Operation
1. Opening the door/window to separate the magnet from the sensor will send the status of “Open” to the Z-Wave Interface Controller, and the LED will flash once.
2. Closing the door/window to align the magnet with the sensor will send the status of “Closed” to the Z-Wave Interface Controller, and the LED will flash once.
3. Normal operation, the LED will not light.
4. The ZD2102 sensor equipped with tamper switch. If the cover of sensor is removed, the door sensor will report a zone tamper to the Z-Wave Interface Controller, and the LED will go solid.
Federal Communications Commision Statement
This equipment has been tested and found to comply with the limi ts for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. Howeve, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interferene by one of the following measures:
- Reorient or relocate the receiving antenna,
- Increase the separation between the equipment and receiver,
- Connect the equipment into and outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undersired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
Limited Warranty
Vision Guarantees that every wireless door/window sensor is free from physical defects in material and workmanship under normal use for one year from the date of purchase. If the product proves defective during this one-year warrany period, Vision will replace it free of charge. Vision does not issue any refunds. This warnnty is extended to the original end user purchase only and is not transferable. This warranty does not apply to : (1) damage to units caused by accident, dropping or abuse in handling, or any negligent use; (2) units which h ave been subject to unauthorized repair, opened, taken apart, or otherwise modified; (3) units not used in accordance with instruction; (4) damanges exceeding the cost of the produt; (5) transit damage, initial installation costs, removal cost, or reinstallation cost. For information on addional devices, plesae visit us at www.visionsecurity.com.tw
ZD 2102 V0 20101013 6B1Z-21001
-3-
Installation & Operation Manual
ZD 2102 EU ZD 2102 US ZD 2102 AU
ZD 2102 JP
Wireless Door/ Window Sensor
Page 2
Introduction
Thanks for choosing the Vision’s wireless door/window sensor of the home security device.
This sensor is a Z-W ave enabled device (interoperable, two-way RF mesh networking
technology) and is fully compatible with any Z-Wave enabled network. This sensor
monitors door/window and send Z-Wave signal when door or window is opened and closed.
Every Z-Wave enabled device acts as a signal repeater and multiple devices result in more
possible transmission routes which helps eliminate “RF dead-spots”.
Product Description and Specification
*** For indoor use only***
Specification: Package Content:
Protocol: Z-Wave (ZM3102N) Frequency Range:
868.42MHz (ZD2102EU)
908.42MHz (ZD2102US)
921.42MHz (ZD2102AU) 951-956MHz (ZD2102JP)
Operating Range: Up to 100 feet line of sight Operating Temp.: -15C~ 60C (5F ~140F)
Battery: Panasonic CR123A * 1PC
1pc 1pc 1pc 2pcs
1pc 4pcs 1pc
ZD 2012 sensor Bracket for Contact Magnet Magnet Adhesive tape for Magnet / sensor CR123A Lithium Battery Screws for bracket/ sensor Installation & Operation manual
Installation
Notice: If you are installing the entire Z-Wave system for the first time, please refer to the installation guide of Z-Wave Interface Controller you have ordered from other manufacturer before installing ZD2102 Door/Window Sensor.
1. Unscrew the screw fastening the rear cover.
2. Slide the rear cover down.
3.
Using the screws or adhesive tape to affix the rear cover on the frame along the opening edge of door / window.
-1-
4. Using the screws or adhesive tape to affix the rear cover on the frame along the opening edge of door / window.
5. Insert a CR123A battery into the battery compartment, and LED will start to flash slowly, which means the sensor has not yet been “inclusion”
6. For “Inclusion” operation: Put the Z-Wave Interface Controller into “inclusion” mode, and following its instruction to add the ZD2102 to your controller. To g e t i n th e “i n c lu s i on ” m od e , t h e d i s ta n c e b e tw e en sensor and controller is suggested to be in one meter. Press the program switch of ZD2102 for 1 second at least. The LED on the ZD2102 should go solid, if not, please try again.
For “Exclusion” operation: Put the Z-Wave Interface Controller into “exclusion” mode, and following its instruction to delete the ZD2102 to your controller. Press the program switch of ZD2102 for 1 second at least to be excluded.
For “Associations” operation: Put the Z-Wave Interface Controller into “association” mode, and following its instruction to associate the ZD2102 with other device. Please remove the cover of ZD2102 to do association & close back after done. Up to four Z-Wave devices can be associated with ZD2102. ZD2102 will send a simple “on” command to all devices that are associated with it.
7. Slide back the rear cover and screw fastening with the front cover, the LED should go off.
8. Fix the Magnet by using the adhesive tape or fixing screws, locate the Magnet close to the ZD2102 sensor the distance between these two devices should be in 1.9cm.
9. External Switch: If your window need two sensors for fully monitoring. You could use an external switch to connect with the ZD2102 for extending detection. The ZD2102 has 2 normally closed contact terminals. These can be used for additional external switch wired contacts.
-2-
Loading...