Vollrath 69722C-1-SR Operator’s Manual

Down Draft Vent Module with Induction Range(s)
Thank you for purchasing this Vollrath equipment. Before operating the equipment, read and familiarize yourself with the following operating and safety instructions. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Save the original box and packaging. Use this packaging to ship the equipment if repairs are needed.
SAFETY PRECAUTIONS
To ensure safe operation, read the following statements and understand their meaning. This manual contains safety precautions which are explained below. Please read carefully.
WARNING
Warning is used to indicate the presence of a hazard that will or can cause severe personal injury or death.
CAUTION
Caution is used to indicate the presence of a hazard that will or can cause minor or major personal injury if the caution is ignored.
Operator’s Manual
NOTICE: Notice is used to note information that is important but not
hazard-related.
To reduce risk of injury or damage to the equipment:
• Use only grounded electrical outlets matching the nameplate rated voltage.
• Have the equipment installed by a qualified personnel in accordance with local codes and ordinances.
• Use the equipment in a flat, level position.
• Do not use an extension cord with this equipment. Do not plug this equipment into a power strip or multi-outlet power cord.
• Unplug the equipment, turn off and let it cool before cleaning or moving.
• Do not spray controls or outside of the equipment with liquids or cleaning agents.
• Do not operate unattended.
• Do not operate if the equipment has been damaged or is malfunctioning in any way.
FUNCTION AND PURPOSE
This equipment is intended for cooking food and removing grease­laden air. It includes integrated fire suppression. It is intended for use in commercial foodservice operations only. It is not intended for household, industrial or laboratory use. No other use is recommended or authorized by the manufacturer or its agents.
Item No. Description
9718C-1-VCL V-Class Custom, 18" Food Guard, 1-Hob, Operator Left 69718C-1-VCR V-Class Custom, 18" Food Guard, 2-Hob, Operator Right 69718C-2-VC V-Class Custom, 18" Food Guard, 2-Hob 69722C-1-VCL V-Class Custom, 22" Food Guard, 1-Hob, Operator Left 69722C-1-VCR V-Class Custom, 22" Food Guard, 1-Hob, Operator Right 69722C-2-VC V-Class Custom, 22" Food Guard, 2-Hob
®
69718C-1-SL Signature Server 69718C-1-SR Signature Server 69718C-2-S Signature Server 69722C-1-SL Signature Server 69722C-1-SR Signature Server 69722C-2-S Signature Server
, 18" Food Guard, 1-Hob, Operator Left
®
, 18" Food Guard, 1-Hob, Operator Right
®
, 18" Food Guard, 2-Hob
®
, 22" Food Guard, 1-Hob, Operator Left
®
, 22" Food Guard, 1-Hob, Operator Right
®
, 22" Food Guard, 2-Hob
Table of Contents
System Overview ........................................................ 2
Unpacking ................................................................... 3
Setting Up the Equipment ........................................... 3
Fire Suppression System Installation .......................... 4
Downdraft Vent Operation ........................................... 5
Fire Suppression System Operation ............................ 7
Induction Range Operation ......................................... 8
Register your product at Vollrath.com/registration and become eligible to win a free 10" Vollrath Tribute©fry pan.
©
2018 The Vollrath Company L.L.C. Part No. 2350226-1 ml 3/9/18
SYSTEM OVERVIEW
The Downdraft Vent Module consists of three integrated systems:
• Downdraft Vent
• ANSUL
• Cooking Appliance(s)
®
R-102 Restaurant Fire Suppression System
A
B
C
D
A
J
I
H G
F
E
A Discharge Nozzles (4 total) B Grease Filters (2 total) C Grease Tray Location (1 total) D Downdraft Vent Module Control Panel E Agent Tank Location F Fire Suppression System Arming View Window G Induction Range Control Panel(s) H Manual Pull Station
I Particulate Filters (2 total)
J Downdraft Vent Shroud
2 Down Draft Vent Module with Induction Range(s) Operator’s Manual
UNPACKING
NOTICE: Do not discard the carton or other packing materials until
you have inspected the equipment and tested it for proper operation.
1. Remove all packing material and tape, as well as any protective plastic from the equipment. When no longer needed, dispose of all packaging and materials in an environmentally responsible manner.
2. Clean any glue residue left over from the plastic or tape.
3. Read and understand all labels and diagrams installed on equipment.
4. Carefully check for and account for all components and accessories before discarding packaging materials.
5. Place the Downdraft Vent Module on a stable, level surface.
SETTING UP THE EQUIPMENT
Toe Kick Installation
If your Downdraft Vent Module includes toe kicks, they will need to be installed. There are four toe kicks, one for each side of the base. The operator side toe kick is open in the middle.
6. Level the Downdraft Vent Module. The included adjustable legs can be used to level the Downdraft Vent Module or align it with other equipment. Leg length is adjusted by rotating the leg. Adjust each leg until the Downdraft Vent Module sets firmly on all legs and is level front-to-back and side-to-side.
7. If applicable, install the included toe kicks.
8. Ensure a properly grounded electrical supply matching the nameplate rating is available to the unit.
9. Contact your local ANSUL dealer to install the fusible links, apply power, test, charge, arm, and commission the ANSUL Fire Suppression System. Go to ANSUL.com to find a local dealer.
Install the Toe Kicks
Tools Required
Right-angle drill
Remove or Loosen Screws from the Base
The V-Class base is illustrated. Installation on a Signature Server®base is similar.
Remove
Loosen
Loosen
Remove
Remove
Loosen
Remove
1. Remove the corner screws from the base. There are two in each corner. Retain for installing the toe kicks.
2. On the operator and customer sides of the base, remove the screw adjacent to the corner. Retain for installing the toe kicks.
3. Loosen the remaining screws – two on each side of the base.
Loosen
Overlap corners
Align notches with screws
Alignnotches with screws
1. Install the customer side toe kick:
Align the notches on the toe kick to the middle screws on the base. Slide the toe kick onto the middle screws. Insert the screws adjacent to the corner. Tighten the screws just enough to hold the toe kick in place.
2. Install the end toe kicks:
Position the end of the toe kick so it is overlapped by the customer side toe kick. Align the notches on the toe kicks to the middle screws. Tighten the screws just enough to hold the toe kick in place. Follow the same process to install the other toe kick to the other end of the base.
3. Reinstall and tighten the corner screws on the customer side of the base.
4. Install the operator side toe kick: Position the end of the toe kick so it is overlaps the end toe kicks. Align the notches on the toe kick to the middle screws on the base. Slide the toe kick onto the middle screws. Insert the screws adjacent to the corner. Tighten the screws just enough to hold the toe kick in place.
5. Reinstall and tighten the corner screws on the operator side of the base.
6. Tighten all screws until the toe kicks are securely installed.
Down Draft Vent Module with Induction Range(s) Operator’s Manual 3
FIRE SUPPRESSION SYSTEM INSTALLATION
WARNING
Fire, Injury, Death Hazard
This equipment must installed and adjusted by a qualified technician in accordance with all federal, state and local codes. Failure to install adjust or maintain this equipment properly can result in property damage, injury or death.
NOTICE: The ANSUL Fire Suppression System must be charged by
NOTICE: It is the installer’s responsibility to verify that this
an authorized ANSUL representative. The Downdraft Vent Module will not operate and cooking appliance will not be energized until the ANSUL Fire Suppression System has been charged.
equipment installation is in compliance with the specifications listed in this manual, ANSUL documentation, local code requirements, and NFPA standards.
The following instructions are for use only by authorized ANSUL representatives. Refer to ANSUL documentation for the following steps.
ANSUL representative to supply:
or nitrogen cartridge
•CO
2
• ANSULEX Low pH Liquid Fire Suppressant
Fusible Links and Gas Cartridges
A
A
A
B
A ANSUL Model SL Fusible Link 165° F B LT-20-R Cartridge
1. Replace the four temporary test links with the supplied 165°F SL
Fusible Links. Refer to Particulate Filter Replacement on page 6 for instructions for removing the particulate filters.
2. Install the CO release/bracket assembly.
or nitrogen cartridges onto the ANSUL automatic
2
Fire Extinguishing Tank and Nozzles
A
A ANSUL R-102 1W Nozzle (Appliance) B ANSUL R-102 1W Nozzle (Duct) C ANSUL R-102 1¹⁄₂ Gallon Tank
Fill the agent tank with ANSULEX low pH Liquid Fire Suppressant.
A
B
B
C
4 Down Draft Vent Module with Induction Range(s) Operator’s Manual
DOWNDRAFT VENT OPERATION
Overview
The Downdraft Vent Module control panel will be operational only when:
• The ANSUL Fire Suppression System is charged.
• The grease filters and the particulate filters are in position.
BA C D
main power
system start low high
when illuminated~ check for missing or wrong lter(s)
when illuminated~ check for dirty or wrong lter(s)
EF
A Main Power Light. Indicates power to the Downdraft Vent
Module is ON.
B Vent Light. Indicates the downdraft vent is ON. C Low Light. Troubleshooting light. Indicates a filter is missing,
installed incorrectly or is the wrong filter.
D High Light. Troubleshooting light. Indicates the filters are dirty
or are the wrong filter for this unit.
E System Start Switch. Switches ON the downdraft vent. F Main Power Switch. Switches the Downdraft Vent Module ON
or OFF.
Operation
1. Press the Main Power switch to the ON position.
2. Press and release the momentary System Start switch.
3. When the Low indicator light is no longer illuminated, you can begin using the induction hob(s) for cooking.
Shutdown
1. Turn off the cooking appliance.
2. Press the Main Power switch to the OFF position.
Cleaning
Clean your Downdraft Vent Module daily.
WARNING
Electrical Shock Hazard
Keep water and other liquids from entering the inside of the equipment. Liquid inside the equipment could cause an electrical shock. Do not spray water or cleaning products. Liquid could contact the electrical components and cause a short circuit or an electrical shock.
CAUTION
Burn Hazard
Do not touch hot liquid or heating surfaces while unit is heating or operating.
Hot liquids and food can burn skin. Induction heating surfaces heat very rapidly. Allow the heating surface to cool before handling.
NOTICE: Do not use abrasive materials, scratching cleansers or
scouring pad to clean the unit. These can damage the finish.
Wipe the Equipment Exterior
1. Wipe the equipment exterior.
2. Unplug the equipment and let it completely cool.
3. Use a clean damp cloth. If needed, use a mild soap only.
4. Thoroughly wipe off any mild soap. Residue could corrode the surface of the unit.
Wash grease filters, grease tray and downdraft vent shroud
NOTICE: Failure to install grease tray will allow grease and
moisture from grease tray to drop into the vent, creating both a safety hazard and a health hazard
NOTICE: DO NOT wash particulate filters. Washing will clog the
filter and cause the cooking appliance to be disabled. Dirty particulate filters must be replaced. See Maintenance on page 6.
1. Remove the grease filters, grease tray and downdraft vent shroud. Components lift off. No tools are required.
2. Empty the grease tray into an appropriate grease collection receptacle.
3. Wash the components in a dish washing machine or in a sink with mild detergent and warm water.
4. Rinse the components with clean water.
5. Dry the components with a clean non-abrasive cloth.
6. Re-install the components.
7. Visually inspect the four discharge nozzles. Verify the nozzle caps are in place. Contact your local ANSUL authorized representative if the caps are missing and/or the nozzles need to be repositioned.
Down Draft Vent Module with Induction Range(s) Operator’s Manual 5
DOWNDRAFT VENT OPERATION (CONTINUED)
Maintenance
Particulate Filter Replacement NOTICE: Replace filters every six months or sooner if they become clogged.
1. Remove the grease filters to access the particulate filters. 2. To install a replacement filter, note the air flow direction arrow on the
Particulate filter
particulate filter. Position the filter so the airflow arrow points down.
3. Place the filter into the base of the downdraft vent shroud.
4. Re-install the grease filters.
Troubleshooting
Problem Might be Caused By Course of Action
• Reconnect to electrical power.
Downdraft Vent Module will not operate. Main Power light is not illuminated.
Low indicator light illuminated and cooking unit will not turn on.
High indicator light illuminated and cooking unit will not turn on.
No power.
ANSUL Fire Suppression System not properly commissioned or in need of service.
Particulate or grease filters not in position, missing or incorrect type.
Particulate or grease filters dirty or incorrect type.
• Reset circuit breaker for unit.
• Contact Vollrath Technical Services.
Contact an authorized ANSUL representative for repair.
Properly install correct filters.
Install correct clean filters.
6 Down Draft Vent Module with Induction Range(s) Operator’s Manual
FIRE SUPPRESSION SYSTEM OPERATION
NOTICE: Please refer to the included ANSUL Owner’s Guide for more detailed information.
Owners Role in Fire Protection
• Keep all kitchen equipment free of grease build-up.
• Never use or store flammable solvents or cleaners on or near the equipment.
• Keep utensils, pots, pans cooking material, etc., stored in areas that do not obstruct the Fire Suppression System discharge.
• Never tamper with the system components (i.e., detectors, nozzles, agent storage container(s), releasing mechanism).
• DO NOT remove or reposition the nozzles. All nozzles have been factory installed and aligned in the proper operating position. Be sure that all nozzles have nozzle caps assembled to them. Contact your local ANSUL authorized representative if caps are missing and/ or nozzles need to be repositioned.
Controls and Operation
In the unlikely event of a fire:
• The integrated ANSUL Fire Suppression System will automatically deploy.
• Power to the cooking appliance and the entire Downdraft Vent Module will be shut off.
Manual Activation
The ANSUL Fire Suppression System can also be manually activated.
1. Pull the ring on the red manual pull station with enough force to activate the ANSUL Fire Suppression System.
Manual pull station
After Fire Suppression System Discharge
WARNING
Electrical Shock Hazard
Keep water and other liquids from entering the inside of the equipment. Liquid inside the equipment could cause an electrical shock. Do not spray water or cleaning products. Liquid could contact the electrical components and cause a short circuit or an electrical shock.
CAUTION
Burn Hazard
Make certain all surfaces to be cleaned have cooled down to room temperature. Do not use water to clean any appliances that contain hot grease or cooking oils. Doing so may result in violent steaming and/or spattering.
After discharge, the Downdraft Vent Module will not operate until the ANSUL Fire Suppression System is serviced by an authorized ANSUL representative.
1. Immediately after discharge, call your authorized ANSUL representative to inspect and recharge the ANSUL Fire Suppression System.
NOTICE: The ANSUL Fire Suppression System must be serviced by
authorized ANSUL representative per ANSUL documentation, and in accordance with local code requirements and NFPA standards.
2. Clean the Downdraft Vent Module and surrounding area within 24 hours.
3. Wear rubber gloves during cleanup as sensitive skin may become irritated. If the ANSULEX agent or its residue comes in contact with skin or eyes, flush thoroughly with clean water.
4. Remove as much of the agent as possible using hot soapy water and sponges or clean rags. Dispose of sponges or rags in a local sanitary land fill site in accordance to local regulations.
5. After thoroughly cleaning all affected surfaces, adequately rinse with clean water. Dry with a soft cloth.
NOTICE: The Fire Suppression System agent is non-toxic.
However, food product and cooking grease/oil that has come in contact with the agent will no longer be suitable for human consumption and should be discarded.
2. When the ANSUL Fire Suppression System is manually activated, power to the cooking appliance and the entire Downdraft Vent Module will shut off.
Down Draft Vent Module with Induction Range(s) Operator’s Manual 7
Maintenance
System maintenance must be performed semi-annually by an authorized ANSUL distributor.
NOTICE: All ANSUL Fire Suppression System maintenance must be
performed by an authorized ANSUL representative, per ANSUL documentation, and in accordance with local code requirements and NFPA standards. Contact your local ANSUL representative for maintenance details.
INDUCTION RANGE OPERATION
For Your Safety
These precautions should be followed at all times. Failure to follow these precautions could result in injury to yourself and others.
To reduce risk of injury or damage to the unit:
• As a precaution, persons using a pacemaker should stand back 12" (30 cm) from an operating unit. Studies have shown that the induction element will not disrupt a pacemaker.
• Keep all credit cards, driver licenses and other items with a magnetic strip away from an operating unit. The unit’s magnetic field will damage the information on these strips.
• The heating surface is made of a strong, non-porous material. However, should it crack or break, stop using and immediately unplug the unit.
• Do not leave an empty pan on an operating unit.
• Do not touch the cooking surface. It remains hot after the unit is turned off.
• Do not place any objects inside the air intake or exhaust panels.
• Do not place weight on the control knob.
Overview
This equipment is intended for use in commercial food service operations only. It is not intended for household, industrial or laboratory use. It is intended to be used with induction-ready cookware.
Induction-Ready Cookware
• Flat base measuring 4¹⁄₂" (11.4 cm) to 10¼" (26 cm) wide
• Ferrous stainless steel
• Iron
• Cast iron
Features and Controls
F G
E
A On/Off Button. B Power/Temp Button. Press to toggle between power level (1-
100) and temperature control, and Fahrenheit and Celsius.
C Timer Button. Starts the timer. D Control Knob. Selects the temperature, power level or time,
depending on the mode.
E ºF and ºC LEDs. Illuminate to indicate which temperature is
displaying.
F Display Panel. Displays the power level, temperature, timer
time or an error code.
G Timer LED Light. Illuminates when timer function is operating.
°F
°C
POWER
TEMP
Timer
TIMER
A B C D
Unsuitable Cookware
• Cookware with a base less than 4¹⁄₂" (11.4 cm)
• Pottery, glass, aluminum, bronze or copper cookware
• Cookware with any type of footed base
8 Down Draft Vent Module with Induction Range(s) Operator’s Manual
INDUCTION RANGE OPERATION (CONTINUED) Operation
CAUTION
Burn Hazard
Do not touch hot food, liquid or heating surfaces while equipment is heating or operating.
NOTICE: Do not preheat empty cookware. Because of the speed and
efficiency of the induction range, cookware can very quickly overheat and be damaged.
NOTICE: Do not drop cooking utensils or other objects onto the
cooking surface. The strong, non-porous surface will
break. The warranty does not cover this type of abuse. NOTICE: Do not leave an empty pan on an operating unit. NOTICE: Do not heat sealed cans or containers as they may
explode.
Turn On the Induction Range
Press and release .
Adjust the Power Level or Temperature
Increase or decrease
Rotate the control knob.
• Clockwise increases the numbers.
• Counterclockwise decreases the numbers.
Cleaning
To maintain the appearance and increase the service life, clean your induction range daily.
WARNING
Electrical Shock Hazard
Do not spray water or cleaning products. Liquid could contact the electrical components and cause a short circuit or an electrical shock.
NOTICE: The cooking surface remains hot even when this equipment
is turned off.
NOTICE: Do not use abrasive materials, scratching cleansers or
scouring pads to clean the equipment. These can damage the finish.
1. Press and release .
2. Unplug the cord from the wall outlet.
3. Allow the equipment to cool.
4. Wipe the exterior with a clean damp cloth.
5. Thoroughly wipe off any mild soap or chemical cleaners.
Switch between power and temperature modes
POWER
Press and release .
TEMP
Switch between Fahrenheit and Celsius
POWER
Press and release two times.
TEMP
Cook Food
The display should remain constant during operation. If the display is flashing, see the Troubleshooting section in this manual.
Removing cookware from the cooking surface for more than ten minutes will cause the unit to automatically turn off. Removing cookware for less than ten minutes will not interrupt operation.
Use the Timer
1. Press and release . The timer LED will flash.
2. Rotate the control knob to set the time in full minutes (1-180).
3. When the timer cycle is complete, the range turn off.
4. To cancel the timer, press . The range will return to power or
temperature mode.
TIMER
TIMER
Turn off the Induction Range
1. Press and release .
2. The control panel will display HOT until the surface has cooled.
Down Draft Vent Module with Induction Range(s) Operator’s Manual 9
INDUCTION RANGE OPERATION (CONTINUED)
Troubleshooting
Problem Might be Caused By Course of Action
There is not a pot/pan on the induction
The unit turned off after 10 minute(s).
The unit is on, but not heating.
The digital display is flashing F2.
The unit suddenly stopped working.
range or the pot/pan is not induction­ready cookware. The induction range turned off. This is normal.
The cookware may be too small or may not be induction-ready.
The overheat-protection feature may have activated.
The unit may be too close to an external heat source or the air intake may be restricted.
Make sure the pot/pan is induction ready. See “Overview” on page 8.
Make sure the pot/pan is induction ready. See “Overview” on page 8.
Remove cookware. Let cooking surface cool.
Relocate the unit away from any external heat source. Clear any obstructions to the air intake.
FCC Statement
This equipment has been tested and found to comply with Part 18 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for help
To assure continued compliance, any changes or modifications not expressly approved by the party Responsible for compliance could void the user’s authority to operate this equipment.
10 Down Draft Vent Module with Induction Range(s) Operator’s Manual
This page intentionally left blank.
Down Draft Vent Module with Induction Range(s) Operator’s Manual 11
Loading...
+ 25 hidden pages