Visonic PB10XPG2 Users Manual

PB
Function
PB-
101 PB-102
situation.
B
utton press is ignored.
than 2 seconds.
Away mode.
Disarm your syst
em.
7 seconds.
PB----101
PBPB
101 PG2 /
PG2 /
PG2 / PG2 /
PB
PB----102
PBPB
102 PG2
PG2
PG2PG2
Wireless Panic Button
1. INTRODUCTION
1. INTRODUCTION
1. INTRODUCTION1. INTRODUCTION
The PB-101 PG2 and PB-102 PG2 are miniature PowerG pendants, designed for use with PowerMaster control panels and other PowerG receivers. To activate transmission, press the pushbutton(s) at the center of the unit. When activated, the transmitter sends out an alarm code, and a buzzer sound and the LED light indicates confirmation about successful or failed transmission. The PB-101/102 has several options for carrying or mounting it. The unit is supplied with a belt clip, a key chain, a lanyard necklace, and a holder which can be attached to the belt clip or mounted on a wall.
2.
2. OPERATION
OPERATION
2. 2.
OPERATIONOPERATION
The following functions are available:
Panic The signal will notify your central monitoring station of an emergency
Press and hold the button down for 2 – 7 seconds.
Installation Instructions
Figure 1. PB-101 and PB-102
Press and hold both buttons down simultaneously for more than 3 seconds.
No activity
Arm
Arm your system in the
Disarm
3. ASSEMBLY FOR
3. ASSEMBLY FOR PORTABILITY AND
3. ASSEMBLY FOR 3. ASSEMBLY FOR
This section describes how to attach the PB-101/102 to various portability options.
WARNING! Choking Hazard; Small parts; The pendant and belt clip are NOT for children under 3 years.
1. Slide the PB-101/102 into the holder until you feel it snap securely inside.
2. To attach the belt clip, slide it onto the rails on the rear of the holder.
3. To remove the PB-101/102 from the wall-mounted holder or from
Figure 2 Attaching PB-101/102 to a Belt Clip
---
---
Press and release the button in less
Not applicable
Not applicable
PORTABILITY AND MOUNTING
PORTABILITY AND PORTABILITY AND
MOUNTING
MOUNTINGMOUNTING
the belt clip, press down the top of the holder and push the pendant up with your fingers.
Figure 4 Attaching PB-101/102 to a Lanyard Necklace
---
Figure 3 Attaching PB-101/102 to a Key Chain
Not applicable
Press and hold this button for less than 7 seconds.
Press and hold this button for less than
D-304457 PB-101/102 User’s Guide 1
This side
facing up
1. Using the two screws and plastic anchors included in the PB­101/102 box, align the holder facing up and secure the holder to the wall.
2. Slide the PB-101/102 into the holder until you feel it snap securely inside.
4444. ENROLLMENT OF PB
. ENROLLMENT OF PB----101/102
. ENROLLMENT OF PB. ENROLLMENT OF PB
The Enrollment process “teaches” the system’s control panel the ID of the PB-101/102 and enables the PB-101/102 to communicate with the panel.
1. Enter the PowerMaster panel’s Installer menu and select “02:ZONES/DEVICES”.
2. Select "ADD NEW DEVICE" Option.
5555. TESTING AND MAINTENANCE
. TESTING AND MAINTENANCE
. TESTING AND MAINTENANCE. TESTING AND MAINTENANCE
Figure 5 Attaching PB-101/102 to a Wall Mount
101/102
101/102101/102
5.1 Testing a New Unit
Since the PB-101/102 is supplied with the battery already installed, the unit is practically ready to be tested.
IMPORTANT! Before testing, enroll the PB-101/102 in the target control panel as instructed in the panel’s programming instructions.
1. Stand 3 m (10 ft) away from the control panel and press the
buttons. Verify that the transmit LED lights.
2. Make sure that the control panel responds as programmed and
3. To remove the PB 101/102 from the holder, press down the top of the holder and push the pendant up with your fingers as illustrated in Figure 2.
3. Stand near the PowerMaster panel. Press and hold the
button (for PB-101) or the left button (for PB-102) until the yellow LED turns on, and then release the button. Ensure that the LED stays on for 2 seconds and then flashes for 10 seconds.
as stated in the panel’s programming instructions.
3. Operate the pendant from various locations within the area covered by the receiver to determine "dead" locations, where transmission is blocked by walls and large objects, or affected by structural materials.
Note: If dead/marginal zones are a problem, relocating the
receiver may improve the performance.
5.2 Replacing the Battery
Replace the battery at least once every 5 years, or upon observing that the LED flickers when transmitting. The required battery is CR2032 Lithium 3V, manufactured by VARTA or another UL-recognized manufacturer, purchased from a Visonic­approved supplier.
NOTE: The polarity of the battery must be observed, as shown in Figure 7. Improper handling of lithium batteries may result in heat generation, explosion or fire, which may lead to personal injuries.
WARNING: Danger of explosion if batteries are installed incorrectly. Replace only with the same or equivalent type recommended by the manufacturer. Keep away from small children. If batteries are swallowed, promptly see a doctor. Do not try to recharge these batteries. Disposal of used batteries must be made in accordance with the waste recovery and recycling regulations in your area.
2
1. Insert a coin into the slot on the bottom center of the device and twist to separate the two sides.
2. Then, slide the coin to the corner of the device and twist again to remove the cover.
Figure 6. Opening the PB-101/102
Note: Make sure the elastic pad within the cover remains in
place. Put it back in place if it falls off.
D-304457 PB-101/102 User’s Guide
Loading...
+ 2 hidden pages