SPECIFICATION
MODEL
DC VOLTAGE
CONSTANT CURRENT REGION
RATED CURRENT
RATED POWER
RIPPLE & NOISE (max.)
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
NOTE
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
TOTAL HARMONIC DISTORTION
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
LEAKAGE CURRENT
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSIONOTHERS
PACKING
80W Single Output Switching Power Supply
■
IP65 IP67
HLG-80H-12 HLG-80H-15 HLG-80H-20 HLG-80H-24 HLG-80H-30 HLG-80H-36 HLG-80H-42 HLG-80H-48 HLG-80H-54
12V
7.2 ~12V
Note.4
5A 5A 4A 3.4A
60W 75W 80W 81.6W 81W
Note.2
150mVp-p 150mVp-p
Note.6
Can be adjusted by internal potentiometer A type only
3 ~ 5A
±2.5%
Note.3
±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±2.0%
Note.8
1200ms,80ms/115VAC 500ms,80ms/230VAC at full load ; B type 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load
16ms at full load 230VAC /115VAC
Note.5
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
THD< 20% when output loading 60% at 115VAC/230VAC input and output loading 75% at 277VA C input≧ ≧
88%
0.85A / 115VAC 0.425A / 230VAC 0.4A / 277VAC
COLD START 70A(t =485 s measured at 50% I ) at 230VAC
3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
<0.75mA / 277VAC
95 ~ 108%
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
14 ~ 17V
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
-40 ~ +70 (Refer to "Derating Curve")℃
20 ~
-40 ~ +80 , 10 ~ 95% RH℃
± ℃ ℃0.03%/ (0 ~ 60 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, CSA C22.2 No. 250.0-08(except for HLG-80H-48/54V & HLG-80H-48/54BL), UL8750 listed for HLG-80H- BL, EN61347-1,□
Note.7
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3≧
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light
357.8K hrs min. MIL-HDBK-217F (25 )℃
195.6*61.5*38.8mm (L*W*H)
0.84Kg; 16pcs/14.4Kg/0.54CUFT
15V
9 ~ 15V
13.5 ~ 17V
3 ~ 5A
±2.0%
20V
12 ~ 20V
150mVp-p
17 ~ 22V
2.4 ~ 4A
±1.0%
24V
14.4 ~ 24V
150mVp-p
22 ~ 27V
2.04 ~ 3.4A
±1.0%
±1.5% ±1.0% ±0.5% ±0.5%
89%
90%
μ
18 ~ 24V
23 ~ 30V
95% RH non-condensing
90.5%
28 ~ 35V
kaephtdiw
HLG-80H series
30V
18 ~ 30V
2.7A
200mVp-p
27 ~ 33V
1.62 ~ 2.7A
±1.0%
91%
35 ~ 43V
36V
21.6 ~ 36V
2.3A
82.8W
200mVp-p
33 ~ 40V
1.38 ~ 2.3A
±1.0%
±0.5%
±0.5%
91%
41 ~ 49V 54 ~ 63V
76PI ro 56PI, optional models for J61347-1, J61347-2-13,
industry level (surge 4KV), criteria A
℃
Bauar
tgepruft
Sicherheit
egel gema
od
o s
be
wac g
www.
tuv.com
ID 2000000000
42V
25.2 ~ 42V
1.95A
81.9W
200mVp-p
38 ~ 46V
1.17 ~ 1.95A
±1.0%
±0.5%
±0.5%
48 ~ 58V
48V
28.8 ~ 48V
1.7A
81.6W
200mVp-p
43 ~ 53V10.8 ~ 13.5V
1.02 ~ 1.7A
±1.0%
±0.5%
±0.5%
54V
32.4 ~ 54V
1.5A
81W
200mVp-p
49 ~ 58V
0.9 ~ 1.5A
±1.0%
±0.5%
±0.5%
91%91% 91%
59 ~ 68V
1-05906NE VUT,1-05906LU ot refer ngiseD ; devorppatnednepedni 31-2-74316NE
File Name:HLG-80H-SPEC 2015-05-11
80W Single Output Switching Power Supply
HLG-80H s eries
Mechanical Specification
Blank:(HLG-80H)
AC/L(Brown)
AC/N(Blue)
FG (Green/Yellow)
A Type:(HLG-80H-_A)
SJTW 18AWG 3C×
※ IP67 rated. Cable for I/O connection.
300 20±
12
9.6
5.165.16
5.645.64
2323
※ T case: Max. Case Temperature.
12
9.6
195.6
171.8
T case
195.6
171.8
Case No.997A Unit:mm
300 20±
57.03
85.9
SVT 18AWG 2C×
ψ ×4.2 4PL
+V(Red)
-V(Black)
8.83
AC/L(Brown)
AC/N(Blue)
FG (Green/Yellow)
B Type:(HLG-80H-_B)
AC/L(Brown)
AC/N(Blue)
FG (Green/Yellow)
300 20±
SJTW 18AWG 3C×
T case
57.03
85.9
ADJ.
Io
Vo
ADJ.
SVT 18AWG 2C×
ψ ×4.2 4PL
※ T case: Max. Case Temperature.
※ IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
(Can access by removing the rubber stopper on the case.)
195.6
171.8
T case
57.03
85.9
SVT 18AWG 2C×
UL2517 18AWG 2C×
ψ ×4.2 4PL
300 20±
SJTW 18AWG 3C×
12
9.6
5.64
5.16
23
※ T case: Max. Case Temperature.
300 20±
300 20±
+V(Red)
-V(Black)
8.83
+V(Red)
-V(Black)
DIM+(Blue)
DIM-(White)
8.83
File Name:HLG-80H-SPEC 2015-05-11