C.S.I. Section 11420
ELECTRIC HEATED CONVECTION STEAMER ON CABINET BASE WITH 24 QT. TILTING KETTLE
VHX42ET 6 pan capacity
VHX42E5 10 pan capacity
STANDARD FEATURES
Two stainless steel cooking compartments with coved interior corners. Each compartment accepts:
- 1" deep pans (6 - VHX42ET) (10 - VHX42E5)
- 21/2" deep pans (3 - VHX42ET) (5 - VHX42E5)
- 4" deep pans (2 - VHX42ET) (3 - VHX42E5)
11/4" drain in each compartment.
Heavy duty stainless steel doors can be opened and closed
at anytime during the cooking cycle. Steam shuts off when door(s) are opened.
Tilting kettle mounted to the left of cooking compartments and interconnected to steam generator.
Deck mount dual temperature faucet with 12" swing spout.
24 KW steam boiler builds 2.3 BHP with a steam ow of 79 lbs.
of steam/hr. Includes a CSD-1 compliant high pressure limit switch (15 psi), low water cut-off, automatic water ll, auto­matic generator blow down, 15 psi pressure relief valve and 15 psi kettle connection.
Compartment controls include 60 minute dial timer with buzzer, green "ready" and red "cooking" indicator lights.
Convection steamer mounted on 28" high base cabinet with stainless steel front full height doors, stainless steel sides, frame and aluminized rear panel with 6" adjustable legs with anged feet for anchoring.
Requires 208 or 240 volt, 60 Hz, 3 phase.
One year limited parts and labor warranty.
A2780
ISO9001
Vulcan-Hart Co.
MODELS: VHX42E SERIES Electric Heated Convection Steamer on Cabinet Base with 24 qt. Tilting Kettle
SPECIFICATIONS:
Electric heated convection steamer, Vulcan-Hart Model No. (VHX42ET) (VHX42E5). Two stainless steel cooking compart­ments with coved interior corners. Heavy duty stainless steel door can be opened and closed at anytime during the cooking cycle. Steam shuts off when door(s) are opened. Tilting kettle mounted to left of cooking compartments and interconnected to steam generator. Deck mount dual temperature faucet with 12" swing spout. Convection steamer mounted on 28" high base cabinet with stainless steel front full height doors, stainless steel sides, frame and aluminized rear panel with 6" adjustable legs with anged feet for anchoring. 24 KW steam boiler builds 2.3 BHP with a steam ow of 79 lbs. of steam/hr. Includes a CSD-1 compliant high pressure limit switch (15 psi), low water cut-off, automatic water ll, automatic generator blow down, 15 psi pressure relief valve and 15 psi kettle connection. Com partment controls include 60 minute dial timer with buzzer, green "ready" and red "cooking" indicator lights. Requires 208 or 240 volt, 60 Hz,
3 phase.
Exterior dimensions: VHX42ET 42"w x 35.4"d x 603/8"h. VHX42E5 42"w x 35.4"d x 73"h.
U L listed. Classied by U L to NSF Std. #4. Meets ASME code.
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
F-35450 (02-06)
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
OPTIONS
36 KW, 208 or 240 volt, 60 Hz, 3 phase.
42 KW, 208 volt, 60 Hz, 3 phase.
48 KW, 240 volt, 60 Hz, 3 phase.
Tilting kettle mounted to the right of the cooking compart-
ments.
Correction facility package:
a. Security type tamper resistant fasteners with tack welds. b. Control cover with hasp (lock by others). c. Cabinet door with hasp (lock by others).
480 volts, 60 Hz, 3 phase.
Second year extended limited parts and labor warranty.
ACCESSORIES
Stainless steel back panel.
Interconnecting steam supply plumbing kit.
Removable sliding shelf. Qty. ____.
Water treatment system.
Printed On Recycled Paper
ELECTRIC HEATED CONVECTION STEAMER ON CABINET BASE WITH 24 QT. TILTING KETTLE
WATER QUALITY STATEMENT:
The fact that a water supply is potable is no guarantee that it is suitable for steam generation. Your water supply must be within these general guidelines:
SUPPLY PRESSURE 20 - 60 psig HARDNESS* less than 3 grains SILICA less than 13 ppm TOTAL CHLORIDE less than 4.0 ppm pH RANGE 7-8 UN-DISSOLVED SOLIDS less than 5 microns * 17.1 ppm = 1 grain of hardness
Other factors affecting steam generation are iron content, amount of chloridation and dissolved gases. Water supplies vary from state to state and from locations within a state. Therefore it is necessary that the local water treatment specialist be consulted before the installation of any steam generating equipment.
STEAM FLOW RATE AT 10 PSIG AT THE KETTLE
Fast Boil
12 minutes
lbs/hr kg/hr lbs/hr kg/hr lbs/hr kg/hr
6 gallons 39 18 21 10 14 6
NOTE:
1. The energy required to bring 70°F water to 212°F.
2. 1 boiler horsepower (BHP) = 34.5 lbs. of steam per hour.
BRIMFUL CAPACITIES (In 4 oz servings):
Working capacity 70 to 80% of brimful depending on model. 24 quarts/6 gallons/23 liters/192 servings
Medium Boil
20 minutes
Slow Boil
30 minutes
SERVICE CONNECTIONS:
Electric Connection: Junction box for electrical connection
for boiler heat.
Drain: Condenser box, compartment and boiler 11/4" NPT
(Provide an open air gap type drain within 12" of condenser box and for best results at a distance so that steam vapors will not enter the steamer from underneath the control area. Do not connect solidly to any drain connection.)
Cold Water Connection: 1/2" NPT for boiler feed. Inlet water
pressure between 20 and 80 psi.
Cold Water Connection: 1/8" NPT for condensate box. Inlet
water pressure between 20 and 80 psi.
Water: For swing faucet, (single) (dual) temperature 1/4" IPS
tailpiece.
Steam Take-Off Connection: 3/4" NPT.
NOTE:
• Dimensionswhichlocatetheaboveconnectionshaveatoleranceof
+ or -3" (+ or -75 mm).
• Installationofbackowpreventers,vacuumbreakersandotherspe-
cic code requirements is the responsibility of the owner and installer. It is the responsibility of the owner and installer to comply with local codes.
• Plasticdrainsarenotrecommendedduetoinherentlimitedtempera-
tures of the plastic. Boiler purge temperatures may exceed 180°F. The installer may be required to provide means to reduce boiler purge water temperature to be that of the condensate temperature of 140°F or less.
• Thisapplianceismanufacturedforcommercialinstallationonlyandis
not intended for home use.
PAN CAPACITIES (Per compartment)
MODEL 1" deep 21/2" deep 4" deep
VHX42ET 6 3 2
VHX42E5 10 5 3
Total
Conn.
KW
208 240 480 380/50/60, 4 wire 208 240
24 66.0 58 29 31 116 100
36 99.9 86.6 43.3 46 N/A N/A
42 118 N/A N/A N/A N/A N/A
48 N/A 116 58 62 N/A N/A
NOMINAL AMPS PER LINE
Three Phase Single Phase
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and
specications without notice.
F-35450 (02-06)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028