SPECIFICATIONS:
Gas heated convection steamer, Vulcan-Hart Model No.
(VHX24G)(VHX24G5). Convection steamer mounted on 28" high
base cabinet with stainless steel frame, front full height doors,
slip-off stainless steel side and aluminized rear panel with 6"
adjustable legs with anged feet for anchoring. Two stainless
steel cooking compartments with coved interior corners. 11/4"
drain in each compartment. Heavy duty stainless steel "slammable"
doors can be opened and closed at anytime during the cooking
cycle. Steam shuts off when door(s) are opened. 270,000 BTU/hr.
high efciency steam boiler with electronic ignition builds 5.5
BHP. Includes CSD-1 compliant high pressure limit switch (15
psi), low water cut-off, automatic water ll, automatic generator
blowdown, 15 psi pressure relief valve and 15 psi kettle connection. Compartment controls include 60 minute dial timer with
buzzer, green "ready" and red "cooking" indicator lights. Stainless
steel cover ue. Service connections include 1" gas connection
with gas pressure regulator, 1/2 " cold water connection for boiler
feed and 1/8" cold water condenser, 120 volt control circuit and
11/4" drain connection.
Exterior dimensions: 24"w x 35.4"d x (60.37)(73")"h.
CSA design certied. Meets ASME code. Classied by U L to
NSF Std. #4.
SPECIFY TYPE OF GAS WHEN ORDERING.
SPECIFY ALTITUDE WHEN ABOVE 2,000 FT.
Item # _____________________________
C.S.I. Section 11420
VHXG SERIES
HIGH EFFICIENCY GAS CONVECTION STEAMERS
ON CABINET BASE
■ VHX24G 6 pan capacity
■ VHX24G5 10 pan capacity
STANDARD FEATURES
■ Convection steamer mounted on 28" high base cabinet with
stainless steel frame, front full height doors, slip-off stainless
steel side and aluminized rear panel with 6" adjustable legs
with anged feet for anchoring.
■ Two stainless steel cooking compartments with coved interior
corners. Each compartment accepts:
- 1" deep pans (6 - VHX24G)(10 - VHX24G5)
- 21/2" deep pans (3 - VHX24G)(5 - VHX24G5)
- 4" deep pans (2 - VHX24G)(3 - VHX24G5)
■ 11/4" compartment drain.
■ Heavy duty stainless steel "slammable" doors can be opened
and closed at anytime during the cooking cycle. Steam shuts
off when door(s) are opened.
■ 270,000 BTU/hr. high efciency steam boiler with electronic
ignition builds 5.5 BHP. Includes CSD-1 compliant high pressure limit switch (15 psi), low water cut-off, automatic water ll,
automatic generator blowdown, 15 psi pressure relief valve
and 15 psi kettle connection.
■ Compartment controls include 60 minute dial timer with
buzzer, green "ready" and red "cooking" indicator lights.
■ Stainless steel ue cover.
■ Service connections include 1" gas connection with gas
pressure regulator, 1/2" cold water connection for boiler feed
and 1/8" cold water condenser, 120 volt control circuit and 11/4"
drain connection. (See detail on back page.)
■ One year limited parts and labor warranty.
OPTIONS
■ Correction facility package:
a. Cabinet door with hasp (lock by others).
b. Control cover (lock by others).
c. Tamper resistant fasteners.
d. Flue riser cover.
■ Mount and interconnect boiler base with kettle at factory.
Includes steam supply piping. Shipped on one skid.
■ Second year extended limited parts and labor warranty.
ACCESSORIES
■ Stainless steel back panel.
■ Interconnecting steam supply plumbing kit.
■ Removable sliding shelf. Qty.___.
■ Water treatment system.
A2780
ISO9001
Vulcan-Hart Co.
MODEL: VHXG SERIES High Efficiency Gas Convection Steamers on Cabinet Base
F-32400 (08-04)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
VHXG SERIES
HIGH EFFICIENCY GAS CONVECTION STEAMERS
ON CABINET BASE
SERVICE CONNECTIONS
GAS CONNECTION: 1" NPT.
ELECTRICAL CONNECTION FOR CONTROLS: 120/60/1,
300 watt maximum, power supply with grounding wire
required. (For other than 120 volt supply consult factory for
location of this connection.)
DRAIN: Condenser box, compartment and boiler, 11/4" NPT.
Provide an open air gap type drain within 12" of condenser box
and for best results at a distance so that steam vapors will not
enter the steamer from underneath the control area. Do not
connect solidly to any drain connection.
COLD WATER CONNECTION: 1/2" NPT for boiler feed. Inlet
water pressure between 20 and 80 psi.
COLD WATER CONNECTION: 1/8" NPT for condensate box.
Inlet water pressure between 20 and 80 psi.
STEAM TAKE-OFF CONNECTION: 3/4" NPT.
NOTE:
• Dimensionswhichlocatetheaboveconnectionshaveatoleranceof
+ or -3" (+ or -75 mm).
• Installation of backow preventers, vacuum breakers and other
specic code requirements is the responsibility of the owner and
installer. It is the responsibility of the owner and installer to comply
with local codes.
• Plasticdrainsarenotrecommendedduetoinherentlimitedtem
peratures of the plastic. Boiler purge temperatures may exceed
180°F. The installer may be required to provide means to reduce
boiler purge water temperature to be that of the condensate temperature of 140°F or less.
• Thisapplianceismanufacturedforcommercialinstallationonlyand
is not intended for home use.
IMPORTANT
1. A pressure regulator sized for this unit is included. Minimum supply
pressure: Natural gas 7" W.C., Propane gas 11" W.C.
2. Gas line connecting to unit must be 1" or larger. If exible connectors
are used, the inside diameter must be at least the same as the 1" iron
pipe.
3. An adequate ventilation system is required for commercial cooking
equipment. Information may be obtained by writing to the National
Fire Protection Association, Batterymarch Park, Quincy, MA 02289.
When writing, refer to NFPA No. 96.
4. These units are manufactured for installation in accordance with
ANSZ223.1A (latest edition), National Fuel Gas Code. Copies may
be obtained from the American Gas Association, 1515 Wilson Blvd.,
Arlington, VA 22209.
5. Clearance: Combustible Non-Combustible
Rear 6" 6"
Left & Right Side 6" 6"
WATER QUALITY STATEMENT:
The fact that a water supply is potable is no guarantee that it is suitable
for steam generation. Your water supply must be within these general
guidelines:
SUPPLY PRESSURE 20 - 60 psig
HARDNESS* less than 3 grains
SILICA less than 13 ppm
TOTAL CHLORIDE less than 4.0 ppm
pH RANGE 7-8
UN-DISSOLVED SOLIDS less than 5 microns
* 17.1 ppm = 1 grain of hardness
Other factors affecting steam generation are iron content, amount of
chloridation and dissolved gases. Water supplies vary from state to state
and from locations within a state. Therefore it is necessary that the local
water treatment specialist be consulted before the installation of any
steam generating equipment.
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and
specications without notice.
F-32400 (08-04)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602