Project:
The Vollrath Company, L.L.C.
1236 North 18th Street
Sheboygan, WI 53081-3201 U.S.A.
Customer Service: 800.628.0830
Canada Customer Service: 800.695.8560
Main Fax: 800.752.5620 or 920.459.6573
Technical Services: 800.628.0832
Technical Services Fax: 920.459.5462
Item Number:
Quantity:
MODULAR DROP-IN: HOT/COLD TOP AND BOTTOM MOUNT WELLS
MODELS
3667101D Single Pan Drop-in, Top Mount, 120V
3667102D Single Pan Drop-in, Top Mount, 120/208-240V
3667101U Single Pan Drop-in, Bottom Mount, 120V
3667102U Single Pan Drop-in, Bottom Mount, 120/208-240V
FEATURES
❑ Top is 18-gauge 300 series stainless steel, with a flat work
surface around the opening and die stamped with fullperimeter drip edge. A molded breaker gasket is fitted
under the drip edge.
❑ Seamless well is 18-gauge 300 series stainless steel
Modular Drop-In: Hot/Cold Top-Mount Well
DESCRIPTION
The modular drop-in can operate either hot or cold and is
available in both top-mount and bottom-mount configurations.
In cold operation, the well meets NSF7 standards. In hot
operation, the well meets NSF4 when using moist heat.
A full-perimeter drip edge contains spills and condensation
within the stainless steel countertop area of the drop-in.
High-density polyurethane foam insulation surrounds the
exterior of the well to provide most efficient performance with
energy savings.
A 3" (7.62 cm) recess lowers the food pan below the work
surface to minimize the impact of ambient air.
Modular drop-in orders cannot be canceled or returned.
❑ Exterior housing is 18-gauge galvanized steel
❑ Refrigeration coils surround the exterior side walls of the
well for maximum cooling
❑ 625 Watt rope heater is attached to the bottom of well
❑ The inner well assembly is insulated with foamed-in-place
polyurethane foam insulation
❑ Hot/Cold operation toggle switch with lighted indicator
❑ On/Off switch is mounted on side the control box
❑ Thermostatic hot control
❑ Factory set cold control on compressor
❑ Condensing unit suspended below well
❑ ¾" (1.9 cm) integral drain is standard
❑ Unit comes with cord and plug and does not require hard
wiring
❑ Positioning clips are provided to center drop-in within the
cutout
❑ For complete air circulation, two openings in the cabinet
are required. Louver cutout size is 8" x 10"
(20.3 cm x 25.4 cm).
❑ One year parts and labor warranty. Additional four years on
compressor
Modular Drop-in: Hot/Cold Top and Bottom Mount Wells
The Vollrath Company, L.L.C.
Due to continued product improvement, please consult
www.vollrathco.com for current product specifications.
WARRANTY: All models shown come with Vollrath’s standard
warranty against defects in materials and workmanship. For full
warranty details, please refer to the Vollrath Equipment and Smallwares Catalog.
Approvals Date
The Vollrath Company, L.L.C.
1236 North 18th Street
Sheboygan, WI 53081-3201 U.S.A.
Customer Service: 800.628.0830
Canada Customer Service: 800.695.8560
Main Fax: 800.752.5620 or 920.459.6573
Technical Services: 800.628.0832
Technical Services Fax: 920.459.5462
Top Mo u n t
Bottom Mount
Front View Side ViewTop View
13¼ (33.7)
Inside Upper
Front View Side ViewTop V i e w
11⁷⁄₈ (30.2)
Inside
Lower
22 (55.9)
Inside Upper
19⁷⁄₈ (50.5)
Inside
Lower
16⁷⁄₈ (52.9)
Overall
Flange
14½
(36.8)
25¹⁄₈ (63.8)
Overall
Flange
11¹¹⁄₁₆
(29.7)
24¹⁄₁₆
(61.1)
23⁷⁄₈
(60.6)
13¼ (33.7)
Inside Upper
11⁷⁄₈ (30.2)
Inside
Lower
22 (55.9)
Inside Upper
19⁷⁄₈ (50.5)
Inside
Lower
18¹⁄₁₆ (45.9)
Overall
Flange
17⁵⁄₁₆ (44)
Cutout
Opening
14½
(36.8)
26 (66)
Overall
Flange
25¼ (66.1)
Cutout
Opening
³⁄₈ (1)
Rise above
countertop
10½
(267)
23⁷⁄₈
(60.6)
¾ (1.9)
Minimum
Space
Required
¾ (1.9)
Minimum
Space
Required
6½ (16.5)
Inner Well
6½ (16.5)
Inner Well
NOTE: Vollrath drop-ins are made to order and cannot be returned. It is the responsibility of the installer to ensure
cut-outs on new installations are correct, or retrofit installation dimensions match up with Vollrath product dimensions.
Vollrath will not guarantee that our models retrofit with specific competitive models (as competitive specifications can
change without notice). We recommend countertop cut-outs be made after receipt of the Vollrath drop-in, to ensure
proper fit prior to cutting into countertop materials.
23⁷⁄₈
(60.6)
5-15R
120V
14-20R
120/208-240V
Modular Drop-in: Hot/Cold Top and Bottom Mount Wells
MODULAR DROP-IN: HOT/COLD TOP AND BOTTOM MOUNT WELLS
MODELS
3667101D Top Mount, 120V 3667101U Bottom Mount, 120V
3667102D Top Mount, 120/208-240V 3667102U Bottom Mount, 120/208-240V
DIMENSIONS
❑ Dimensions shown in inches (cm)
❑ Well cutout must have a
⁷⁄₈" (2.22 cm) corner radius
❑ Control cutout: 8
³⁄₈" (9.5 mm) corner radius
³⁄₈" x 7¹⁄₈" (21.3 x 21.3 cm) with a
The Vollrath Company, L.L.C.
ELECTRICAL SPECIFICATIONS
Item Voltage
3667101D 120 5 5.2 5-15P
3667102D 120/208-240V 5 2.3 - 2.6 14-20P
3667101U 120 5 5.2 5-15P
3667102U 120/208-240V 5 2.3 - 2.6 14-20P
Amps
PlugRefrigeration Mode HeatIng Mode
©
2012 The Vollrath Company L.L.C. Form Number L35823 2/12
Receptacles
Y
W
X
Printed in USA