SPECIFICATIONS:
Gas heated convection steamer, Vulcan-Hart Model No. (VSX42GT) (VSX42G5). Two stainless steel cooking compart­ments with coved interior corners. Heavy duty stainless steel "slammable" doors can be opened and closed at anytime during the cooking cycle. Steam shuts off when door(s) are opened. Tilting kettle mounted to left of cooking compartments and inter­connected to steam generator. Deck mount dual temperature faucet with 12" swing spout. Convection steamer mounted on 28" high base cabinet with stainless steel frame, full height doors and side panels with aluminized rear panels with 6" adjustable legs with anged feet for anchoring. 200,000 BTU/hr. steam boiler with electronic ignition. Includes a CSD-1 compliant high pressure limit switch (15 psi), low water cut-off, automatic water ll, automatic generator blow down, 15 psi pressure relief valve and 15 psi kettle connection. Compartment controls include 60 minute dial timer with buzzer, green "ready" and red "cooking" indicator lights. Stainless steel rear ue.
Exterior dimensions: VSX42GT: 42"w x 35.4"d x 603/8"h. VSX42G5: 42"w x 35.4"d x 73"h.
CSA design certied. Classied by U L to NSF Std. #4. Meets ASME code.
Item # _____________________________
C.S.I. Section 11420
GAS BOILER CONVECTION STEAMER ON CABINET BASE WITH 24 QT. TILTING KETTLE
VSX42GT 6 pan capacity
VSX42G5 10 pan capacity
STANDARD FEATURES
Two stainless steel cooking compartments with coved interior corners. Each compartment accepts:
- 1" deep pans (6 - VSX42GT) (10 - VSX42G5)
- 21/2" deep pans (3 - VSX42GT) (5 - VSX42G5)
- 4" deep pans (2 - VSX42GT) (3 - VSX42G5)
11/4" drain in each compartment.
Heavy duty stainless steel "slammable" doors can be opened
and closed at anytime during the cooking cycle. Steam shuts off when door(s) are opened.
Tilting kettle mounted to left of cooking compartments and interconnected to steam generator.
Deck mount dual temperature faucet with 12" swing spout.
200,000 BTU/hr. steam boiler with electronic ignition. Includes
a CSD-1 compliant high pressure limit switch (15 psi), low water cut-off, automatic water ll, automatic generator blow down, 15 psi pressure relief valve and 15 psi kettle connection.
Compartment controls include 60 minute dial timer with buzzer, green "ready" and red "cooking" indicator lights.
Convection steamer mounted on 28" high base cabinet with stainless steel frame, full height doors and side panels with aluminized rear panels with 6" adjustable legs with anged feet for anchoring.
Stainless steel rear ue.
One year limited parts and labor warranty.
OPTIONS
Tilting kettle mounted to the right of the cooking compartment.
Correction facility package:
a. Security type tamper resistant fasteners with tack welds. b. Control cover with hasp (lock by others). c. Cabinet door with hasp (lock by others). d. Perforated ue cover.
Step down transformer for control circuit if higher than 120
volts.
Second year extended limited parts and labor warranty.
ACCESSORIES
Stainless steel back panel.
Interconnecting steam supply plumbing kit.
Removable sliding shelf. Qty. ____.
Water treatment system.
A2780
ISO9001
Vulcan-Hart Co.
MODELS: VSX42G SERIES Gas Heated Convection Steamer on Cabinet Base w/24 Qt. Tilting Kettle
F-32026 (04-06)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
Printed On Recycled Paper
GAS BOILER CONVECTION STEAMER ON CABINET BASE WITH 24 QT. TILTING KETTLE
IMPORTANT:
1. Gas line connecting to unit must be at least 3/4" or larger. If exible connectors are used, the inside diameter must be at least the same as the 3/4" iron pipe and rated for the correct gas input.
2. An adequate ventilation system is required for commercial cooking equipment. Information may be obtained by writing to the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. When writing, refer to NFPA No. 96.
3. These units are manufactured for installation in accordance with ANSZ223.1a (latest edition), National Fuel Gas Code. Copies may be obtained from the American Gas Association, 1515 Wilson Blvd., Arlington, VA 22209.
4. Equipment Clearances: Combustible Non-Combustible
Rear 6" 6" Right/Left 6" 6"
WATER QUALITY STATEMENT:
The fact that a water supply is potable is no guarantee that it is suitable for steam generation. Your water supply must be within these general guidelines:
SUPPLY PRESSURE 20 - 60 psig HARDNESS* less than 3 grains SILICA less than 13 ppm TOTAL CHLORIDE less than 4.0 ppm pH RANGE 7-8 UN-DISSOLVED SOLIDS less than 5 microns * 17.1 ppm = 1 grain of hardness
Other factors affecting steam generation are iron content, amount of chloridation and dissolved gases. Water supplies vary from state to state and from locations within a state. Therefore it is necessary that the local water treatment specialist be consulted before the installation of any steam generating equipment.
SERVICE CONNECTIONS:
Gas supply connection: 3/4" NPT. Natural gas 7" W.C. Propane gas
11" W.C. A gas pressure regulator sized for this unit is included.
Cold water connection: 3/8" NPT for boiler feed. Inlet water pres-
sure between 20 and 80 psi.
Cold water connection: 3/8" NPT for condensate box. Inlet water
pressure between 20 and 80 psi.
Steam take-off connection: 3/4" IPS optional to operate adjacent
equipment.
Electrical connection for controls: 120/60/1 - 300 watts maximum
power supply with ground wire required. (For other than 120 volt supply, consult factory for location of this connection.)
Drain: Condenser box, compartment and boiler 11/4" NPT
(Provide an open air gap type drain within 12" of condenser box and for best results at a distance so that steam vapors will not enter the steamer from underneath the control area. Do not connect solidly to any drain connection.)
NOTE:
• Dimensionswhichlocatetheaboveconnectionshaveatoleranceof + or -3" (+ or -75 mm).
• Installationofbackowpreventers,vacuumbreakersandotherspecic
code requirements is the responsibility of the owner and installer. It is the responsibility of the owner and installer to comply with local codes.
• Plasticdrainsarenotrecommendedduetoinherentlimitedtempera­tures of the plastic. Boiler purge temperatures may exceed 180°F. The installer may be required to provide means to reduce boiler purge water temperature to be that of the condensate temperature of 140°F or less.
• Thisapplianceismanufacturedforcommercialinstallationonlyandis not intended for home use.
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and specications without notice.
F-32026 (04-06)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
Loading...