steamer, reduce
liming in the steam generator and extend
See Figure 3.
Figure 3: Rear Panel Drain Connection
(Viewed with right side panel removed)
To field configure the drain through the bottom
base plate, the 4" leg kit (part number 843889)
is required. Also required are a
1
/2" NPT close
pipe nipple (11/8" long) and a 1/2" NPT 90°
elbow, which are available through local home
improvement or plumbing supply houses.
1. Remove right side panel.
2. Remove hose barb from drain.
3. Remove knockout from base plate.
— 8 —