1. INTRODUCTION
The Next CAM PG2 is a 2-way, microprocessor-controlled, wireless digital PIR detector with integrated camera and microphone for alarm verification. Activated upon PIR detection or upon demand, the Next CAM PG2 sends clear images with optional audio to the Monitoring Station. It thus enables accurate status assessment of the premises.
The PIR detector's features are as follows:
Up to 12 meters (40 ft).
90° angle camera overlaps PIR field of view
10 meter (33 ft) range in complete darkness overlaps PIR rangge
Wall creep zone protection.
For pet immune version - Target Specific Imaging™ (TSI)
technology is used for distinction between human beings and pets weighing up to 38 kg (85lb).
Includes a fully supervised PowerG transceiver.
True Motion Recognitionalgorithm.
Built-in link quality indicators; no need for the installer to
physically approach the control panel thus making installation faster and easier.
No vertical adjustment is needed.
Temperature compensation.
Sealed chamber protects the optical system from insects.
Front cover and back tamper, for improved tamper protection.
White light protection.
The camera's features are as follows:
Optional AC power
Up to 10 cameras
Optional audio with images for listen -in
Images multiplexed from all cameras
Color and back & white images
Auto-setup (brightness, contrast)
Camera tuning by simple walk-test
Day and night CMOS camera, with IR illumination. This allows
taking pictures in full darkness without letting the intruder know.
Instant capture: guarantees capture of fast moving intruder.
Camera operation modes:
o Post alarm – pictures are taken after detection by
detector.
o On demand – pictures are taken after a command from
the monitoring station.
An event records 2 images per second. 10-15 images total (can be customized by request)
Works with repeaters for extended range
A. Microphone B. Camera lens C. IR LED D. Light sensor
E. LEDs
Installation Instructions
B
C
D
A
Fig. 1. External View
E
2. SPECIFICATIONS
GENERAL Detector Type: Dual element low-noise pyroelectric sensor Lens Data: No. of Curtain Beams / curtains:
Next CAM PG2: 18 far, 18 mid, 10 close. Next CAM-K9 PG2: 18 far, 18 mid, 18 close.
Max. Coverage: 12 x 12 m, (40 x 40 ft) / 90° Pet Immunity (Next CAM-K9 PG2 only): Up to 38 kg (85 lb).
ELECTRICAL Internal Battery or two CR17450 3V batteries, in series) or equivalent.
Note: For UL installations use Panasonic, Sanyo, GP or Varta only. Use only the above battery. Dispose of used battery according to the manufacturer's instructions.
Nominal Battery Capacity: 6V 1450 mA/h (2xCR123A), 2200 mA/h (2xCR17450)
Battery Life (for typical use): 4 to 5 years (CR123A) / 8 years (CR17450).
Optional MAINS supply: Additional to batteries, 7.5 V DC. Power Supply: Type C
FUNCTIONAL True Motion Event Verification: 2 remote selections - 1 (OFF)
or 2 (ON) motion events IR Illumination: 10 m (33 ft)
: 6V Lithium battery (two CR-123A 3V batteries
D-302893 1
Picture Resolution: 320x240 pixels QVGA Frame Rate: up to 2 fps (for user) Alarm Period: 2 seconds
A. TOP VIEW B. SIDE VIEW C. Next CAM PG2: 0.5-
4m, Next CAM-K9 PG2: 2-4m
9 (30ft)
6 (20ft)
A
3 (10ft)
0
3 (10ft)
6 (20ft)
9 (30ft)
2.4 m
B
(8 ft)
C
Fig. 2. Coverage Pattern & Walk-test
90°
36 12 m0
10 20 30 40 ft
36912 m0
10 20 30 40 ft
9
WIRELESS
A
D
N
D
E
L
E
A
D
L
Frequency Band (MHz): Europe: 433, 868, USA: 915 Communication Protocol: PowerG Supervision: Signaling at 4-min. intervals Tamper Alert: Reported when a tamper event occurs and in any
subsequent message, until the tamper switch is restored
MOUNTING Height: 1.8 - 2.4 m (6 - 8 ft). For Next CAM-K9 PG2, the
recommended height is up to 2.1 m (7 ft) Installation Options: Surface or corner ACCESSORIES
BR-1: Surface mounted swivel bracket, adjustable 30° down and 45° left/45° right. BR-2: BR-1 with a corner adapter BR-3: BR-1 with a ceiling adapter
ENVIRONMENTAL RFI Protection: >20 V/m up to 2000 MHz, excluding inband
frequencies Operating Temperatures: -10 Storage Temperatures: -20 Humidity: Average relative humidity of approximate up to 75%
non-condensing. For 30 days per year relative humidity may vary between 85 % and 95 % non-condensing.
Compliance with Standards: USA: Designed to meet FCC Part 15 Europe: Directive 1999/5/EC of the European Parliament. EN
50131-1 Grade 2 Class II. EN 50131-2-2, EN 50131-6
PHYSICAL Size (H x W x D): 125 x 63 x 60 mm (4-15/16 x 2-1/2 x 2-3/8”). Weight (with battery): 200 g (7 oz). Color: White
PATENTS
U.S. Patents 5,693,943 z 6,211,522 z D445,709 (another patent pending)
°C to 50°C (14°F to 122°F) indoor
°C to 60°C (-4°F to 140°F).
3. ENROLLMENT
Refer to the control panel Installer Guide for the device enrollment procedure.
4. Next CAM PG2 / Next CAM-K9 PG2 DEVICE SETTINGS
This section describes how to configure the parameters of the PIR detector from the control panel.
To Modify the PIR Detector Device Settings
Refer to the control panel Installer Guide and perform the procedure for Adding A Wireless Device (section 4.5.2), or, Modifying a Device (section 4.5.5). Then continue below to modify the device settings.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
EV SETTINGS
larm LED
ED ON 
or
larm LED
vent Counter
ED Sensitive 
or
vent Counter
ISARM Activity
OT Active 
or
ISARM Activity
Here you determine whether or not the alarm LED indication will be activated.
Select between "LED ON" and "LED OFF".
Here you determine whether an alarm will be activated upon continued motion (low sensitivity) or upon a single alarm event (high sensitivity).
Select between "LOW sensitive" and "HIGH sensitive".
Here you set the activity time during disarm.
Select between "NOT Active", "YES – no delay", "YES + 5s delay", "YES + 15s delay", "YES + 30s delay", "YES + 1m delay", "YES + 2m delay", "YES + 5m delay", "YES + 10m delay", "YES + 20m delay" and "YES + 60m delay".
2 D-302893