Vulcan ERC50F Installation Manual

OPERATION MANUAL
KLEENSCREEN FILTRATION SYSTEM
SUPPLEMENT INSTRUCTION MANUAL FOR:
Gas Fryer Models
GRD35F ML-126732 GRD45F ML-126735 GRD65F ML-126738 GRD85F ML-126741
GRC35F ML-126733 GRC45F ML-126736 GRC65F ML-126739 GRC85F ML-126742
Electric Fryer Models
ERD50F ML-135561 ERD85F ML-135563
ERC50F ML-135565 ERC85F ML-135567
For additional information on Vulcan-Hart Company or to locate an authorized
parts and service provider in your area, visit our website at www.vulcanhart.com
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791
2ERD50F
2GRD45F
FORM 35616 (Nov. 2003)
Table of Contents
GENERAL............................................................................................................................................. 3
ASSEMBLY .................................................................................................................................... 3
CONTROLS AND COMPONENT LOCATIONS — GAS FRYERS.................................................... 4
CONTROLS AND COMPONENT LOCATIONS — ELECTRIC FRYERS ......................................... 5
OPERATION ........................................................................................................................................ 6
FILTERING PROCEDURE WHEN USING LIQUID SHORTENING ............................................ 6
FILTERING PROCEDURE WHEN USING SOLID SHORTENING ............................................. 7
FILTERING TIPS............................................................................................................................ 8
PERIODICALLY REMOVE EXCESS DEBRIS FROM THE FILTER ........................................... 8
FLUSH AND DISCARD.................................................................................................................. 8
MAINTENANCE ................................................................................................................................. 10
CLEANING THE FILTER DRAWER............................................................................................ 10
FRYER BOIL-OUT INSTRUCTIONS .......................................................................................... 11
TROUBLESHOOTING ....................................................................................................................... 12
SERVICE ...................................................................................................................................... 12
– 2 –
OPERATION AND CARE OF
KLEENSCREEN FILTRATION SYSTEM
SAVE THESE INSTRUCTIONS
GENERAL
The KleenScreen Filtration System filters the oil as it is pumped back to its respective tank. Valves inside the doors under each fry tank must be set so only one tank is being drained, filtered and pumped back at any one time.
The KleenScreen Filtration System is used on the following Vulcan Fryer Models:
Gas Fryers Electric Fryers
GR35F GRD35F GRC35F ERD50F ERC50F GR45F GRD45F GRC45F ERD85F ERC85F GR65F GRD65F GRC65F GR85F GRD85F GRC85F
ASSEMBLY
1. After unpacking, wash the filter tank, crumb basket and filter screen. Use dishwashing detergent and warm water, or clean the components in a dishwasher. Rinse the filter tank, crumb basket and filter screen thoroughly. Wipe components dry with a clean cloth.
2. Pull the filter drawer out.
3. Place the filter tank in the filter drawer. Hang the crumb basket from the left tank handle inside the filter tank (Figs. 1 and 2). Position the filter screen assembly flat on the bottom of the filter tank so the filter orifice underneath the screen fits the suction hole in the bottom of the tank (Figs. 1 and 2). Close the drawer.
4. Make sure the two O-Rings are in place inside the filter suction port (Figs. 1 and 2). As the drawer is closed, make sure the filter suction connector fits tightly into the filter suction port (Figs. 1 and 2).
– 3 –
CONTROLS AND COMPONENT LOCATIONS — Gas Fryers
The filter tank cover is removed to show component locations.
Fig. 1
– 4 –