Vulcan VSP100 Service Manual

INSTALLATION, OPERATION, SERVICE &
PARTS MANUAL
FOR STOCK POT RANGE
MODELS VSP100, VSP200 & VSP300
MODEL VSP100
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791
FORM 30780 (3-92)
IMPORTANT FOR YOUR SAFETY
THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER.
IMPORTANT
IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION OR MODIFICATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
IN THE EVENT OF A POWER FAILURE, DO NOT ATTEMPT TO OPERATE THIS DEVICE.
– 2 –
INSTALLATION, OPERATION, SERVICE & PARTS MANUAL STOCK POT RANGES MODELS VSP100, VSP200 & VSP300 INDEX
PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE
Your Vulcan Stock Pot Range is produced with quality workmanship and material. Proper installation, usage and maintenance of your range will result in many years of satisfactory performance.
The manufacturer suggests that you thoroughly read this entire manual and carefully follow all of the instructions provided.
DESCRIPTION PAGE
INDEX 3 INSTALLATION 4-6
UNCRATING 4 LOCATION 4 INSTALLATION CODES AND STANDARDS 4 GAS CONNECTIONS 4-5 TESTING THE GAS SUPPLY SYSTEM 5 LEVELING THE RANGE 5 VENT 5 ADJUSTMENTS 6
OPERATION 7
CONTROLS 7 LIGHTING AND SHUTTING DOWN PILOTS 7 CLEANING 7
MAINTENANCE 8
LUBRICATION 8
SERVICE 8 TROUBLESHOOTING 8 REPLACEMENT PARTS LIST 9-11
– 3 –
INSTALLATION
NOTE: When installing this appliance, the bottom area
of the range should remain open to allow air circulation for the gas burner. NEVER BLOCK THE BOTTOM AREA OF THE RANGE.
UNCRATING
This stock pot range was inspected before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of the shipment. Immediately after uncrating, check for pos­sible shipping damage. If the range is found to be damaged after unpacking, save the packaging material and contact the carrier within 15 days of delivery.
Before installing, verify that the type of gas supply (natu­ral or propane) agrees with the specifications on the rating plate located on the back of the range. If the supply and equipment requirements do not agree, do not proceed with the installation Contact your dealer or Vulcan-Hart Company immediately.
Do not permit fans to blow directly at the range, and whenever possible, avoid open windows next to the range sides or back. Avoid wall type fans which create air cross currents within the room.
INSTALLATION CODES AND STANDARDS
For proper installation procedures, refer to:
United States
1. State and local codes.
2. National Fuel Gas Code, ANSI-Z223 1 (latest edi­tion). Copies may be obtained from The American Gas Association, 1515 Wilson Blvd Arlington, VA
22209.
Canada
1. Local codes.
LOCATION
This range is design certified for installation in non­combustible locations only.
The equipment area must be kept free and clear of combustible substances.
The range, when installed, must have a minimum clearance of 6" at the sides and 6" at the rear from combustible and non-combustible construction.
The installation location must allow adequate clear­ances for servicing and proper operation. A minimum front clearance of 24" is required.
The range must be installed so that the flow of combus­tion and ventilation air will not be obstructed. Adequate clearance for air openings into the combustion chamber must be provided. Make sure there is an adequate supply of air in the room to allow for combustion of the gas at the burners.
2. CAN/CGA-B149.1 Installation for Natural Gas Burning Appliances and Equipment (latest edition).
3. CAN/CGA B149.2 Installation for Propane Burning Appliances and Equipment (latest edition). Copies may be obtained from The Canadian Gas Associa­tion, 55 Scarsdale Road, Don Mills, Ontario, Canada MSB 2R3.
GAS CONNECTIONS
CAUTION: All gas supply connections and any pipe joint compound used must be resistant to the action of propane gases.
The Model VSP100 Range has one burner, Model VSP200 has two burners, and Model VSP300 has three burners. On all models, each burner has an individual gas connection.
– 4 –