Vivotek KA-SD10 Instruction Manual

Page 1
MINI SPEED DOME CAMERA
10X Mini Speed Dome Camera
Instruction Manual
Rev 1.05 dated on August 15st, 2007
Page 2
CONTENTS
5
3 4
3
Warnings & Caution What’s in the Box? General Features Names of Each Part Installation
A. Connections
B. Ceiling Mount Type
C. Embedded Mount Type
D. Pipe Mount Type
E. Gooseneck Mount Type
F. Wall Mount Type
G. Corner Mount Type
H. Pole Mount Type
Quick Operating Keys Diagnostic OSD Menu Setting
A. OSD Menu Table
B. DOME SET
C. CAMERA SET
D. PRESET
E. AUTO SCAN SET
F. TOUR SET
G. PRIVACY SET
H. PATTERN SET
I. ALARM SET
J. SECTOR SET
DIP Switch Setting
A. Factory Default setting B. ID Setting (1-ON,0-OFF)(1->10) C. Protocol Setting D. Baud Rate Setting E. 485 Terminations
Trouble Shooting Specification Dimension
29 30 31 32 33 34 35 36 36 36 37 37 37 38 39 40
27
22
21
21
20
17 18
15
13
6 7 8 10 12
2
Page 3
WARNINGS & CAUTION
If you fail to read this information and handle the product incorrectly, death or serious injury may occur.
1. Camera
2. Screws ( Ø4x16 screw 5EA )
3. Screws ( Ø3.5x30 screw 3EA )
4. Terminal block (5pin 2EA)
5. Manual
6. Screw Cap (1 EA)
7. Wrench
8. Safety Wire
The unit should be installed by the trained
personnel
Switch off immediately if the product emits
smoke or abnormal heat.
This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
This symbol is intended to alert the user to the presence of un-insulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Never install the product in area exposed to
water, oil or gas.
Never install the product on a ceiling that
cannot hold its weight.
Never touch the power cord with wet hands.
Clean only with dry cloth.
Never install the product in extreme high or
low temperature.
Ensure that the product is not subjected to
strong impacts and vibration
Warning
Never manually move the pan/tilt assembly. Serious and permanent damage will occur
What’s in the Box ?
Never expose the camera to direct sunlight
Never touch the front glass of the product.
3
Page 4
GENERAL FEATURES
100X Zoom Mini Speed Dome
10X Optical Zoom with 10X digital zoom
±0.02° dome system accuracy with full micro step
With 0.1° positional accuracy, the camera provides excellent sensitive and delicate control. This is achieved by full micro step motors and twin gear system
360° Endless Rotation
10X mini speed dome is capable of endless rotation of 360 degrees
Compensation function: preset position
The function provides absolute preset position even in difficult applications where vibration and strong winds may otherwise affect dome performance.
Over 200°/Sec Preset Speed
The 360° full pan function moves through a maximum of 200°/sec., enabling you to quickly pinpoint the spot you want to watch. Tilt speed is also driven at 200°/sec on preset seek.
Polarity Protection of Power (DC12V)
This protection function prevents damage to the domes power board if the dc supply is connected with incorrect polarity.
Filter changeable True Day/Night
Top quality images are assured under day and night conditions due to the true day / night camera with IR cut filter. Low light sensitivity is further increased by the cameras digital slow shutter.
Indoor / Outdoor applications
The domes small size and construction to IP 66 ingress protection rating make it ideal for internal or external applications.
Quick Operation Keys
This camera provides quick function keys to allow control by most keyboards and DVRs that have Pelco protocol support.
Various Surveillance Functions
Auto Scan repeats pan and tilt between two preset
positions with different speed and dwell time.
8 Group Tour up to 8 Programmable Group tours are
available with each group is consisting of up to 60 preset steps with different speed and dwell times along with 16 character titling.
165 Preset positions up to 165 programmable
preset positions are available with 16 character title.
8 Patterns up to 8 programmable user-defined patters
are available with 16 character title. Each can be up to 50 seconds long, giving a total of 400
seconds.
8 Sectors up to 8 programmable user-defined sectors
are available with 16 character titling.
4 Privacy Masking Zones up to 4 programmable
user-defined privacy masking zones are available.
4 Alarm input up to 4 alarms can be wired to the
dome head and can activate presets, tours, or patterns.
150°/S – Manual speed
The dome provides up to 150°/sec of manual speed and is also adjustable from 100°/sec to 150°/sec in 10°/sec increments.
1/4” Sony Super HAD CCD
Equipped with Sony Super HAD CCD technology, the camera provides excellent sensitivity and low smear levels.
Intelligent Pan/Tilt Controlling
Intelligent Pan/Tilt function is continually increases or decreases pan and tilt speeds in proportion to zoom.
Dome Housing
The elegantly designed aluminum body and Poly Carbonate dome cover provide a very solid product for a wide range of applications. .
Password Protection
It is possible to password protect all dome settings to prevent unauthorized changes.
4
Page 5
NAMES OF EACH PAR T
4. Terminal Block
5. Main body
1. Surface Mount Adaptor
2. Cap Screw ( PT3/4 , 1EA )
3. Dip Switch
5
Page 6
INSTALLATION
A. CONNECTIONS
A-1
1. Loose the screws on the domes cover and remove it from the base.
(Screws won’t be removed)
2. Loosen the screws which connect mount cover and Main base and separate dome cover from the main base. (These are captive screws that do not remove)
3. Connect power to Power and GND.
4. Connect video to video and GND.
5. Connect communication cable to RS-485 connectors.
6. Connect alarm common cables to GND. Connect the alarm input cables to their relevant terminal (1-4) Alarm polarity can be programmed as N/O or N/C
z Do not over tighten screws. This can cause damage.
- 12VDC type
- 24VAC type
FIG.2
6
Page 7
B. CEILING MOUNT TYPE
FIG.4
FIG.3
1. Fix the surface mount adaptor with 4pcs of screws on the place where you want to
install. (FIG.3)
2. When you use pipe, please note the standard size of pipe. (FIG.4)
3. Re-assemble the dome.
FIG.5
7
Page 8
C. EMBEDDED MOUNT TYPE
,
FIG.6 FIG.7
FIG.8
1. Make a hole, 190mm, on the ceiling. (FIG.6)
DECORATION COVER
CAMERA
M3.0 SCREW
HOLDER
LOCK LEVER
LOCK LEVER
LOCK LEVER
SAFETY WIRE HOLE
SUSPENSION
LOCK LEVER
Embedded mount bracket 1ea ► Holder 3ea
Decoration cover 1ea Safety wire 1ea
Contents
Screw – M3.0 x 6 5ea Screw - ø4.0 x 16 1ea
8
Page 9
2. Fold the lock levers and insert the bracket into the hole.
You can fix the lock lever by driving screws. (FIG.7)
3. Fix the decoration cover on the rear of camera by holder screws (M3.0) (FIG.8)
4. Hook the safety wire on the suspension and connect it to camera (FIG.9)
5. Install the camera by inserting cover lock and twisting it clockwise. (FIG.10)
6. Fix the decoration cover by screw (Ø4.0x16) (FIG.10)
FIG.9
FIG.10
9
Page 10
D. PIPE MOUNT TYPE
Contents
Pipe mount bracket 1ea ► Rubber 1ea
Screw – M4.0 x 8 4ea Set anchor bolt (W5/16) 4ea
SCREW M4x8 (4ea)
BRACKET
(RUBBER BOTTOM VIEW)
RUBBER
BOTTOM COVER
FIG.11
1. As above FIG.11, assemble rubber and bracket on the bottom of camera.
2. After finishing assembly, it will be shown as below. (FIG.12)
FIG.12
3. If you want to install the speed dome on the concrete wall, you need to make 12.5mm
10
Page 11
diameter 4 holes by drill like FIG. 13 (Depth 37mm)
4. Install SET ANCHOR BOLT on the holes.
5. As shown on FIG.14, after assembling mini PTZ and bottom cover assembly, drive the
pipe mount bracket and fix. (FIG.14)
FIG.13
FIG.2)
FIG.14
11
Page 12
E.GOOSENECK MOUNT TYPE
Contents
Gooseneck mount bracket 1ea ► Rubber 1ea
Set anchor bolt (W5/16) 4ea ► Screw M4x8 4ea
FIG.15
1. If you want to install the speed dome on the concrete wall, you need to make 12.5mm
diameter 4 holes by drill like FIG.15 (Depth 37mm)
2. Install SET ANCHOR BOLT on the holes.
3. As shown on FIG.16, after assembling mini PTZ and bottom cover assembly, drive the
gooseneck mount bracket and fix. (FIG.16)
FIG.16
12
Page 13
F.WA L L MOU NT TY PE
Contents
Wall mount bracket 1ea ► Set Anchor Bolt (W5/16) 4ea
1. If you want to install the speed dome on the concrete wall, you need to make 12.5mm
diameter 4 holes by drill like FIG. 1 ( Depth 37mm) (FIG.17)
2. Install SET ANCHOR BOLT on the holes.
3. To install Wall Mount Bracket
Tip> Select a ceiling board strong enough to hold 4 times the total weight of the camera
(Weight combined camera: approx.5kg)
FIG.17
<the cable into the ceiling> <the cable out of the ceiling>
FIG.18
13
Page 14
4. Assemble a wall mount bracket and camera by Hexagon socket head cap screws
(M4.0X16) (FIG.19)
HEXAGON SOCKET HEAD CAP SCREW M4.0x16 4EA
FIG.19
14
Page 15
G.CORNER MOUNT TYPE
Contents
Corner mount adaptor 1ea Set Anchor Bolt (W5/16) 4ea M10 Bolt & Nut 4ea
1. First mark the positions of holes placing the corner mount bracket. (FIG.20)
2. Make 12.5mm diameter 4 holes by drill. (Depth 37mm)
3. Install SET ANCHOR BOLT on the holes.
4. Fix the wanted bracket on the corner mount bracket with 4 ea of M10 BOLT before you
install the corner mount bracket. (FIG.21)
5. Screw the set anchor bolt of the bracket by nut on the wall. (FIG.22)
FIG.20
FIG.22 FIG.21
6. After driving a bottom cover assembly to gooseneck mount bracket, as shown on FIG23,
15
Page 16
assemble mini PTZ with bottom cover assembly. (FIG.23)
FIG.23
16
Page 17
H.POLE MOUNT TYPE
1. Fix the wanted bracket on the pole mount bracket with 4 ea of M10 BOLT before you install
the pole mount bracket. (FIG.24)
2. Tie the bracket with SUS BAND tightly. (FIG.25)
3. As shown FIG.26 after installing a wall mount bracket, fix a camera on the wall mount bracket.
(FIG.26)
FIG.24
FIG.25
FIG.26
HEXAGON SOCKET HEAD CAP SCREW M4.0x16 4EA
Contents
Pole mount adaptor 1ea Band Clamp 2ea M10 Bolt & Nut 4ea
17
Page 18
The dome supports Pelco D and Pelco P protocols.
The dome may be used with any controller or DVR etc that supports the Pelco D and Pelco P protocols.
The default setting of the dome is Pelco D / P (auto detection) with 2400 bps (baud rate).
[PELCO D/P, SAMSUNG PROTOCOLS]
The comprehensive feature set of the dome is available from Pelco compatible controllers via quick
operation keys as defined below.
1-64 + preset and 100~200 + preset are used for normal user presets. Presets 65-99 + are
reserved for special functions.
For example, to enter OSD MENU, press the button 95 +PRESET
<Quick Operation Key Table 1, Pelco D/P, SAMSUNG>
Number Note Function
1 ~ 64, 100~200 +Preset PRESET Execute Preset 1 ~ 64 65 + Preset PRESET STATUS Display Preset Status 66 +Preset AUTO SCAN Execute Auto Scan 67 +Preset AUTO FLIP Selectable On/Off/Auto in Auto Flip function 71~78 +Preset GROUP TOUR Execute Group Tour #1 ~ #8 81~88 +Preset PATTERN Execute Pattern #1 ~ #8 91 + Preset ZERO POSITION Search For Pan / Tilt Zero Position 92 + Preset FREEZE Select Freezing of current image 93 + Preset BLC MODE Selectable On/Off in BLC function 94 + Preset D/N MODE Selectable Day/Night Mode (Auto/Day/Night Mode) 95 + Preset OSD MAIN MENU To enter OSD Main Menu 96 + Preset FOCUS ADJUST Focus adjustment 97 +Preset ALARM Selectable Enable/Disable all Alarms
<Quick Operation Keys Table 2> Use these function keys if controller has these keys>
z 65 + preset:” Status Report” is displayed, to remove this screen, press Focus Near button.
z 92 + preset: This feature freezes the current live image during tour, auto scan or pattern
operation. When you press 92 + preset button, the image freezes but the camera is still
working as per operation such as tour, pattern or auto scan. To return to normal images,
press 92 + preset button again. This feature is operated by preset number but not included
in OSD main menu.
z If a controller asks for an unsupported feature “Not available” is displayed on the monitor.
Menu Function
Tilt Up / Down Sub menu cursor moves up / down Pan Left / Right Enter to the sub menu or status change or decrement Focus Near Using for Enter key when user select YES or NO Focus Far Using for function changing keys when set coordinate Zoom Tele Status cursor to the right Zoom Wide Status cursor to the left
QUICK OPERATING KEYS
18
Page 19
[VICON PROTOCOL]
If user wants to choose Vicon Protocol, the user may change the dip switch first.
(Refer to Page #36 DIP SWITCH SETTING - PROTOCOL) Baud Rate: 4800 (Vicon default)
The operation system is almost same as Pelco D/P protocols but some special features are different way as
noted below’
<Quick Operation Key Table 2: VICON>
Number Note Function
1 ~ 79 +Preset PRESET Execute Preset 1 ~ 79 80~87 +Preset GROUP TOUR Execute Group Tour #1 ~ #8 88~89 +Preset PATTERN Execute Pattern #1 ~ #2 90 + Preset Focus Mode Set Focus Mode Toggle to Auto or Manual
90 + Preset Save Pan/Tilt Lockout PAN/TILT Lock or Unlock setting 91 + Preset Save ZERO POSITION Search For Pan / Tilt Zero Position 92 + Preset Save ALARM Selectable Enable/Disable all Alarms 93 + Preset Save BLC MODE Selectable On/Off in BLC function 94 + Preset Save OSD MAIN MENU To enter OSD Main Menu 95 + Preset Save D/N MODE Selectable Day/Night Mode (Auto/Day/Night Mode) 96 + Preset Save SECTOR SECTOR setting menu entrance 97 + Preset Save DOME Reset Initial DOME Reset - Rebooting 98 + Preset Save AUTO PAN AUTO PAN setting menu entrance 99 + Preset Save Pan/Tilt Speed Manual Pan/Tilt Max Speed setting
<Quick Operation Keys Table 2> Use these function keys if controller has these keys>
Menu Function
Tilt Up / Down Sub menu cursor moves up / down Pan Left / Right Enter to the sub menu or status change or decrement Focus Near Using for Enter key when user select YES or NO Focus Far Using for function changing keys when set coordinate Zoom Tele Status cursor to the right Zoom Wide Status cursor to the left
QUICK OPERATING KEYS
19
Page 20
DIAGNOSTIC
Whenever the dome is powered on, a standard diagnostic is operated.
The following messages are displayed on the monitor.
PAN ORIGIN TEST OK TILT ORIGIN TEST OK TX CONNECTION TEST OK CAMERA COMM TEST OK
WAITING………
CAMERA ID : 001
BAUD RATE : 2400 BPS
A. Pan Origin Test
Zero point of Pan is located during the Panning test.
B. Tilt Origin Test
Zero point of Tilt is located during the Tilt test.
C. TX connection Test
The Tx connection test looks for commands from a controller to the dome. If no commands are detected
the test will exit after 60 seconds.
During the 60 seconds, the camera must receive a signal from the controller or DVR, so please operate
the controller during this phase. As soon as the dome detects a command “OK” will be displayed and the
test will move on to the next step.
If the Tx connection test fails check the RS 485 wiring.
D. Camera Comm. Test
Camera communication is also checked.
OK should be displayed in these four tests before installation.
If all the above Tests are OK, “NOW EEPROM CHECKING” and “ALL DATA INITIALIZING” is displayed
and the camera is ready to operate.
20
Page 21
OSD MENU SETTING
A. OSD MENU TABLE
MAIN MENU
DOME SETUP
CAMERA SET
AUTO SCAN
TOUR
PRAVACY
PATTERN
ALARM
SECTOR
EXIT
DOME SET
CAMERA ID : CAM1□□□□□□□□□□□□
RECOVER : OFF
MANUAL SPEED : 100°/ S
AUTO FLIP : OFF
ZOOM SPEED : FAST
ALARM : DISABLE
LANGUAGE : ENGLISH
[NEXT PAGE]
SAVE AND EXIT
EXIT
CAMERA SET
FLICKER : OFF/ON
MIRROR : OFF/ON
D ZOOM : OFF/ON
WB MODE : AWB MODE
PIC FLIP : OFF/ON
BLC : OFF/ON
D/N MODE : AUTO
DSS MODE : OFF/ON
EXIT
PRESET SET
PRESET NO: 001
PRESET ID: PRESET01□□□□□□□□□
PAN:XXX.X.XX.X TILT:XXX.X.XX.X
SAVE
EXIT
AUTO SCAN SET
START ANGLE : XXX.X.XX.X
END ANGLE : XXX.X.XX.X
DIRECTION : CW
ENDLESS : OFF/ON
SPEED : QUICK
DWELL TIME : 03
SAVE AND EXIT
EXIT
SECTOR SET
SECTOR NO : 01
SECTOR ID : SECTOR01□□□
SECTOR START: XXX.X.XX.X
SECTOR END : XXX.X.XX.X
SAVE
EXIT
PATTERN SET
PATT NO. : 01
PATT TITLE PATTERN01□□□
DATA FILL : 100%
SAVE
EXIT
ALARM SET
ALARM NO. : 01
ALARM INPUT : OFF
ALARM ACT : 01
SAVE
EXIT
PRIVACY SET
PRIVACY NO. : 01
DISPLAY
ACTION
SAVE
EXIT
TOUR SET
TOUR NO. : 01
TOUR TITLE : TOUR01□□□□□□
TOUR STEP : 01
PRESET NO : 01
DWELL TIME : 10
SPEED : 200°/S
SAVE AND EXIT
EXIT
NEXT PAGE
[OSD DISPLY]
[SYSTEM STATUS]
[INITIALIZATION]
[PREVIOUS PAGE]
[INITIALIZATION]
[TOUR CLEAR]
[PRESET CLEAR]
[SECTOR CLEAR]
[PRIVACY CLEAR]
[PATTERN CLEAR]
[LOAD OPTIMIZED DEFAULT
[SYSTEM STATUS]
PROTOCOL : PELCO D,P
BAUD RATE: 2400BPS
FIRMWARE VER.:2.00
UPGRADED DATE: 06.28,06
CAMERA MODULE: SDM100
[PREVIOUS PAGE]
OSD DISPLAY
CAMERA ID: OFF/ON
PRESET ID: OFF/ON
SECTOR ID: OFF ON
COORDINATE:ON/OFF
[PREVIOUS PAGE]
21
Page 22
OSD MENU SETTING
To enter OSD Menu, press the button 95 + PRESET.
* Use “up down” to move the position and “left right” to make selection
B. Dome Setup
In order to enter Dome setup, select right direction when the cursor is on dome setup.
MAIN MENU
DOME SETUP CAMERA SET AUTO SCAN TOUR PRIVICY PATTERN ALARM SECTOR EXIT
DOME SET
CAMERA ID : CAM1 RECOVER : OFF MANUAL SPEED : 100°/S AUTO FLIP : OFF ZOOM SPEED : FAST ALARM : DISABLE LANGUAGE : ENGLISH [NEXT PAGE] SAVE AND EXIT EXIT
DEFAULT SETTING
B-1. DOME SET - CAMERA ID
To set camera name, and select a title of up to 16 characters using left or right direction keys or
joystick.
Press ZOOM TELE button to move to the next character from left to right direction and
ZOOM WIDE button to move to the next character from right to left direction
(Space displays when appears)
22
Page 23
OS D MENU SETTING
B-2. DOME SET - RECOVER
This feature allows the dome to revert to a specific programmed action when the dome has not
received a command for the recovery timer period.
Actions can be Auto scan, group tour and pattern. The recover time can be programmed from 15
second to 99 seconds. The default setting is OFF.
B-3. DOME SET - MANUAL SPEED
The manual speed of Pan/Tilt is selectable from 100°/sec up to 150°/sec. The default setting is
100°/sec
B-4. DOME SET - AUTO FLIP
Auto Flip enables the dome to automatically do a 180° turn when the tilt bottom point is reached.
The default setting is OFF. This function can be recalled by pushing 67+ preset button.
B-5. DOME SET – ZOOM SPEED
Zoom speeds are selectable as FAST or SLOW mode. The default setting is FAST.
B-6. DOME SET – ALARM
You must enable the alarms for them to operate. The default setting is DISABLED. This function
can be recalled by pushing 97 + preset button.
B-7. DOME SET - LANGUAGE
Multiple languages are selectable (English, Italian, German, Dutch, Danish, Polish and French)
The default setting is ENGLISH.
B-8. DOME SET – [NEXT PAGE]
DOME SET
SYSTEM LOCK: : OFF [PASS WORD] [OSD DISPLAY] [SYSTEM STATUS] [INITIALIZATION] [PREVIOUS PAGE]
DEFAULT SETTING
B-8-1. DOME SET – [NEXT PAGE] – SYSTEM LOCK
All stored dome settings can be password protected to prevent unauthorized changes. In order to
enter [PASS WORD] page, the system lock status must firstly be set as ON.
The default setting is OFF.
23
Page 24
OSD MENU SETTING
B-8-2. DOME SET – [NEXT PAGE] – [PASSWORD]
To enter this page to set a password, move joystick or pan key in the right direction. The password
must be set by preset number from 001 to 255
(Default 99)
A. OSD MAIN MENU TABLE (PAGE 14) default setting is BLANK.
Enter any number from 001~255 on the password blank area and again for confirmation on blank
area. Then “CONFIRMED” is displayed on the monitor and the menu will go back to the previous
page automatically.
ENTER PASSWORD
BY ENTERING PRESET CODE PASSWORD *** CONFIRM ***
ENTER PASSWORD
BY ENTERING PRESET CODE PASSWORD *** CONFIRM ***CANCELLED
ENTER PASSWORD
BY ENTERING PRESET CODE PASSWORD *** CONFIRM ***CONFIRMED
<CONFIRMED> <CANCELLED>
If you press an incorrect number between PASSWORD and CONFIRM, “CANCELLED” is
displayed on the monitor and the menu will return to the previous page automatically after 3
attempts.
* When a password has been set, the operator must enter the correct password in order to enter
OSD MAIN MENU, or to change any of the domes configuration data
* If you set a password you must ensure that it does not get lost. If this happens the dome must be
returned for workshop repair
24
Page 25
OSD MENU SETTING
B-8-3. DOME SET – [NEXT PAGE] – [OSD DISPLAY]
The camera ID setting defines whether the camera OSD display is displayed or switched off.
B-8-4. DOME SET – [NEXT PAGE] – [SYSTEM STATUS]
OSD DISPLAY
CAMERA ID : OFF PRESET ID : OFF SECTOR ID : OFF COORDINATE : ON [PREVIOUS PAGE]
DEFAULT SETTING
This page shows the information of this camera.
- Protocol and baud rate are shown according to the dip switch setting
(Refer to page 29, 30 and 31)
- Firmware version and upgraded date will be changed if the dome has been upgraded.
- The camera module type is stated as follows.
SDM100 : SAMSUNG 10X ZOOM CAMERA MODULE.
B-8-5. DOME SET – [NEXT PAGE] – [INITIALIZATION]
To clear the current settings select the item that you wish to reset back to factory defaults.
SYSTEM STATUS
PROTOCOL : PELCO D, P BAUD RATE : 2400 BPS FIRMWARE VER. : X.XX UPGRADED DATE : YY.MM.DD CAMERA MODULE : XXXXXXXX [PREVIOUS PAGE]
INITIALIZATION
[TOUR CLEAR] [PRESET CLEAR] [SECTOR CLEAR] [PRIVACY CLEAR] [PATTERN CLEAR] [LOAD OPTIMIZED DEFAULT] [PREVIOUS PAGE]
DEFAULT SETTING
25
Page 26
OSD MENU SETTING
- To clear the memorized data, move the joystick or pan right key until the cursor is on the
required item.
TOUR CLEAR
ARE YOU SURE? YES NO
TOUR CLEAR
Press FOCUS NEAR button when the cursor is at YES in order to clear memorized data. Then
each item such as tour, preset, and sector will flicker for about 2~3 seconds. After this process,
the menu is returned to the previous page.
* Use the above method for [PRESET CLEAR], [SECTOR CLEAR], [PRIVACY CLEAR], [PATTERN
CLEAR], [TOUR CLEAR].
LOAD OPTIMIZED DEFAULT
ARE YOU SURE? YES NO
ALL DATA INITIALIZING
- To clear all data and return to factory defaults, move the joystick right or press the pan right key to
when the cursor is at [LOAD OPTIMIZED DEFAULT] to enter the next page.
- Move joystick or the pan right keys so that the cursor is over YES, then press the FOCUS NEAR
button.
“ALL DATA INITIALIZING” is then displayed for about 5~7 seconds and then the menu is returned
to the previous page automatically.
B-9. DOME SET – [NEXT PAGE] – SAVE AND EXIT
To save the memorized data and escape this page, move the joystick right or press the
pan right key when cursor is at SAVE AND EXIT.
B-10. DOME SET – [NEXT PAGE] – EXIT
In order to escape this page, move the joystick right or press the pan right key when the
cursor is at EXIT
26
Page 27
OSD MENU SETTING
C. CAMERA SET
CAMERA SET
FLICKER : OFF MIRROR : OFF APERTURE : 10 D ZOOM : OFF WB MODE : AWB MODE PIC FLIP : OFF BLC : OFF D/N MODE : AUTO DSS MODE : OFF EXIT
DEFAULT SETTING
C-1. CAMERA SET - FLICKERLESS
The flicker less feature has options of 50Hz and 60Hz. The default setting is OFF (NTSC: 60Hz /
PAL: 50Hz). The flicker less mode only needs to be set when there is a mismatch between the
power frequency and camera sync rate. The default setting is OFF
C-2. CAMERA SET - MIRROR
This feature literally swaps the image left and right as if looking into a mirror. The default setting is
OFF.
C-3. CAMERA SET – APERTURE
Aperture correction enhances the picture details and sharpness by increasing the gain of the
caemra. Increade the value to sharpen the image, decrease to soften it The default seeting is 10.
(the aperture level is from 01 ~ 15)
C-4. CAMERA SET – D ZOOM
If neabled digital zoom is applied when the zoom lens has reached its maximum optical zoom in
capability The default setting is OFF.
C-5. CAMERA SET – WB MODE
White balance functions has 4 modes and may need to be changed depending on the situation.
z AWB Mode – 3,200°K to 6, 000°K (Default)
z Indoor – up to 3,200°K z Outdoor – up to 5,800°K z ATW Mode - 2,000°K to 10, 000°K
27
Page 28
OSD MENU SETTING
C-6. CAMERA SET – PIC FLIP
The picture flip feature swps the top and bottom of the image, literally inverting it.. The default
setting is OFF.
C-7. CAMERA SET – BLC (Back Light Compensation)
The default setting is OFF and BLC modes can be OFF/ON.
OFF – Backlight compensation is not activated.
ON – Back light compensation is activated.
This function can be recalled by pushing 93 + preset button.
C-8. CAMERA SET – D/N MODE
The dome camera can operate in day /night mode and will switch depending on lighting conditions.
Alternatively it can be forced into color only mode.
The default setting is AUTO MODE. This function can be recalled by pushing 94 + preset button.
C-9. CAMERA SET – DSS MODE (DIGITAL SLOW SHUTTER)
If digital slow shutter is enabled the exposure time of the camera is increased, this allowing more
light to be collected and improving low light response. This setting should not be enabled if the
dome is touring at night or fast moving objects are likely to be in the scene as smearing is also
increased.
The default setting is OFF.
C-10. CAMERA SET – EXIT
To escape this page, move the joystick right or press the pan right key.
28
Page 29
OSD MENU SETTING
D. PRESET SET
To enter PRESET SET, move joystick to the right direction.
PRESET SET
PRESET NO :001 PRESET ID :PRESET001------­PAN :XXX.XX TILT : XXX.XX SAVE EXIT
DEFAULT SETTING
D-1. PRESET – PRESET NO.
Up to 165 preset positions are available. Use the joystick or pan left/right keys to select the number.
D-2. PRESET – PRESET ID
To create preset titles use the joystick or pan left/right keys to navigate the menu.
The ZOOM TELE button moves to the next character from left to right and ZOOM WIDE button
moves to the next character from right to left
(Space displays when
appears)
D-3. PRESET – PAN: XXX.X TILT: XX.X
Press FOCUS FAR button in order to set preset position then, use the joystick or pan left/right keys
to the position where memorized preset number .is needed. Then press FOCUS FAR button again
after setting a preset location.
D-4. PRESET – SAVE
Move the joystick right or press the pan right key when the cursor is at SAVE and then the cursor
will be located on Preset ID for the continuous preset No. setting.
D-5. PRESET – EXIT
To escape this page, move the joystick right or press the pan right button.
29
Page 30
OSD MENU SETTING
E. AUTO SCAN SET
* 66 + preset button is working as AUTO SCAN after setting.
AUTO SCAN SET
START ANGLE : XXX.X.XX.X END ANGLE : XXX.X.XX.X DIRECTION : CW ENDLESS : OFF SPEED : 10°/S DWELL TIME : 03 SAVE AND EXIT EXIT
DEFAULT SETTING
E-1. AUTO SCAN – START ANGLE
To set the start position, press FOCUS FAR button then move the dome to the required start position.
Press FOCUS FAR button again is to escape.
E-2. AUTO SCAN – END ANGLE
To set the end position, press FOCUS FAR button then move the dome to the required end position.
Press FOCUS FAR button again is to escape.
E-3. AUTO SCAN – DIRECTION
Auto Scan directions are available as CW or CCW.
CW: Clock wise direction (Default)
CCW: Count Clock Wise Direction.
E-4. AUTO SCAN – ENDLESS
Auto Scan can be set to endless rotation by enabling the endless option. The default setting is OFF.
E-5. AUTO SCAN – SPEED
Auto scan speed can be programmed from 05°/S up to 35°/S. The default setting is 10°/S.
E-6. AUTO SCAN – DWELL TIME
The dwell time at the start and end points can be programmed from 1 second to 30 seconds. The
default setting is 03 seconds.
E-7. AUTO SCAN – SAVE AND EXIT
To save the memorized data and escape this page, move the joystick right or press the
pan right key when the cursor is at SAVE AND EXIT.
E-8. AUTO SCAN – EXIT
To escape this page, move the joystick right or press the pan right key.
30
Page 31
OSD MENU SETTING
F. TOUR SET
8 Programmable tours can be set and each tour can have up to 64 preset steps. After setting up the
tours the 71~78 + preset buttons launch group tours # 1~8
TOUR SET
TOUR NO : 01 TOUR TITLE : TOUR01 TOUR STEP : 01 PRESET NO. : 01 DWELL TIME : 03 SPEED : 200°/S SAVE EXIT
DEFAULT SETTING
F-1. TOUR SET – TOUR NO.
Up to 8 group tours can be programmed.
F-2. TOUR SET – TOUR TITLE
To set a tour title, use the joystick left/right or pan left/right keys. Each title can have up to 16
characters.
Press ZOOM TELE button to move the next character from left to the right and ZOOM WIDE
button to move the next character from right to left (Space displays when appears) The tour title
is not displayed on the monitor and is only for the reference of user.
F-3. TOUR SET – TOUR STEP
Each tour group consists of up to 60 preset steps with different dwell time and speed. It is possible
to match any preset # for any tour step.
F-4. TOUR SET – PRESET NO.
For each tour step it is possible to select any preset number up to 64. The default setting is BLK
F-5. TOUR SET – DWELL TIME
Dwell time can be programmed from 1-99 seconds. The default setting is 03 seconds.
F-6. TOUR SET – SPEED
Each tour step can be set with a different speed up to 200°/S and it is selectable from 10°/S. The
default setting is 200°/S.
F-7. TOUR SET – SAVE
To save the memorized data and escape this page, move the joystick right or press the pan
right key when cursor is at SAVE
F-8. TOUR SET – EXIT
To escape this page, move the joystick right or press the pan right key.
31
Page 32
OSD MENU SETTING
G. PRIVACY SET
4 Privacy masking zones can be set.
PRIVACY SET
PRIVACY NO : 01 DISPLAY : OFF ACTION : MOVE SAVE EXIT
DEFAULT SETTING
G-1. PRIVACY SET – PRIVACY NO.
Up to 4 privacy masking zones can be set.
G-2. PRIVACY SET – DISPLAY.
Move the joystick right or left or press pan right/left to set ON in order to show the selectable block
in the center of the monitor. This block appears as a translucent square with blue color when set
ON. The default setting is OFF.
G-3. PRIVACY SET – ACTION (MOVE / ADJUST)
To set the blocking area, press FOCUS FAR button when MOVE MODE is displayed. Then use
the joystick or pan keys to the user defined area in order to set the blocking area. Then press
FOCUS FAR button again to escape from MOVE MODE.
To adjust the size of the blocking area, move the joystick or use the pan keys when the cursor is on
ACTION. After it has changed to ADJUST MODE, press FOCUS FAR button in order to adjust the
size of the blocking area. The size of the blocking area can be adjusted by using joystick up/down
or left right – or the pan and tilt keys. After adjusting the size of the blocking area, press FOCUS
FAR button to escape the ADJUST mode.
z ADJUST: You can change the masking size by using the joystick or pan keys
z MOVE: You can move the masking area by using the joystick or pan keys (Default)
G-4. PRIVACY SET – SAVE
After setting the privacy masking zone, to save the data, move the joystick right or pan right key
when the cursor is on SAVE. After saving the data, the cursor moves to PRIVACY NO.2
automatically to prepare for the next privacy masking zone.
G-5. PRIVACY SET –EXIT
To escape this page, move the joystick right.
32
Page 33
H. PATTERN SET
8 programmable patterns are available, each with a programmable title.
After setting up each pattern # 1~8, 81~88+ preset buttons will recall Patterns # 1~8.
OSD MENU SETTING
PATTERN SET
PATT NO : 01 PATT TITLE: PATTERN01□□□□□□□ DATA FILL : 0% SAVE EXIT
DEFAULT SETTING
H-1. PATTERN SET –PATT NO.
Up to 8 programmable user-defined patterns are available.
H-2. PATTERN SET –PATT TITLE
To set PATTERN TITLE move Joystick left/right or use the pan keys.
Press ZOOM TELE button moves to the next character from the left / right and ZOOM WIDE button
moves to the next character from the right / left (Space displays when appears) The pattern title
is not displayed on the monitor, but only for the reference of the user.
H-3. PATTERN SET –DATA FILL
To memorize a pattern, press FOCUS FAR button in order to start the process. The progress is
shown as % filled. Press FOCUS FAR button again in order to escape.
H-4. PATTERN SET –SAVE
To save the memorized pattern data, move the joystick right or press the pan right key when the
cursor is on SAVE. Then the cursor moves to the PATT NO.02 in order to prepare for the next
pattern.
H-5. PATTERN SET –EXIT
To escape this page, move the joystick right or press the pan right key.
33
Page 34
I. ALARM SET
4 Alarm inputs are available and each input can activate presets, group tours or patterns.
OSD MENU SETTING
ALARM SET
ALARM NO : 01 ALARM INPUT: OFF ALARM ACT : 001 SAVE EXIT
DEFAULT SETTING
I-1. ALARM SET – ALARM NO.
Up to 4 alarms are selectable by using joystick right or pressing the pan right key when the cursor
is on ALARM NO.
I-2. ALARM SET – ALARM INPUT
Alarm inputs can be programmed as NC (Normally Close) or NO (Normally Open)
The default setting is OFF
I-3. ALARM SET – ALARM ACT
Active alarms can trigger modes such as presets, Group tours 1-8, and Patterns 1-8.
Use the joystick or pan keys to select any preset number, group tour no. or pattern no.
I-4. ALARM SET – SAVE
After setting up the alarm features, to save the data move the joystick right or press the pan right
key when the cursor is on SAVE. After saving the data, the cursor moves to Alarm NO.2
automatically to prepare for the next alarm.
I-5.
ALARM SET –EXIT
To escape this page, move the joystick right or press the pan right key.
* Before activating Alarms, you must set ALARM ENABLE at DOME SET – ALARM – ENABLE
(Refer to page 15)
34
Page 35
J. SECTOR SET
Up to 8 programmable sectors are available, each with a 16 character title.
This feature allows the various areas of the domes 360° rotation to be given logical titles.
When the dome is moved the relevant title for each area is displayed as the dome passes
through the area.
OSD MENU SETTING
SECTOR SET
SECTOR NO : 01 SECTOR ID: SECTOR01□□□□□□□□ SECTOR START: XXX.X.XX.X SECTOR END : XXX.X.XX.X SAVE EXIT
DEFAULT SETTING
Start Position
End Position
J-1. SECTOR SET – SECTOR NO.
Up to 8 programmable sectors are available.
J-2. SECTOR SET – SECTOR ID
To set a SECTOR ID, use the joystick or pan left/right keys.
Press ZOOM TELE button to move to the next character from left to right and ZOOM WIDE button
to move to the next character from right to left (Space displays when appears)
J-3. SECTOR SET – SECTOR START
To set a SECTOR START position, press FOCUS FAR button then move the joystick or pan keys to
set the position. Press FOCUS FAR button again to escape.
J-4. SECTOR SET – SECTOR END
To set a SECTOR END position, press FOCUS FAR button then move the joystick or pan keys to
set the position. To press FOCUS FAR button again to escape.
J-5. SECTOR SET – SAVE
After setting the SECTOR positions, to save the data move the joystick right or press the pan right
key when the cursor is on SAVE. After saving the data, the cursor moves to SECTOR NO.2
automatically to prepare for the next SECTOR.
J-6. SECTOR SET –EXIT
To escape this page, move the joystick right or press the pan right key.
K. EXIT
To escape OSD Main Menu, move joystick to the right re
35
Page 36
DIP SWITCH SETTING
A. FACTORY DEFAULT SETTING
The dome cameras RS 485 address is set using switches 1-6 of DIP SW1, refer to the table below...
Open the camera case to set ID using DIP SW1.
* Factory default: Camera ID = 1, PELCO-D Baud Rate: 2400bps
Termination
Protocol
ID Set
Baud rate
B. ID SETTING (1-ON, 0-OFF) (1Î10)
DIP SW ID VALUE DIP SW ID VALUE DIP SW ID VALUE
100000XXXX 1 111010XXXX 23 101101XXXX 45 010000XXXX 2 000110XXXX 24 011101XXXX 46
110000XXXX 3 100110XXXX 25 111101XXXX 47 001000XXXX 4 010110XXXX 26 100011XXXX 48 101000XXXX 5 110110XXXX 27 100011XXXX 49
011000XXXX 6 001110XXXX 28 010011XXXX 50
111000XXXX 7 101110XXXX 29 110011XXXX 51 000100XXXX 8 011110XXXX 30 001011XXXX 52 100100XXXX 9 111110XXXX 31 101011XXXX 53 010100XXXX 10 000001XXXX 32 011011XXXX 54
110100XXXX 11 100001XXXX 33 111011XXXX 55
001100XXXX 12 010001XXXX 34 000111XXXX 56
101100XXXX 13 110001XXXX 35 100111XXXX 57
011100XXXX 14 001001XXXX 36 010111XXXX 58
111100XXXX 15 101001XXXX 37 110111XXXX 59 000010XXXX 16 011001XXXX 38 001111XXXX 60 100010XXXX 17 111001XXXX 39 101111XXXX 61 010010XXXX 18 000101XXXX 40 011111XXXX 62
110010XXXX 19 100101XXXX 41 111111XXXX 63 001010XXXX
20
010101XXXX
42
101010XXXX 21 110101XXXX 43
011010XXXX
22
001101XXXX
44
36
Page 37
DIP SWITCH SETTING
C. PROTOCOL SETTING
7th~8th dip switches are used for Protocol Setting.
Factory Default: Pelco-D or Pelco-P (Auto detection)
DIP SW1- 7 DIP SW1- 8
OFF OFF Pelco-D or Pelco-P
ON OFF VICON
OFF ON SAMSUNG
ON ON
D. BAUD RATE SETTING
The 9th Dip Switch is used for BAUD RATE setting.
DIP SW can be changeable to 2400bps, 9600bps.
Factory Default: 2400bps. (If user selects Vicon protocol, then Baud rate is automatically set as
4800bps.
DIP SW1 9
th
BAUD RATE
OFF
2400bps(Default) 4800bps(VICON)
ON 9600bps
.
E. 485 TERMINATIONS
10th Dip Switch is used for 100 termination.
Set on 10
th
Dip Switch only for the last looped camera from the controller.
Even in case of only one camera, set on 10
th
Dip Switch of the camera.
37
Page 38
If you have trouble setting up or operating the camera, refer to the following.
PROBLEM
SOLUTION
No operation
Check if the power supply is DC12V. Check if RS-485 communication cable is connected correctly. Check camera ID setting. Check the RS 485 termination.
No picture
Check if all the cables are connected correctly. Check if the monitor is adjusted correctly. Check for video locally at the dome.
Dark screen Check video termination and monitor settings
Abnormal camera Check if PSU voltage level at the dome
operation Check the RS 485 termination.
TROUBLE SHOTING
38
Page 39
SPECIFICATIONS
MODEL 10X A/F CAMERA MODULE
Pan Rotation Angle 360˚ Endless
Manual 100˚ ~ 150˚/sec
Pan Speed
Preset Max 200˚ /sec
Tilt Rotation Angle 0˚ ~ 90˚
Manual 100˚ ~ 150˚/sec
Tilt Speed
Preset Max 200˚ /sec
PAN /TILT
System Accuracy 0.2˚
165 positions with a 16-character label available for each
position with different speed steps
Presets
Max. 8 Programmable group tours (each one consisting of up
to 60 preset steps with different steps)
Group Tour
Auto scan Programmable Auto scan Pattern 8 Programmable Patterns (total 480 seconds) Privacy Zone 4 privacy zones ­Sector 8 selectable Sectors with 16 characters Password Protection Yes Alarm Input 4 alarms OFF/NC/NO (with various programmable states) Alarm Actions Activate preset, Group scanning or Patterns Auto Flip ON / OFF OSD Menu Multiple Languages on screen Communication RS-485
FUNCTIONS
Protocol Pelco D/P, Vicon, Samsung Consumption (12V DC) 9W Max (Heater Type 15W) Consumption (24V AC) 18W Max (Heater Type 30W) Power Supply(12V DC) DC12V 750mA (Heater Type DC12V 1.2W)
POWER
Power Supply(24V AC) AC 24V 650mA (Heater Type AC24V 1.3W) Construction die-casting , Anti-vandal dome cover Dimensions 158.8φ (D) * 163.0mm(H) Weight 1.5 kg Motor Type Stepper Motor Micro Steps 1/4 Step Storage Temperature -10 ~ 60 Operating Temperature 0 ~ 50
OTHERS
Certifications CE, FCC, IP66 Image Sensor 1/4" Sony Super HAD CCD
NTSC 811(H) * 508(V) 410K
Total Image Pixels
PAL 795(H) * 596(V) 470K NTSC 768(H) * 494(V) 380K Number Of Effective
Pixels
PAL 752(H) * 582(V) 440K
Horizontal resolution More Than 500TV Lines
Optical 10x Optical Zoom (F=3.8 to 38mm)
Lens
Digital 10x (100x with optical) Day & Night (ICR) Auto/ Day/ Night Min. Shooting Distance 0.35m(Wide)/0.8m(Tele) Digital Slow Shutter 2/4/8/16/24/32/64/128/ OFF
Normal mode 0.7Lux (50IRE)
Min. illumination
Night mode 0.02Lux (ICR On) Luminance S/N Ratio More than 50dB Video Output VBS:1.0Vp-p/75 Ohm BLC ON / OFF
NTSC ON / OFF (1/100) Flicker less
PAL ON / OFF (1/120)
CAMERA MODULE
WHITE BALANCE AWB/ATW/INDOOR/ OUTDOOR
39
Page 40
DIMENSIONS
40
Loading...