Visonic Quatro+ Installation Instructions Manual

Page 1
48$752
QUAD Passive Infra Red Detector
,1752'8&7,21
The QUATRO+ is a QUAD passive infrared detector which employs a quad element pyroelectric sensor, providing two completely separate dual element PIR detectors for increased reliability (Fig. 1).
A choice of four interchangeable lenses is provided: wide angle, long-range, ultra-wide angle and pet alley.
The two separate dual passive infrared detectors use the same optical system to cover t he same area. The zones monitored by detector 1 are positioned slightly above the zones monitored by detector 2. Both detectors must be tripped simultaneously to activate an alarm. This provides a hi gh immuni ty agai nst fal s e alar ms c aus ed by various heat sources or rodent s, which ar e located in t he field of view of only one detector and not in the other. The QUATRO+
Figure 1- QUATRO+ Quad
Elements
63(&,),&$7,216
Installation Instructions
principle of operation and its unique special processing method increase the immunity to internal circuit noise and random environmental distur­bances, without compromising detector sens itivity.
Both dual PIR detectors (1 and 2) have independent, alternate polarity pulse count signal process ing circ uits – one for each detector.
When alternate polarity pulse count signal processing is selected, each PIR (1 and 2) must detect motion in both of their fi elds (+) and (–).
This means that motion must be detected in all four fields (beams) of a zone to report an al arm - see Figure 1. This signal processing provides QUATRO+ with unprecedented protection against false alarms.
A special QUATRO+/S model, wit h for m C c ontac ts ( N.O. + N.C. ) is also availabl e.
Lens A. Wide Angle (standard) Maximum Coverage 12 X 12 m (40 X 40 ft)
OPTICAL Detection Patterns:
LENS-A: 90° Wide Angle. Provides 34 beams in 3 detection
layers with maximum coverage area of 12 x 12 m (40 x 40 ft). LENS-B: Long Range. Provides narrow angle corridor pattern with maximum coverage area of 3 x 27 m (10 x 90 ft). LENS-C: 145° Ultra-W ide Angle. Provides 34 beams in 3 det­ection layers with max. coverage area of 12 x 18 m (40 x 60 ft). LENS-D: 90° Pet Alley. Provides 14 beams in a s ingle layer with maximum coverage area of 13.5 x 13.5 m (45 x 45 ft).
Optical Adjustment: Vert ical 0° to -12° cali brated scale. COVERAGE PATTERNS
The QUATRO+ has a selection of four interchangeable lenses:
Lens B. Long Angle Maximum Coverage 3 X 27 m (10 X 90 ft)
Figure 2- QUATRO+ Coverage Patterns
Lens C. Ultra Wide Angle
Maximum Coverage 12 X 18 m (40 X 60 ft)
wide angle, long range, ultra-wide angle and pet alley. The appropriate lens can be selected for each particular
application according to the area to be c overed (Fig. 2).
ELECTRICAL Voltage: 9 to 16 VDC. Current: 17 mA at 12 VDC. Alarm Output: Normally closed (fail-safe) contacts. 18 ohm
resistor in series with contacts. Rating - 0.1A resistive / 24 VDC. Tamper Output: Normally closed. Rating - 0.5A resistive / 24 VDC.
Alarm Period: 2-7 seconds. Pulse Counter: Alternate polarity pulse count operation. LED: Walk Test enabled or disabl ed with internal link. Detector: Quad-element low noise pyroelectric detector.
Lens D. Pet Alley
Maximum Coverage 13.5 X 13.5 m (45 X 45 ft)
Note: To allow extra free height for pets, set the vertical adjustment scale to +2°. Install the detector at a height that places the detection pattern at least 30 cm (1 ft) above the pet ’s activity
.
DE1606 1
Page 2
MOUNTING
Flat or corner mounting (no additional brackets required).
Mounting Height: Optional Mounting Accessories:
BR-1 - Swivel bracket (optional), adjustable 30° downward and 45° left, 45° right. BR-2 - Same as BR-1, with corner adapter. BR-3 - Same as BR-1, with ceiling adapter.
ENVIRONMENTAL
Up to 3.6 m (12 ft).
Note: The unit shall be mounted indoors
Operating Temperatur e:
-10°C to 50°C (14°F to 122°F).
,167$//$7,21
&KDQJLQJ/HQVHV
To change a lens: inser t a small sc rewdriver i nto the lens holder side locking tab and rotate the screwdriver handle downward. The lens holder will release (Fig. 3).
Insert the new lens with the smoot h surfac e outside and the lens designation letter in the upper right corner (Fig. 4). Carefully center the lens s o that the di stanc e from its edges t o the edge of the cover is the s ame on each s ide of t he cover . Hol ding t he lens firmly in plac e install the l ens holder, pushi ng it toward the c over until a clic k is heard.
Storage Temperature: RFI Protection:
PHYSICAL Dimensions: Weight: Color:
MODELS AVAILABLE QUATRO+ ­QUATRO+/S -
contacts.
The BR-3 is a swivel br acket kit t hat consists of the BR-1 and a ceiling mounting adapt er.
60 x 104 x 32 mm (2-3/8 x 4-1/8 x 1-5/16 in).
95 g (3.3 oz).
White.
Standard version
Same as standard versi on, but with form C r elay
-20°C to 60°C (-4°F to 140°F).
Greater than 20V/m to 1000 MHz.
ATTENTION: with swivel brackets in use, the effective detection range may differ from that indi cated in Table 1 – the vertical adjusting scale.
Figure 3. Removing the
Lens Holder
Figure 4. Construction and
Assembly
0RXQWLQJ
Attention! This unit is designed for indoor use only.
The QUATRO+ PIR can be installed directly on a wall (surface mounted) or in a corner. An optional PIR mounting bracket (BR-1) is also availabl e,( par a. 3.3 and Fi g. 5. ) Always mount the uni t on a firm and stable surface.
A. Select the mounting l ocation so that the expected motion of an
intruder will cross the beams of the coverage patter n.
B. Select the most convenient mounting height. Built-in
installati on aids enable you to mount the unit anywhere up to 3 m (10 ft) height. An accurate adjustment table determines the recommended angles for various combinations of range and mounting height (Table 1)
C. QUATRO+ is extremely immune to air turbulence and RFI
interference. However , to minimize pos sible fals e alarms, it is highly recommended to avoid ai ming the detector at heater s, sources of li ght, or windows s ubjected to direc t sunlight. Also avoid running wiring c lose to high power electrical cables .
D. Remove the front cover (Fig. 3). Mount the base (equipped
with the printed circuit board) in the location and height selected for opt imum cover age. For sur face mounti ng use the two knockouts at the back of the base; for c orner mounting use the knockouts on the angled sides. The unit must be fastened firmly to the mounting surface to avoid possible vibrations.
E. Seal all openings in the base wit h RTV to prevent i nsects and
air drafts from entering the unit.
2SWLRQDO6ZL YHO %UDFNHWV
The BR-1 is a swivel, surface-mounted bracket for greater flexibility when setting the desired detect ion r ange. I t is adjust able as shown in Figure 5. The BR-2 is a swivel bracket that consists of the BR-1 and a corner mounting adapter.
Figure 5 - Optional Swivel Brackets
:LULQJ
To route wires into the detector, use either the wiring knockout s loc at ed at the bottom of the unit base, or the channel on the backside of the base and its knockout. The channel allows wire r outing under the detector from the ceiling side (Fig. 6). Refer to Figure 7 and connect wires to the termi nal block in the following order.
A. Connect TAMP N.C.
terminals to a normally closed 24-hour protec-
tion zone of the c ontrol
panel. Tamper contact will open when cover is removed.
B. Connect RELAY N.C.
terminals to a normally closed burglar zone of the control panel. Relay contacts will open when motion is detected or during power loss.
C. Connect the 12VDC (+)
and (–) terminals to a 9
Figure 6 - Printed Circuit Board
Layout
Figure 7 - Terminal Block W iring
2 DE1606
Page 3
to 16 Volt DC power sourc e and check f or correc t polari ty. It is advisable that the power supply be battery backed-up. Current drain of each sensor is approximately 15 mA.
9HUWLFDO $GMXVWPHQW
The vertical adjust ment s cal e ( pri nted on t he upper ri ght c or ner of the p.c. board) and the plastic pointer on the base indicate in degrees the approximate vertical angle between the horizontal line of the unit and the upper detection layer.
Table 1 gives the recommended scale adjustment for various combinations of mounting height and coverage distance. The scale enables fast, easy pattern adjustment from 0° to -12° downward according to the installation height and the required coverage range.
Table 1. Vertical Adjusting Scale
All QUATRO+ sensors ar e factory preset to -4°. To change the vertical pattern adjustment, loosen the screw whic h fastens the printed circui t board to the rear cover . Slide the p.c. board up or down to the desired angle and t ighten the screw firmly.
In operation, a pers on must cr oss bot h the upper and lower PIRs together to initi ate an alarm (Fig. 1).
It is of utmost importanc e that a walk t es t be made over t he enti re coverage area to assure that both upper and lower beams will be crossed. This is of particular importance when using the long range lens (Lens B).
48$7523XOVH&RXQWHU
The QUATRO+ QUAD PIR is equipped with two independent alternate polari ty pulse count circuits and controls (Fig. 6). The Upper Detector (1) is controll ed with pulse count sw itch 1. The Lower Detector (2) is controll ed with pulse count sw itch 2. Placing both swit ches to ON selects the al ternate polarity pulse count operation for both detec tors. A person i s required to cr oss
both the (+) and (–) beams of both dual element detec tors (1 and
2) before activation of the alarm relay. This means that motion must be detected by all 4 beams (Fig. 1) . Use of the pul se count is recommended only in a temperature controlled environment where the temperature does not exceed 28°C (82°F).
Placing both switches at OFF actually disables the puls e counters of both detectors. This should be done if it is necessary to activate an alarm in the firs t crossi ng of a vertical pai r of beams, such as with a long range lens or in high security installations when high 'catch' performance is required. Still, both detectors (one beam each) must be triggered.
To ensure proper detection when using the long range lens, pulse count one must be selected for both the upper and lower detectors. Set both switches to OFF.
With two pulse count switches you can select pulse count operation on only one detector (1 or 2) . This f lexibility may prove useful in certain applications which require different catch performance levels in the same area.
:DON7HVWLQJ
A. Apply 12 VDC power and allow five minutes for the unit to
warm up and stabilize before testing.
B. Adjust the vertical patter n angle according to Table 1.
Note: be careful to position the printed circuit board so that
the upper and lower beams reach the maximum required distance. This can be achieved by careful vertic al adjustment and walk testing.
C. Place the LED jumper at ON (across the mi ddle and top pi ns)
to activate the LED.
D. Set the pulse counter per para 3.6 above. E. Walk-test the range and coverage area by walking slowly
across the field of view (in opposite directions) and observe the LED. The LED lights up whenever you cross a pair of vertical sens iti ve beams. Allow 10 s econds bet ween each test for the unit to stabilize.
F. Aft er tes t ing, the LED can be disabl ed to pr event unauthor ized
persons from tracing the coverage pattern. To disable the LED, remove the LED jumper from the ON position (across the middle and upper pins) and place it in the OFF position (across the mi ddle and lower pins).
NOTE: The range and coverage area should be chec ked at least once a year . To assure proper conti nuous functioning, the user should be ins t ruc t ed to per f orm a walk tes t at t he far end of the coverage pattern to assure an alarm signal.
:$55$17<
:$55$17<
Visonic Ltd. and/or its subsidiaries and its affiliates ("the Manufacturer") warrants its products hereinafter referred to as "the Product" or "Products" to be in conformance with its own plans and specifications and to be free of defects in materials and workmanship under normal use and service for a period of twelve months from the date of shipment by the Manufacturer. The Manufacturer's obligations shall be limited within the warranty period, at its option, to repair or replace the product or any part thereof. The Manufacturer shall not be responsible for dismantling and/or reinstallation charges. To exercise the warranty the product must be returned to the Manufacturer freight prepaid and insured. This warranty does not apply in the following cases: improper installation, misuse, failure to follow installation and operating instructions, alteration, abuse, accident or tampering, and repair by anyone other than the Manufacturer. This warranty is exclusive and expressly in lieu of all other warranties, obligations or liabilities, whether written, oral, express or implied, including any warranty of merchantability or fitness for a particular purpose, or otherwise. In no case shall the Manufacturer be liable to anyone for any consequential or incidental damages for breach of this warranty or any other warranties whatsoever, as aforesaid.
This warranty shall not be modified, varied or extended, and the Manufacturer does not authorize any person to act on its behalf in the modification, variation or extension of this warranty. This warranty shall apply to the Product only. All products, accessories or attachments of others used in conjunction with the Product, including batteries, shall be covered solely by their own warranty, if any. The Manufacturer shall not be liable for any damage or loss whatsoever, whether directly, indirectly, incidentally, consequentially or otherwise, caused by the malfunction of the Product due to products, accessories, or attachments of others, including batteries, used in conjunction with the Products.
VISONIC LTD. (ISRAEL): P.O.B 22020 TEL-AVIV 61220 ISRAEL. PHONE: (972-3) 645-6789, FAX: (972-3) 645-6788 VISONIC INC. (U.S.A.): 10 NORTHWOOD DRIVE, BLOOMFIELD CT. 06002-1911. PHONE: (860) 243-0833, (800) 223-0020 FAX: (860) 242-8094 VISONIC LTD. (UK): UNIT 1, STRATTON PARK, DUNTON LANE, BIGGLESWADE, BEDS. SG18 8QS. PHONE: (01767) 600857 FAX: (01767) 601098
VISONIC LTD. 1998 QUATRO+ D-1606-0 NEW: DE1606- (REV. 1, 4/98)
The Manufacturer does not represent that its Product may not be compromised and/or circumvented, or that the Product will prevent any death, personal and/or bodily injury and/or damage to property resulting from burglary, robbery, fire or otherwise, or that the Product will in all cases provide adequate warning or protection. User understands that a properly installed and maintained alarm may only reduce the risk of events such as burglary, robbery, and fire without warning, but it is not insurance or a guarantee that such will not occur or that there will be no death, personal damage and/or damage to property as a result.
The Manufacturer shall have no liability for any death, personal and/or bodily injury and/or damage to property or other loss whether direct, indirect, incidental, consequential or otherwise, based on a claim that the Product failed to function.
However, if the Manufacturer is held liable, whether directly or indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless of cause or origin, the Manufacturer's maximum liability shall not in any case exceed the purchase price of the Product, which shall be fixed as liquidated damages and not as a penalty, and shall be the complete and exclusive remedy against the Manufacturer. Warning: The user should follow the installation and operation instructions and among other things test the Product and the whole system at least once a week. For various reasons, including, but not limited to, changes in environmental conditions, electric or electronic disruptions and tampering, the Product may not perform as expected. The user is advised to take all necessary precautions for his /her safety and the protection of his/her property.
6/91
DE1606 3
Loading...