NEXT PLUS
PIR, K9-85, DUO, DUO K9-85, DUO AM, DUO AM K9-85
English
Español
Portuguese
ENGLISH
1. FEATURES
• Combined Fresnel and cylindrical optics improves detection range and false
alarm immunity.
• Advanced True Motion Recognition algorithm (patented) reduces false alarms.
• Easy installation, free of vertical adjustment.
• "Creep zone", down looking optics.
• Pet immune (K9-85, DUO K9-85 & DUO AM K9-85 only) up to 38 kg (85lb)
• Optical chamber - sealed for insects.
• A TEST input permits switching the detector to walk-test mode remotely,
without removing the front panel.
• Microprocessor-controlled.
• 1 or 2 consecutive motion events trigger an alarm (selected by a jumper).
• The NEXT PLUS K9-85 is similar to NEXT PLUS PIR, but with Target
Specific Imaging™ (TSI) for distinguishing between human beings and
pets - it is immune to pets weighing up to 35 kg (85lb).
• The NEXT PLUS DUO K9-85 is similar to NEXT PLUS DUO, but with Target
Specific Imaging™ (TSI) for distinguishing between human beings and
pets - it is immune to pets weighing up to 38 kg (85lb).
• The NEXT PLUS DUO AM uses MW (microwave) adaptable to the protected
area by a range selector and includes anti-masking feature.
• The NEXT PLUS DUO AM K9-85 is similar to NEXT PLUS DUO AM but with
Target Specific Imaging and is immune to pets weighing up to 38 kg (85lb).
2. SPECIFICATIONS
Input Voltage: 9 to 16 VDC
Max. STBY Current Drain @ 12 VDC: 9 mA (PIR & K9-85)
22 mA (DUO, DUO K9-85, DUO AM & DUO AM K9-85)
Selectable Ranges (DUO, DUO K9-85 , DUO AM & DUO AM K9-85 only): 5,
10 and 15m (16, 32 and 49 feet)
Motion Detection Indication:
MODEL EVENT LED indication
DUO
DUO K9-85
DUO AM
DUO AM K9-85
OPTICAL
Coverage Pattern: see fig. 2
Lens Data
No. of beams/curtains:
PIR/DUO/DUO-AM:: 18 far, 18 mid, 10 close.
K9-85/DUO K9-85/DUO AM K9-85: 18 far, 18 mid, 18 close.
Max. Coverage: 15 x 15 m (49 x 49 ft) / 90°
MW SECTION (DUO, DUO K9-85, DUO AM & DUO AM K9-85 only)
Oscillator Type: Microstrip, DRO-stabilized
Frequency: 2.45 GHz
Detection Range: Up to 15 m
ALARM and TAMPER
Alarm Output: Solid-state relay, N.C., up to 100 mA / 30 V, ~30 Ω internal
resistance. Circuit opens for 2-5 sec. upon alarm.
Event Counter: Selectable, 1 or 2 motion events
Tamper Contacts: Normally closed, 50 mA resistive / 30 VDC
TRB Output (DUO-AM and DUO AM K9-85 only): Open collector with
39 KOhm pull up resistor, 50mA max.
MOUNTING
Surface or corner, at the height of 1.8 to 2.4 m (6 to 8 ft). Recommended height for
K9-85 & DUO K9-85 AM 1.8 - 2.1m (6 - 7ft)
Note: Base allows single-sided corner mount at 45° to wall.
ACCESSORIES
BR-1: Surface mounted swivel bracket, adjustable 30° down and 45° left/45° right
BR-2: BR-1 with a corner adapter
BR-3: BR-1 with a ceiling adapter
ENVIRONMENTAL
Operating Temperature: –10°C to 50°C (14°F to 122°F)
Storage Temperature: –20°C to 60°C (–4°F to 140°F)
RFI Protection: Greater than 20 V/m (20 MHz to 2000 MHz)
Compliance with Standards: EN 50131-1 Grade 2, Class II
D-300057 1
Installation instructions for PIR, Pet-Immune, Dual technology PIR/MW, PetImmune Dual Technology PIR/MW, Dual technology PIR/MW Anti-Masking, PetImmune Dual technology PIR/MW anti-masking Detectors.
Instrucciones de instalación de Detectores PIR, inmune a mascotas, Doble
tecnología PIR/MW, Doble tecnología PIR/MW inmune a mascotas, Doble
tecnología PIR/MW anti-enmascaramiento, Doble tecnología PIR/MW antienmascaramiento e inmune a mascotas
Instruções de instalação dos Detectores PIR, imune a animais, Dupla tecnologia
PIR/MO, Dupla tecnologia imune a animais PIR/MO; Dupla tecnologia PIR/MO antimáscara, Dupla tecnologia PIR/MO anti-máscara imune a animais.
PHYSICAL
Size (H x W x D): 94.5 x 63.5 x 49.0 mm (3-11/16 x 2-1/2 x 1-15/16”)
Weight: PIR, K9-85: 50g (1-3/4 oz) approx.
DUO K9-85 AM & DUO AM: 63g (2-1/5 oz)
PATENTS
U.S. Patents 5,693,943 z 6,211,522 z D445,709 (other patents pending)
The DUO, DUO K9-85, DUO AM DUO AM K9-85 comply with the essential
requirements and provisions of Directive 1999/5/EC of the European
Parliament and of the Council of 9 March 1999 on radio and
telecommunications terminal equipment.
2.45 GHz has no restriction in any EU member state.
3. INSTALLATION
3.1 General Guidance (see fig. 3)
1. Keep away from heat sources.
2. Do not expose to air drafts.
3. Do not install outdoors.
4. Avoid direct sunshine.
Additional Guidelines for DUO, DUO K9-85, DUO AM & DUO-AM K985 Detectors
A. Microwave radiation passes through glass and non-metallic walls. Be sure,
therefore, to select the correct range in accordance with the room size. This is
important to minimize the effect of movements occurring beyond room limits
which might cause the MW section to trip.
B. Large reflecting objects (especially metals) in the coverage area can distort
the microwave detector's coverage pattern.
C. If two DUO units are installed in the same room or on opposite sides of a
shared wall, they should not face each other and must be mounted at least
20 cm (0.6 ft) apart.
CAUTION! To prevent nuisance masking alerts of DUO-AM, do not install it near
Power up Red flashes PIR / K9-85
Alarm Red light (2-5 sec.)
Power up Green & red flash alternately
PIR detection Orange light (2-5 sec.)
MW detection Green light (2-5 sec.)
PIR & MW (=alarm) Red light (2-5 sec.)
AM (mask detected) Orange flashes
doors or in narrow corridors, or in any other area where inadvertent approach to
less than 1 meter (3 ft) from the detector is likely to occur.
3.2 Installation Procedure
1. Mounting - see fig. 4.
2. Jumpers settings - see fig. 5.
3. Wiring - see fig. 6.
4. Walk-test the coverage area - see fig. 2. Walk across the far end of
coverage pattern in both directions. The LED should light for 2-5 seconds
each time your motion is detected.
Important! Instruct the user to walk test at least once a week to verify
proper operation of the detector.
4. SPECIAL COMMENTS
Even the most sophisticated detectors can sometimes be defeated or may fail to
warn due to: DC power failure / improper connection, malicious masking of the
lens, tampering with the optical system, decreased sensitivity in ambient
temperatures close to that of the human body and unexpected failure of a
component part. The above list includes the most common reasons for failure to
detect intrusion, but is by no means comprehensive. It is therefore
recommended that the detector and the entire alarm system be checked
weekly, to ensure proper performance.
An alarm system should not be regarded as a substitute for insurance. Home
and property owners or renters should be prudent enough to continue insuring
their lives and property, even though they are protected by an alarm system.
This device has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in residential
installations. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio and television reception. However, there is
no guarantee that interference will not occur in a particular installation. If this
device does cause such interference, which can be verified by turning the
device off and on, the user is encouraged to eliminate the interference by one
or more of the following measures:
– Re-orient or re-locate the receiving antenna.
GB/US: Walk-Test LED
SP: LED de modo de pruebas
PT: LED do teste de passagem
GB/US: Lens
SP: Lente
PT: Lente
Fig. 1 - NEXT PLUS
5. Keep wiring away from power
cables.
6. Do not install behind partitions.
7. Mount on solid stable surface.
Important! The K9-85, DUO K9-85 & DUO AM K9-85
detectors are immune to 38 kg (85 lb) animals moving on
the floor or climbing on furniture as long as the activity
takes place below 1 m (3 ft). Above the 1 m (3 ft) height
limit, the detector is immune to 19 kg (42 lb) pets, but the
pet immunity will decrease as the pet gets closer to the
detector. It is therefore recommended to select a mounting
location that minimizes potential close proximity of animals.
– Increase the distance between the device and the receiver.
– Connect the device to an outlet on a circuit different from the one that
supplies power to the receiver.
– Consult the dealer or an experienced radio/TV technician.
WARNING! Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
W.E.E.E. Product Recycling Declaration
For information regarding the recycling of this product you must contact the
company from which you orignially purchased it. If you are discarding this product
and not returning it for repair then you must ensure that it is returned as identified
by your supplier. This product is not to be thrown away with everyday waste.
Directive 2002/96/EC Waste Electrical and Electronic Equipment.
ESPAÑOL
1. CARACTERÍSTICAS
• La combinación de óptica cilíndrica y Fresnel mejora el rango de detección y
la inmunidad ante falsas alarmas.
• El algoritmo avanzado patentado True Motion Recognition (TMR) reduce
las falsas alarmas.
• Fácil instalación, sin necesidad de ajuste vertical.
• Óptica de vigilancia de la “zona de rastreo".
• Inmune a animales (sólo K9-85, DUO K9-85 & DUO AM K9-85) por
encima de 35 kg (85lb).
• Cámara óptica- sellada contra insectos.
• Una entrada de TEST permite conmutar el detector al modo de test
remotamente, sin necesidad de abrir la carcasa.
• Controlado por microprocesador.
• 1 o 2 eventos de movimiento consecutivos hacen saltar una alarma
(selección mediante un jumper).
• El NEXT PLUS K9-85 es similar al NEXT PLUS PIR, pero con Target
Specific Imaging™ (TSI) para distinguir entre seres humanos y
mascotas- Es immune a mascotas que pesen más de 35 kg (85lb).
• El NEXT PLUS DUO K9-85 es similar al NEXT PLUS DUO, pero con Target
Specific Imaging™ (TSI) para distinguir entre seres humanos y
mascotas- Es immune a mascotas que pesen más de 35 kg (85lb)
• El NEXT PLUS DUO AM es similar al NEXT PLUS DUO pero tiene
característica anti-enmascaramiento.
• El NEXT PLUS DUO AM K9-85 es similar al NEXT PLUS DUO pero usa
Target Specific Imaging y es immune a mascotas que pesen más de 35 kg
(85lb).
2. ESPECIFICACIONES
Alimentación: De 9 a 16 VCC
Max. Consumo de corriente STBY @ 12 VCC: ~9 mA (PIR y K9-85)
Rangos seleccionables (sólo DUO, DUO K9-85 , DUO AM & DUO AM K9-85):
5, 10 y 15 m
Indicación de detección de movimiento:
MODELO EVENTO Indicación LED
DUO
DUO K9-85
DUO AM
DUO AM K9-85
ÓPTICAS
Modelo de cobertura: vea figura 2.
Datos de lente
Nº haces de cortina:
PIR/DUO/DUO-AM: 18 lejos, 18 zona media, 10 cerca.
K9-85/DUO K9-85/DUO AM K9-85: 18 lejos, 18 zona media, 18 cerca.
Max. Cobertura: 15 x 15 m. / 90°
SECCION MICROONDAS (Sólo DUO, DUO K9-85, DUO AM & DUO AM K9-85)
Tipo de oscilador: Microstrip, estabilizado-DRO
Frecuencia: 2.45 GHz
Rango de detección: Hasta 15 m.
Indicación de disparo: El indicador luce VERDE durante 3 seg.
ALARMA y TAMPER
Salida Alarma: relé estado-sólido, N.C., máximo 100 mA / 30 V, ~30 Ω
impedancia. Circuito abierto por 2-5 seg. en alarma.
Contador Eventos: Seleccionable, 1 ó 2 eventos
ContactosTamper: Normalmente cerrados, 50 mA / 30 VDC
Salida TRB (Sólo DUO-AM and DUO AM K9-85): Colector abierto 39
KOhm, 50mA max.
MONTAJE
Superficie o esquina, a una altura de 1.8 a 2.4 m.
Altura recomendada para el K9-85 y DUO K9-85 desde 1.8 hasta 2.1m.
Nota: La base permite el montaje en unos de los lados de una esquina a 45° de la
pared.
ACCESSORIOS
BR-1: Rótula de giro para montaje en superficie, ajustable 30° para abajo y 45°
izquierda/45° derecha.
BR-2: BR-1 con adaptador de esquina
BR-3: BR-1 con adaptador de techo
MEDIOAMBIENTAL
Temperatura de funcionamiento: De –10°C a 50°C
Temperatura de almacenamiento: De –20°C a 60°C
Protección RFI: mayor de 20 V/m (De 20 MHz a 2000 MHz)
Cumplimiento de normas: EN 50131-1 Grado 2 Clase II
FÍSICOS
Tamaño (Al x An x Pr): 94.5 x 63.5 x 49.0 mm
Peso: PIR, K9-85: 50g aprox. DUO, DUO K9-85: 63g
PATENTES
: Patentes U.S. 5,693,943 z 6,211,522 z D445,709 (otras patentes pendientes)
2 D-300057
~22 mA (DUO, DUO K9-85, DUO AM & DUO AM K9-85)
Al Conectar Aliment. Rojo parpadea PIR / K9-85
Alarma Rojo luce (2-5 seg.)
Al Conectar Aliment. Green & red flash alternately
PIR detección Naranja luce (2-5 seg.)
MW detección Verde luce (2-5 seg.)
PIR & MW (=alarma) Rojo luce (2-5 seg.)
AM (detección AM) Naranja flashea
de 1999 de equipamiento de radio y de telecomunicaciones. 2.45 GHz no tiene
ninguna restricción en ningún estado miembro de la UE.
3. INSTALACION
3.1 Consejos generales (vea fig. 3)
1. Situelo lejos de fuentes de calor.
2. No coloque cerca de corrientes
de aire.
3. No instale en exterior.
4. Evite la luz solar directa.
Directrices adicionales para DUO, DUO K9-85, DUO AM & DUO-AM K9-85
A. La radiación de microondas atraviesa el cristal y las paredes no metálicas,
asegúrese de seleccionar el rango correcto acorde con las dimensiones de
la habitación. Esto es importante con el fin de minimizar el efecto de
movimientos que ocurran fuera de los límites de la habitación, lo cuál
podría causar un cambio en la franja de MW.
B. Los objetos muy reflectivos (especialmente metales) que estén en el área
de cobertura pueden distorsionar el patrón de cobertura del detector de
microondas.
C. Si dos unidades DUO están instaladas en la misma habitación o en lugares
opuestos de la misma pared, ellos no deberían verse el uno al otro y deben
estar separados por al menos 20 cm.
¡CUIDADO! Para evitar alarmas de enmascaramiento molestas del DUO-AM, no
lo instale cerca de puertas o en pasillos estrechos, o en cualquier otra área donde
es probable que involuntariamente el detector se aproveche menos de 1m.
İImportante! El K9-85, DUO K9-85 & DUO AM K9-85 son
inmunes a animales de hasta 38 kg que se muevan en el
suelo o trepando sobre muebles siempre que la actividad
se realice por debajo de 1 m. Por encima de la altura límite
de 1 m, el detector es inmune a mascotas de 19 kg, ya que
la inmunidad a mascotas disminuirá cuando la mascota se
encuentre más cerca del detector. Se recomienda por tanto
seleccionar una posición de montaje que minimice la
potencial proximidad de los animales.
3.2 Procedimiento de instalación
1. Montaje - vea fig. 4.
2. Configuración de jumpers - vea fig. 5.
3. Cableado - vea fig. 6.
4. Area de cobertura del test de andado - vea fig. 2. camine a lo largo del final
del modelo de cobertura en ambas direcciones. El LED debería lucir
durante 2-3 segundos cada vez que sea detectado su movimiento.
¡Importante! Instruya al usuario a realizar el test de andado al menos una
vez a la semana para verificar el correcto operación del detector.
5. Mantenga el cableado lejos de
cables de tensión.
6. No instale detrás de particiones.
7. Monte sobre superficie estable y
sólida.
4. COMENTARIOS ESPECIALES
Incluso los detectores más sofisticados pueden ser saboteados algunas veces
o pueden fallar para advertir de: fallo de alimentación de CC / conexión
incorrecta, enmascaramiento malicioso de la lente, sabotaje del sistema óptico,
sensibilidad disminuida en temperaturas ambiente cercanas a las del cuerpo
humano y fallo inesperado de un componente.
La lista de arriba incluye las razones más comunes de fallo para detectar
intrusión, pero no es exhaustivo. Se recomienda por tanto que el detector y el
sistema de alarma completo se compruebe semanalmente, para asegurar su
correcto funcionamiento.
Un sistema de alarma no debería ser considerado como un sustituto del seguro.
Los dueños del hogar y de las propiedades o alquilados deberían ser
suficientemente prudentes para continuar asegurando sus vidas y propiedades,
incluso aunque ellos estén protegidos por un sistema de alarma.
Este dispositivo ha sido probado y cumple los límites para un dispositivo digital
Clase B, conforme a la Parte 15 de las normas FCC. Estos límites están
diseñados para proporcionar una protección razonable contra interferencia
dañina en instalaciones residenciales. Este equipo genera, utiliza y puede
radiar energía de radiofrecuencia y, si no se usa e instala de acuerdo a las
instrucciones, puede causar interferencias perjudiciales para la recepción de
radio y televisión. Sin embargo, no hay garantía que las interferencias no
puedan producirse en una instalación concreta. Si este dispositivo produce
tales interferencias, lo que se puede comprobar desconectando y conectando
el dispositivo, se anima al usuario a eliminar la interferencia mediante una o
más de las siguientes medidas:
– Reoriente o reubique la antena receptora.
– Aumente la distancia entre el equipo y el receptor.
– Conecte el equipo una toma de corriente diferente del que alimenta al receptor.
– Consulte al vendedor o a un profesional de radio/TV.
¡ADVERTENCIA! Cambios o modificaciones en esta unidad no aprobados
expresamente por la parte responsable puede anular el derecho del usuario
de hacer funcionar este equipo.
Declaración de Reciclaje de Producto R.A.E.E.
Para información relacionada con el reciclaje de este producto debe contactar
con la compañía a la que compró en origen. Si usted va a desechar este
producto y no lo va a devolver para reparación debe asegurar que es devuelto
como estableció su proveedor. Este producto no se tira con la basura diaria.
Directiva 2002/96/EC de Residuos de Aparatos Eléctricos y Electrónicos.