THAT HAS THE CONSTRUCTION FEATURES AND DIMENSIONS SHOWN IN THE PHOTOGRAPHS AND/OR DRAWINGS AND WHERE THE INPUT RATING OF THE RETROFIT KIT DOES NOT EXCEED THE INPUT RATING OF THE LUMINAIRE.
AVERTISSEMENT – RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE. N’INSTALLER CE NÉCESSAIRE QUE DANS LES LUMINAIRES DONT LES CARACTÉRISTIQUES DE CONSTRUCTION ET LES DIMENSIONS SONT CONFORME À CELLES ILLUSTRÉES DANS LES PHOTOS ET/OU LES DESSINS ET DONT LA PUISSANCE D’ENTRÉE NOMINALE DU NÉCESSAIRE DE MODERNISATION NE DÉPASSE PAS CELLE DU LUMINAIRE. ___________________________________________________________________________________________
THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION. (S24-L5)
LE NÉCESSAIRE DE MODERNISATION EST ACCEPTÉ À TITRE DE COMPOSANT D’UN LUMINAIRE LORSQUE LA PERTINENCE DE LA COMBINAISON DOIT ËTRE DÉTERMINÉE PAR PAR LES AUTORITÉS COMPÉTENTES ___________________________________________________________________________________________
RK94
DO NOT MAKE OR ALTER ANY OPEN HOLES IN AN ENCLOSURE OF WIRING OR ELECTRICAL COMPONENTS DURING KIT INSTALLATION.
IL EST INTERDIT DE FAIRE OU DE MODIFIER UNE OUVERTURE DANS UN BOÎTIER DE CÂBLAGE OU DE COMPOSANTS ÉLECTRIQUES AU COURS DE L’INSTALLATION DU NÉCESSAIRE. (S24-L5) ___________________________________________________________________________________________
WARNING – RISK OF FIRE OR ELECTRIC SHOCK. INSTALLATION OF THIS RETROFIT ASSEMBLY REQUIRES A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE LUMINAIRE’S ELECTRICAL SYSTEM AND THE HAZARD INVOLVED. IF NOT QUALIFIED, DO NOT ATTEMPT INSTALLATION. CONTACT A QUALIFIED PERSON.
AVERTISSEMENT – RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE. L’INSTALLATION DE CE NÉCESSAIRE DE MODERNISATION EXIGE UNE PERSONNE FAMILIÈRE AVEC LA CONSTRUCTION ET LE FONCTIONNEMENT DU SYSTÈME ÉLECTRIQUE DU LUMINAIRE ET DES RISQUES ASSOCIÉS. TOUTE PERSONNE QUI N’EST PAS QUALIFIÉE NE DOIT FAIRE AUCUNE TENTATIVE D’INSTALLATION ET DOIT CONTACTER UNE PERSONNE QUALIFIÉE.
Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the fixture shown without further notification.
1625 Surveyor Avenue • Simi Valley, CA 93063 • (805) 527-0987 • (800) 766-VISTA (8478)
FAX: (888) 670-VISTA (8478) • email@vistapro.com • www.vistapro.com
1/6
RK94
r
Architectural Series
LED Retrofit Kit
INSTALLATION INSTRUCTIONS
IMPORTANT NOTE:
• Retrofit Kit must be installed and grounded in accordance with the National Electrical Code (NEC) and local codes.
• All conduit entries must be sealed from moisture. Use appropriate sealing material on conduit fittings and conduit closure plugs.
• Retrofit Kit is wet location listed and suitable for mounting in Hydrel® Model M9400 Series in-grade rough-in sections.
• Suitable for all types of construction including poured concrete construction and in soil applications.
• Suitable for through wiring: Max. of (4) No. 12 AWG conductors (plus ground) rated for 90°C.
MAINTENANCE: To assure proper operation and efficiency and to prevent luminaire overheating, lens must be kept clean and free of dirt, dust, leaves, trash and mineral deposits from water. A regular schedule maintenance program is recommended.
NOTE: Save these instructions for future reference.
NOTICE: To prevent electric shock, turn main power off at circuit breaker. DO NOT INSTALL RETROFIT WHILE SYSTEM IS ENERGIZED.
Disassembly of Existing Fixture-HID/Fluorescent Version:
1. Remove and discard existing door assembly.
2. Remove and discard existing Lamp Module and any associated bracketry and hardware by lifting the Lamp Module out of the Housing and unplugging it from the Power Module.
3. Loosen Support Ring screws and remove Support Ring from the Housing. Retain Support Ring and screws as these will be reused later. Inspect
components for damage and replace any damaged parts prior to installation of the Reftrofit Kit.
4. Remove Power Module from Housing and set on grade outside of fixture.
5. Remove J-Box Cover and disconnect the wiring splices within the J-Box. Discard the old Wire-Nuts.
6. Pull J-Box Cover from within the Housing and remove the Cord Seal from the J-Box Cover. Discard the Power Module along with the old Cord Seal.
Retain J-Box Cover with gasket and screws as these will be reused later. Inspect components for damage and replace any damaged parts prior to installation of the Reftrofit Kit.
Disassembly of Existing Fixture HID/Fluorescent Version
DOOR ASSEMBLY
(may include glass)
emove and discard
LAMP MODULE
(and associated bracketry)
remove and discard
POWER MODULE
remove and discard
J-BOX COVER
remove and retain
SUPPORT RING
remove and retain
HID/FLUORESCENT HOUSING
fixed and buried
OLD CORD SEAL
& OLD WIRE-NUTS
remove and discard