2
/3 jacketed tilting steam kettle, 40 quart capacity.
Steam jacketed kettle mounted on 28" high base cabinet
with stainless steel frame, front full height door, stainless steel side and aluminized rear panel with 6" adjustable legs with flanged feet for anchoring.
Fully welded hemispheric bottom kettle with type 304 stainless steel jacket and type 316 stainless steel liner. Jacket tested to 50 psi (3.4 kg/cm
Steam control valve on right trunnion leg.
12" single temperature deck mounted faucet.
CSD-1 code compliant boiler.
Electric 24 KW steam boiler.
Requires a 208 or 240 volt, 60 Hz, 3 phase power supply
and a separate 120 volt, 60 Hz, 1 phase control circuit, 3 amp.
Water filter system, SPS620V. Includes second year ex­tended limited water associated parts and labor warranty.
One year limited parts and labor warranty.
2
).
Vulcan-Hart Co.
ISO9001
A2780
MODEL: 1T4024E
One 40 quart 2/3 jacketed tilting steam kettle mounted on a 24"wide electric boiler base, Vulcan-Hart Model No. 1T4024E. Steam jacketed kettle mounted on 28" high base cabinet with stainless steel frame, front full height door, stainless steel side and aluminized rear panel with 6" adjustable legs with flanged feet for anchoring. Fully welded hemispheric bottom kettle with type 304 stainless steel jacket and type 316 stainless steel liner. Jacket tested to 50 psi (3.4 kg/cm
2
). Steam control valve on right trunnion leg. 12" single temperature deck mounted faucet. Requires 208 or 240 volt, 60 Hz, 3 phase power supply and a separate 120 volt, 60 Hz, 1 phase control circuit, 3 amp.
Exterior dimensions: Cabinet: 24"w x 35.4"d x 28"h on 6" adjustable legs. Overall height to the lip of the kettle - 47", to the top of the handle - 59".
U L listed. Classified by U L to NSF Std. #4. Meets ASME code.
OPTIONS
Correction package.
- Cabinet door with hasp (lock by others).
- Security type tamper resistant fasteners.
Tilting kettle strainer.
12" dual temperature faucet.
Single phase on 24 KW boiler.
Stepdown transformer (eliminates 120 volt connection).
480 volts, 60 Hz, 3 phase, includes stepdown transformer.
Mount and interconnect kettle with boiler base at factory.
Includes steam supply piping. Shipped on one skid.
Second year extended limited parts and labor warranty.
ACCESSORIES
Stainless steel back panel.
Lift-off cover.
Contour measuring strip.
Single perforated stainless steel basket.
40 Quart
2
/
3
Jacketed Tilting Kettles On Electric Boiler Base
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
F-32380 (2-06)
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
MODEL 1T4024E
40 QUART 2/3 JACKETED TILTING KETTLE ON ELECTRIC BOILER BASE
WATER QUALITY STATEMENT:
The fact that a water supply is potable is no guarantee that it is suitable for steam generation. Your water supply must be within these general guidelines:
SUPPLY PRESSURE 20 - 60 psig HARDNESS* less than 3 grains SILICA less than 13 ppm TOTAL CHLORIDE less than 4.0 ppm pH RANGE 7-8 UN-DISSOLVED SOLIDS less than 5 microns
* 17.1 ppm = 1 grain of hardness
Other factors affecting steam generation are iron content, amount of chloridation and dissolved gases. Water supplies vary from state to state and from locations within a state. Therefore it is necessary that the local water treatment specialist be consulted before the installation of any steam generating equipment.
AMPS PER LINE
MODEL KW
NO. INPUT 208V 240V 208V 240V 480V 240/415V
1T4024E 24 116 100 67 58 29 34
1 PHASE 3 PHASE 220/380V &
TOP VIEW
SERVICE CONNECTIONS: A Junction box: J.I.C. 6 x 6 x 4 for electrical supply connection for heat. B Electrical Connection for Controls: 120/60/1, 300 watt power
C Drain: Condensate box, compartment and boiler, 11/4" NPT. (Provide
D Cold Water Connections (2):
E Water Supply Connection for Kettle Filler Faucet:1/4" NPT.
3 PHASE-4 WIRE
NOTE:
• Dimensions which locate the above connections have a tolerance of + or -3" (+ or -75 mm).
• Installation of backflow preventers, vacuum breakers and other specific code requirements is the responsibility of the owner and installer. It is the responsibility of the owner and installer to comply with local codes.
• Plastic drains are not recommended due to inherent limited tempera­tures of the plastic. Boiler purge temperatures may exceed 180°F. The installer may be required to provide means to reduce boiler purge water temperature to be that of the condensate temperature of 140°F or less.
• This appliance is manufactured for commercial installation only and is not intended for home use.
supply with grounding wire required.
an open air type drain within 12" of condensate box and for best results at a distance so that steam vapors will not enter the steamer from underneath the control area. Do not connect solidly to any drain connection.)
D1 Treated Cold Water Connection: 1/4" NPT for boiler feed. Inlet
water pressure between 20 and 80 psi. D2 Untreated Cold Water Connection: 1/4" NPT for condensate
box. Inlet water pressure between 20 and 80 psi.
EQUIPMENT CLEARANCE:
Rear: 2" Right: 0" Left: 0"
BRIMFUL CAPACITIES (in 4 oz. servings):
40 quarts / 10 gallons / 37.5 liters - 320 servings.
FRONT VIEW
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and
specifications without notice.
F-32380 (2-06)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
SIDE VIEW
Printed On Recycled Paper