Visonic MP862PG2 Users Manual

D
A
B
C
E
D-307080
MP-862
Wireless ceiling PIR presence/security detector
Installation Instructions

1. Introduction

The MP-862 is a smart wireless ceiling PIR presence/security detector (selected mode) that creates a 360° coverage area to detect the move­ment of intruder s in indoor areas. The detector has the following features.
l Presence detection mode - active 15 minutes after installation (power-up).
l Built-in link quality indicators eliminate the need for the installer to physically approach the control panel and reduce installation time.
l Temperature and light measurement and reporting.
l PowerG two-way Frequency Hopping Spread Spectrum FHSS-TDMA technology.
l The Advanced True Motion Recognition™ algorithm (patented)distinguishes between the tr ue motion of an intruder and any other disturbances
which may cause false alarms.
NOTE: For UL installations, the detector isfor use with UL listed control unitsonly.
A Tamper protection
B Light sensor
C Pyro sensor
D Battery
E LEDs
Fig ure 1. Internal view

2. Installation

2.1. Installation tips
Use the following as a guide for locating a suitable mounting location.
1. Keep away from heat sources.
2. Do not expose to air drafts.
3. Do not install outdoors.
4. Avoid direct sunshine.
5. Do not install near high voltage electricallines.
6. Do not install behind partitions.
7. Mount on a solid stable surface.
Fig ure 2. Gen eral Guid elin es
WARNING! Do not partially or completely obscure the detector’s field of view. WARNING! T o comply with FCC and ISED Canada RF exposure compliance requirements, the PIR detector should be located at a distance of at least 20 cm from all persons during normal operation. The antennas usedfor this product must not be co-located or operated in conjunction with any other antenna or transmitter .
NOTE: The MP-862 Wireless ceiling PIR presence/securitydetector shall be installed and used within an environment that provides the pollution degree max 2 and overvoltages category II in NON HAZARDOUS LOCATIONS. The equipment is designed to be installed only by qualified ser­vicepersons.
D-307080 MP-862 Installation Instructions 1
NOTE: MP-862 shall be installed in accordance with the Standard for Installation and Classification of Burglar and Holdup Alarm Systems, UL
681.
2.2. Inserting or replacing the battery
If the battery isalready installed, pull the activation strip that protrudes from the back of the detector.
1. To separate the detector from the mounting bracket, rotate the bracket anticlockwiseand pullit fr om the detector.
2. Insert the battery while observing polarity.
3. Align the bracket tabs with the detector slots and rotate the detector clockwise to verify that it is securely attached.
Fig ure 3. Removing the bracket
NOTE: It is recommended to wait about 1 minute after battery removal before inserting the new battery. Caution! Risk of explosion if battery is replaced byan incorr ect type. Dispose of used batteries according to the manufacturer's instructions and
according to localrules and regulations.
2.3. Enrollment
Refer to the PowerMaster panel’s installer guideand follow the procedure under the “02:ZONES/DEVICES” option of the Installer Menu.
NOTE: For UL/ULC listed installations use onlyin conjunction with UL/ULC listed control panels: PowerMaster-10 and PowerMaster-30 PG2. To enroll the device enter the Installation menu and do as follows:
1. From the Installation menu, select 02:ZONES/DEVICES and click OK.
2. Select ADD NEW DEVICES and click OK. Panel displays: <ENROLL NOW or ENTER ID:xxx-xxxx>
3. Enter ID:XXX-XXXX (the number of the device that isprinted on the label), -OR- insert the battery to power on the device.
4. To change the Zone/Devicenumber, click the arrow button or type the zone number and then click OK.
5. To configure the location, zone type and chime parameters, select Z14.LOCATION, Z14.ZONE TYPE and Z14.SET CHIME and select desired settings.
6. Select one of the following options.
a. Continue to configure the device.
b.
Select and then clickOK to exit.
2.4. Walk testing
Before permanently mounting any wireless device,temporarily mount the device and perform a walktest. Perform a walktest of the coverage area at least oncea year to ensure that the detector is working corr ectly. After inserting the battery or closingthe device, the detector will automatically enter a stability period where the LED flashes RED for 90 seconds. Walk test the coverage area, the LED lights red each time your motion isdetected followed by3 LED blinks. The color of the 3 LED blinks indicate the received signal strength. In walk-test mode, regardless of the LED Selection status, the LED lights upon every motion detection. After 15 minutes the detector automatically enters normal mode. The following table indicates the received signal strength.
LED Response Signal Strength
Green LED blinks STRONG
Orange LED blinks GOOD
Red LED blinks POOR
No blinks No communication
IMPORTANT! Only GOOD or STRONG signalstrengths are acceptable. If you receive a POOR signal from the device, re-locate it and re-test until a GOOD or STRONG signal isr eceived.
NOTE: For UL/ULC installations, onlySTRONG signal levels are acceptable. After installation verify the product functionality in conjunction with the compatible control panels PowerMaster-10 and PowerMaster-30 PG2.
NOTE: For detailed Placement instructions refer to the control panel reference manual.
Walk-test the cover age area by walking across the far end of the coverage pattern in both directions. T he red LED lights each time your motion is
detected followed by a steady LED signal strength indication.
2.5. Mounting the device
1. Mark and dr illtwo holes in the mounting surface. If you install tamper protection on the detector, mark and drill one hole for the tamper pro­tection and one hole for one of the other available slots.
2. Fasten the bracket to the mounting surface with the two screws.
3. Align the br acket tabs with the detector slots and rotate the detector clockwise. Verify that it is securely attached.
4. Fasten the detector to the br acket with the screw.
D-307080 MP-862 Installation Instructions 2
A
B
Fig ure 4. F ast ening the b racket
D
E
C
A Tamper protection
B Bracket screw slots
C Isolation strip
D Bracket tabs
E Detector slots
Fig ure 6. F ast ening the d et ector
The following table outlines the detection distance in relation to the mounting height.
Height 2 m 3 m 4 m
Detection distance 3.1 m 3.75 m 5 m
2.6. LED Operation
LED Indications Event
Red LED blinks Stabilization (war m- up 90 seconds)
Red LED on 0.2 seconds T amper open/close
Red LED on 2 seconds Intruder alarm

3. Temperature display

Fig ure 5. Att ach ing the detect or

4. Configuring the Detector Parameters

Enter the DEVICE SETTINGS menu and follow the configur ation instructions for the deviceas described in the following table.
Option Con fig uring Instructions
Alarm LED Define whether or not the alarm LED indication will be activated. Optional settings: LED ON (default) and LED OFF .
Event Counter
DISARM Activity
VERY HOT > 35°C [ >95°F]
COLD < 19°C [ <66°F]*
FREEZING < 7°C [ <45°F]*
FREEZER >
-10°C [ <14°F]*
NOTE: The temperature mustpass beyond the threshold for the required duration in order to generate an alarm or restore transmission.
NOTE: The user can giveaccess to installer to remotely enable or disable the indication LED.
Define whether an alarm willbe activated upon continued motion (low sensitivity) or upon a single alarm event (high sensitivity). Optional settings: LOW sensitive (default) and HIGH sensitive.
Define whether or not to set the activity time during disarm. Optional settings: NOT Active (default), YES – no delay, YES+ 5s delay, YES + 15sdelay, YES + 30s delay, YES + 1m delay,YES + 2m delay, YES+ 5m delay, YES + 10m delay,YES + 20m delay and YES+ 60m delay.
Define whether or not the control panel willrepor t a "very hot" alert when the temper ature risesabove 35°C (95°F) for at least 10 minutes. Alert restor e willoccur when the temperature drops below 34°C ( 93°F) for the duration of 10 minutes. Optional settings: Disable (default) or Enable
Define whether or not the control panel willrepor t a "cold" alert when the temper ature drops below 19°C (66°F) for at least10 minutes. Alert restor e willoccur when the temperature rises above 20°C (68°F) for the duration of 10 minutes. Optional settings: Disable (default) or Enable
Define whether or not the control panel willrepor t a "freezing" alert when the temperatur e drops below 7°C (45°F) for at least 10 minutes. Alert restor e willoccur when the temperature rises above 8°C (48°F) for the duration of 10 minutes. Optional settings: Dis­able (default) or Enable
Define whether or not the control panel willrepor t a "freezer" alert when the temperature risesabove -10°C (14°F) for at least 30 minutes. Alert restor e willoccur when the temperature drops below -11°C (12°F) for the duration of 10 minutes. Optional settings: Disable (default) or Enable
D-307080 MP-862 Installation Instructions 3
Loading...
+ 5 hidden pages