Vulcan GDC24 User Manual

Item # __________________________
C.S.I. Section 11420
GAS DUPLEX™ COOKER
GENERAL INFORMATION: Vulcan duplex cookers combine a flat griddle surface with a swing-down heated top platen to provide two sided cooking. Griddles are available in 24", 36", 48", 60" and 72" widths. Top platens have a removable cooking shoe with a non-stick cooking surface. Top platens may be specified over any portion or all of the griddle plate.
STANDARD FEATURES
Stainless steel front, sides, back splashers and 4" legs.
Spatula width front grease trough feeds into two removable
side mounted stainless steel grease collectors.
1" thick rolled steel griddle plate, machine ground and polished.
30,000 BTU/hr. input for each 12" of griddle width.
Electronic pilot ignition.
One solid state temperature control for each 12" of griddle
width. Step-down transformer provided for control circuit.
Gas pressure regulator and manual shut-off valve.
Top platens with removable non-stick cooking shoes available
in 208 volt, 1 or 3 phase, 2.0 KW input, or 240 volt, 1 or 3 phase,
2.67 KW input.
One solid state temperature control for each top platen. Step-down transformer provided for control circuit.
Counter balanced lift assists hold each platen in the “UP” position when raised.
135 day warranty on the non-stick surface of the cooking shoe, one year limited parts and labor warranty on the balance of the unit.
Vulcan-Hart Co.
ISO9001
A2780
SPECIFICATIONS:
Combination gas and electric two sided duplex cooker, Vulcan­Hart model no. GDC _________. Base griddle unit has stainless steel front, sides, back splashers and 4" legs. (24")(36")(48") (60")(72") wide 1" thick steel griddle plate is machine ground and polished. Spatula width front grease trough feeds into two removable side mounted stainless steel grease collectors. 30,000 BTU/hr. input for each 12" of griddle width. Electronic pilot ignition. One solid state temperature control for each 12" of griddle width. Step-down transformer provided for control circuit. Gas pressure regulator and manual gas shut-off valve.
Top cooking platens located in position(s) (specify from left to right: A, B, C, D, E, F). Counter balanced lift assists hold each individual plate in the “UP” position when raised. Each platen has a removable cooking shoe with a non-stick cooking surface. (2 KW, 208 volt, 1 or 3 phase) (2.67 KW, 240 volt, 1 or 3 phase) input per platen. One solid state temperature control for each top platen. Step-down transformer provided for control circuit.
Listed by U L and NSF.
SPECIFY VOLTAGE, PHASE AND TYPE OF GAS WHEN ORDERING. SPECIFY ALTITTUDE WHEN ABOVE 2,000 FT.
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
F-31833 (12-01)
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
OPTIONS
Stainless steel floor stand with 6" legs and undershelf.
Set of four 4" diameter casters (two locking) for floor stand.
Towel bar.
3
7
8" wide cutting board. (NOTE: Cutting board is not available
on models that have a towel bar).
Power cord connection. Specify NEMA plug configuration
(15-50 or 15-60). Available on 24", 36" and 48" models only. Direct wire connection required on 60" and 72" models.
ACCESSORIES
Flexible gas hose with quick disconnect and restraining
device. Consult price book for available sizes.
GDC SERIES
Gas Duplex
Cooker
GAS DUPLEX COOKER
IMPORTANT
1. A gas pressure regulator sized for this unit is installed.
2. An adequate ventilation system is required for commercial cooking equipment. Information may be obtained by writing to the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
When writing refer to NFPA No. 96.
3. All models require a 6" clearance at both sides and rear adjacent to combustible construction.
NOTE: Floor models are shipped with 4" adjustable casters. Specify if adjustable bullet style legs are desired in place of casters.
Counter models are shipped with adjustable 6" legs. Counter models are designed to be used on either a refrigerated base or a stand. Counter models must be installed with legs in place to insure space height is correct for platens to swing up freely.
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and specifications without notice.
F-31833 (12-01)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028