1. INTRODUCTION
1. INTRODUCTION
1. INTRODUCTION1. INTRODUCTION
The PB-101 PG2 and PB-102 PG2 are miniature PowerG
pendants, designed for use with PowerMaster control panels and
other PowerG receivers.
To activate transmission, press the pushbutton(s) at the center of
the unit. When activated, the transmitter sends out an alarm code,
and a buzzer sound and the LED light indicates confirmation about
successful or failed transmission.
The PB-101/102 has several options for carrying or mounting it.
The unit is supplied with a belt clip, a key chain, a lanyard
necklace, and a holder which can be attached to the belt clip or
mounted on a wall.
2.
2. OPERATION
OPERATION
2. 2.
OPERATIONOPERATION
The following functions are available:
Panic
The signal will notify
your central monitoring
station of an emergency
Press and hold the button down for
2 – 7 seconds.
Installation Instructions
Figure 1. PB-101 and PB-102
Press and hold both buttons down
simultaneously for more than 3
seconds.
No activity
Arm
Arm your system in the
Disarm
3. ASSEMBLY FOR
3. ASSEMBLY FOR PORTABILITY AND
3. ASSEMBLY FOR 3. ASSEMBLY FOR
This section describes how to attach the PB-101/102 to various portability options.
WARNING! Choking Hazard; Small parts; The pendant and belt clip are NOT for children under 3 years.
1. Slide the PB-101/102 into the holder until you feel it snap securely
inside.
2. To attach the belt clip, slide it onto the rails on the rear of the
holder.
3. To remove the PB-101/102 from the wall-mounted holder or from
Figure 2 Attaching PB-101/102 to a Belt Clip
---
---
Press and release the button in less
Not applicable
Not applicable
PORTABILITY AND MOUNTING
PORTABILITY AND PORTABILITY AND
MOUNTING
MOUNTINGMOUNTING
the belt clip, press down the top of the holder and push the pendant
up with your fingers.
Figure 4 Attaching PB-101/102 to a Lanyard Necklace
---
Figure 3 Attaching PB-101/102 to a Key Chain
Not applicable
Press and hold this button for less than
7 seconds.
Press and hold this button for less than
D-304457 PB-101/102 User’s Guide 1
This side
1. Using the two screws and plastic anchors included in the PB101/102 box, align the holder facing up and secure the holder to the
wall.
2. Slide the PB-101/102 into the holder until you feel it snap securely
inside.
4444. ENROLLMENT OF PB
. ENROLLMENT OF PB----101/102
. ENROLLMENT OF PB. ENROLLMENT OF PB
The Enrollment process “teaches” the system’s control panel the ID
of the PB-101/102 and enables the PB-101/102 to communicate with
the panel.
1. Enter the PowerMaster panel’s Installer menu and select
“02:ZONES/DEVICES”.
2. Select "ADD NEW DEVICE" Option.
5555. TESTING AND MAINTENANCE
. TESTING AND MAINTENANCE
. TESTING AND MAINTENANCE. TESTING AND MAINTENANCE
Figure 5 Attaching PB-101/102 to a Wall Mount
101/102
101/102101/102
5.1 Testing a New Unit
Since the PB-101/102 is supplied with the battery already
installed, the unit is practically ready to be tested.
IMPORTANT! Before testing, enroll the PB-101/102 in the
target control panel as instructed in the panel’s
programming instructions.
1. Stand 3 m (10 ft) away from the control panel and press the
buttons. Verify that the transmit LED lights.
2. Make sure that the control panel responds as programmed and
3. To remove the PB 101/102 from the holder, press down the top of
the holder and push the pendant up with your fingers as illustrated in
Figure 2.
3. Stand near the PowerMaster panel. Press and hold the
button (for PB-101) or the left button (for PB-102) until the
yellow LED turns on, and then release the button. Ensure that
the LED stays on for 2 seconds and then flashes for 10
seconds.
as stated in the panel’s programming instructions.
3. Operate the pendant from various locations within the area
covered by the receiver to determine "dead" locations, where
transmission is blocked by walls and large objects, or affected
by structural materials.
Note: If dead/marginal zones are a problem, relocating the
receiver may improve the performance.
5.2 Replacing the Battery
Replace the battery at least once every 5 years, or upon
observing that the LED flickers when transmitting. The required
battery is CR2032 Lithium 3V, manufactured by VARTA or
another UL-recognized manufacturer, purchased from a Visonicapproved supplier.
NOTE: The polarity of the battery must be observed, as
shown in Figure 7. Improper handling of lithium batteries
may result in heat generation, explosion or fire, which may
lead to personal injuries.
WARNING: Danger of explosion if batteries are installed
incorrectly. Replace only with the same or equivalent type
recommended by the manufacturer. Keep away from small
children. If batteries are swallowed, promptly see a doctor.
Do not try to recharge these batteries. Disposal of used
batteries must be made in accordance with the waste
recovery and recycling regulations in your area.
2
1. Insert a coin into the slot on the bottom center of the device
and twist to separate the two sides.
2. Then, slide the coin to the corner of the device and twist again
to remove the cover.
Figure 6. Opening the PB-101/102
Note: Make sure the elastic pad within the cover remains in
place. Put it back in place if it falls off.
D-304457 PB-101/102 User’s Guide