Vulcan VH3616E User Manual

Item # __________________________
C.S.I. Section 11420
VH3616E
ELECTRIC HEATED CONVECTION STEAMER ON CABINET BASE
VH3616E 36" wide base
STANDARD FEATURES
Two stainless steel cooking compartments with coved interior corners. Each compartment accepts sixteen 1" deep, eight
1
2
/2" deep or four 4" deep 12" x 20" pans.
1
1
/4" drain in each compartment.
Heavy duty stainless steel "slammable" doors can be opened and closed at anytime during the cooking cycle. Steam shuts off when door(s) are opened.
Steamer mounted on 28" high base cabinet with stainless steel frame, front full height doors, slip-off stainless steel sides and aluminized rear panel with 6" adjustable legs with flanged feet for anchoring.
42/48 KW electric steam boiler builds 4/4.6 BHP. Includes CSD-1 compliant high pressure limit switch (15 psi), low water cut-off, automatic water fill, automatic boiler blowdown, 15 psi pressure relief valve and 15 psi kettle connection.
1
Service connections include boiler feed and
1
/2" cold water condenser and 11/4" drain
connection.
One year limited parts and labor warranty.
/2" cold water connection for
Vulcan-Hart Co.
ISO9001
A2780
MODEL: VHLE SERIES
Electric heated convection steamer, Vulcan-Hart Model No. VH3616E. Two stainless steel cooking compartments with coved interior corners. Each compartment accepts sixteen 1" deep,
1
eight 2
/2" deep or four 4" deep 12" x 20" pans. 11/4" drain in each compartment. Heavy duty stainless steel "slammable" doors can be opened and closed at anytime during the cooking cycle. Steam shuts off when door(s) are opened. Steamer mounted on 28" high base cabinet with stainless steel frame, front full height doors, slip-off stainless steel sides and aluminized rear panel with 6" adjustable legs with flanged feet for anchoring. 42/48 KW steam boiler builds 4/4.6 BHP. Includes CSD-1 compliant high pressure limit switch (15 psi), low water cut-off, automatic water fill, automatic boiler blowdown, 15 psi pressure relief valve and 15 psi kettle connection. Service connections include: connection for boiler feed and
1
1
/4" drain connection.
1
/2" cold water condenser and
1
/2" water
Exterior dimensions: 36"w x 35
7
/16"d x 66"h.
UL listed. UL classified to Canadian safety standards. Classified by U L to NSF Std. #4. Meets ASME code.
OPTIONS
Correction facility package:
a. Cabinet door with hasp (lock by others). b. Security type tamper resistant fasteners. c. Control cover (lock by others).
Second year extended limited parts and labor warranty.
ACCESSORIES
Water treatment system.
Stainless steel back panels.
Removable 12 x 20 sliding shelf (Qty.____).
Super Steamer, Electric Boiler
F-32614 (5-04)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
VH3616E
ELECTRIC HEATED CONVECTION STEAMER ON CABINET BASE
SERVICE CONNECTIONS:
ELECTRICAL CONNECTION: Junction box for electrical con-
nection for boiler heat and controls.
DRAIN: Condenser box, compartment and boiler, 11/2" NPT. (Provide an open air type drain within 12" of condenser box and for best results at a distance so that steam vapors will not enter the steamer from underneath the control area. Do not connect solidly to any drain connections.)
COLD WATER CONNECTION: 1/2" NPT for boiler feed. Inlet water pressure between 20 and 80 psi.
COLD WATER CONNECTION: 1/2" NPT for condensate box. Inlet water pressure between 20 and 80 psi.
WATER: For swing faucet, (single) (dual) temperature 1/4" IPS tailpiece.
STEAM TAKE-OFF CONNECTION: 3/4" NPT.
Total
Conn.
KW 208 240 480 380/50/60, 4 wire 208 240
42 118 N/A N/A N/A N/A N/A 48 N/A 116 58 62 N/A N/A
PAN CAPACITIES (Per compartment)
NOMINAL AMPS PER LINE
Three Phase Single Phase
1" deep 21/2" deep 4" deep
16 8 6
NOTE:
• Dimensions which locate the above connections have a tolerance of + or -3" (+ or -75 mm).
• Installation of backflow preventers, vacuum breakers and other specific code requirements is the responsibility of the owner and installer. It is the responsibility of the owner and installer to comply with local codes.
• Plastic drains are not recommended due to inherent limited tempera­tures of the plastic. Boiler purge temperatures may exceed 180°F. The installer may be required to provide means to reduce boiler purge water temperature to be that of the condensate temperature of 140°F or less.
• This appliance is manufactured for commercial installation only and is not intended for home use.
WATER QUALITY STATEMENT:
The fact that a water supply is potable is no guarantee that it is suitable for steam generation. Your water supply must be within these general guidelines:
SUPPLY PRESSURE 20 - 60 psig HARDNESS* less than 3 grains SILICA less than 13 ppm TOTAL CHLORIDE less than 4.0 ppm pH RANGE 7-8 UN-DISSOLVED SOLIDS less than 5 microns
* 17.1 ppm = 1 grain of hardness
Other factors affecting steam generation are iron content, amount of chloridation and dissolved gases. Water supplies vary from state to state and from locations within a state. Therefore it is necessary that the local water treatment specialist be consulted before the installation of any steam generating equipment.
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and specifications without notice.
F-32614 (5-04)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
Printed On Recycled Paper
Loading...