Vision VP-240, VP-600 User Manual

NO.007
V Power
VP-240 VP-600
User Manual
VP-240/600
TABLE OF CONTENTS
1. Safety Instruction
2. Features
3. Technical Specification
4. Installing Instructions
5. Main Function
6. Overview
6.1 Front View
6.2 Rear View
7. DMX Controller
8. DMX512 Configuration
9. DMX512 Connection
9.1 XLR Connection
9.2 RJ45 Connection
1A
VP-240/600
1. Safety Introductions
Please read the User Manual carefully as it includes important information regarding
details of operation, maintenance and technical data. Keep this manual with unit for
future consultation.
WARNING
Avoiding any flammable liquids, water or metal objects enter into the unit.
If any liquid spill on the unit, disconnect the power supply immediately.
When serious operation problem happen, stop using the unit immediately and
contact your local dealer for service.
Do not open the unit because there are no user serviceable parts inside.
Never try to repair the unit yourself. Repairs by unqualified people may cause
damage or faulty operation. Please contact your nearest dealer for any service.
CAUTION
After removed the package, make sure the unit is not damaged in any way. Don’t
use it with doubt and contact an authorized dealer.
Never use the unit under the excessive humidity and a temperature over 40℃.
Do not try to dismantle or modify the unit.
2. Features
EC - Declaration of Conformity
We declare that our products (lighting equipments) comply with the
following specification and bears CE mark in accordance with the
provision of the Electromagnetic Compatibility (EMC) Directive
89/336/EEC.
EN55014-2: 1997 A1: 2001, EN61000-4-2: 1995; EN61000-4-3:
2002;
EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6: 1996,
EN61000-4-11: 1994.
&
Harmonized Standard
EN60598-1: 2000+ALL: 2000+A12: 2002
y 7 Channel modes (Mode 1 & Mode 2 for RGBW; Mode 3 &Mode 4 for RGB;
Mode 5 &Mode 6 for CW and WW colors; Mode 7 for single color) enables V
Power to control passive lighting fixtures that fitted with different LED emitters.
y Comes with 3 chase groups, each group has 8 chases (3 editable chases); and
each chase can have up to 42 scenes. For editing the chases, Visio has
developed a software (option) that enables you to edit the chases easily.
2A
VP-240/600
9.2 RJ45 Connection
DMX Input, Output LED module Input
RJ45 Connector RJ45 Connector
Front view of the Connector Front view of the Connector
Pin 1: Not connected Pin 5: Not connected Pin 1: Red LED + Pin 5: Red LED - Pin 2: Not connected Pin 6: Data + Pin 2: Green LED + Pin 6: Green LED - Pin 3: Not connected Pin 7: Data - Pin 3: Blue LED + Pin 7: Blue LED - Pin 4: Not connected Pin 8: GND Pin 4: White LED + Pin 8: White LED -
VP-240/600
y It comes with the built-in clock for editing your shows. You can edit max. 30
shows (choose from the chases) in one week, and different time period per day.
y User can run the chase manually step by step by pressing the manual button. y Excellent fade effect, and auto running function. y LCD display for easy navigation.
3. Technical Specifications
y DMX Input Control: DMX 512 DMX connection: RJ45 or 3 pin XLR
y DMX Output
Max. Power Output: 240W (VP-240) 600W (VP-600) Output Voltage: DC 48V Max. Output Current: 350mA per color Max. Load per zone: RGB & RGBW mode-Each color 12 LEDs max. White mode(warm white & cool white)-Each white 24 LEDs max. Single mode - Total LED 48 max.
y Input Voltage: 100V -240V~50-60Hz y Fuse: T 3.15A (VP-240)
T 6.3A (VP-600)
y Dimension: 280×309×90 mm (VP-240)
440 x 416 x 99 mm (VP-600)
y Weight: 4kgs (VP-240)
5.6kgs (VP-600)
18A
3A
VP-240/600
4. Installing instructions
VP-240/600
9. DMX512 Connection
The VP-240/600 should be placed on a non-flammable flat surface in any orientation and fixed by screws. There are mounting holes on the housing. Ensure that installation place is enough ventilated.
V Power could control the LED fixtures such as V Aqua, V Bar, V Ceiling, V Inground, V Net, V Wall and CW36, the VP-240 power output is 240 watt (4×60W ) and the VP-600 power output is 600 watt (10 x 60W).
4A
9.1 XLR Connection
1. If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin adapter-cable.
2. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+ ) into a 3-pi n XL R-plu g and plug it in the DMX-output of the last unit.
3. Connect the u nit together in a `daisy chain` by XLR plug from the output of the unit to the input of the next unit. The cable can not branched or split to a `Y` cable. DMX 512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down the system.
4. The DMX output and input connectors are pass-through to maintain the DMX circuit, when one of the units’ power is disconnected.
5. Each unit needs to have an address set to receive the data sent by the controller. The address number is between 0-511 (usually 0 & 1 are equal to 1).
6. The end of the DMX 512 system shoul d be terminated to reduce signal errors.
7. 3 pin XLR connectors are more popular th an 5 pin XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
Pin 4/Pin 5: not used.
17A
VP-240/600
4 Channels:
20 Channels:
11 Channels: 10 Channels:
VP-240/600
5. Main Function
To select an y function, press MENU button until the required one is shown on the display. Select the function by ENTER button and the display will blink. Use DOWN and UP button to change the mode. Once the required mode has been selected, press ENTER button to setup. Back to the functions without any change press MENU button.
Press MENU button for 3 seconds to exit the functions, press “Chase Group 1”, “Chase Group 2” or “Chase Group 3” button to run the built-in chas e or you have programmed. Enter chase group, the LED on, then press the chase gr oup button again to choose the chase. Once the chase has been selected, press “Manual” button into manual mode, the LED on, you can choose the step one by one; pr ess “Fade” button into fade mode, the LED on, the unit will run all steps of the chase automatically, at this time, you can press UP/DOWN button to adjust the fade time; press the “Auto” button into auto mode, the LED on, the unit will also run all steps automatically, and you can press UP/DOWN button to adjust the wait time; press the “Blackout” button, the LED on and the unit into blackout mode.
The main functions are shown below:
16A
5A
VP-240/600
VP-240/600
40 Channels:
30 Channels:
6A
15A
VP-240/600
VP-600:
43 Channels:
14A
VP-240/600
Address Press the MENU button up to when the Address is shown on the display. Pressing ENTER button and 1 will blink. Use DOWN and UP button to change the DMX 512
address (1-512). Once the address has been selected, press ENTER button to setup (or automatically return to the main functions without any change after idling one minute). Back to the previous function without any change, press MENU button.
Channel Mode Press the MENU button up to when the Channel Mode is shown on the display. Pressing ENTER button and 19/43 Ch annel will blink. Use DOWN and UP button to select 19/43 channel or 16/40 Channel …… or 4/10 Channel mode. Once the mode has been selected, press ENTER button to setup. Back to the previous function without any change, please press the MENU button.
Adjust Time
Press the MENU button up to when the Adjust Time is showing on the display. Press ENTER button and Friday will blink. Use DOWN and UP button to select Monday or Tues …… or Sunday. Press the ENTER button to setup ho ur and 14 will blink, use DOWN and UP button to select hour, press the ENTER button to setup minute and 58 will blink, use DOWN and UP button to select minute, press MENU to store and back to the main functions.
Edit Show Press the MENU button up to when the Edit Show is showing on the display. Press
ENTER button and 01 will blink. Use UP/DOWN button to select show (1-30), press ENTER button to setup and use UP/DOWN to edit Time (for example: set the unit on F (from) Monday15:15 T (to) Monday 15:20) and Chase (choose Group 1-3, Num 1-8 and edit F-fade time and W-wait time), Press MENU button to store and back to
the main functions.
Edit Chase (only chase number 6~8 are editable) Press the MENU button up to when the Edit Chase is showing on the display. Press
7A
VP-240/600
ENTER button and 1 will blink, use UP/DOWN button to choose group 1, 2 or 3, press ENTER button to setup and use UP/DOWN to set Num-number (06-08), Leng-length (01-42, the steps, you choose from the total amount of steps, you want to run, for example, if the total amount of steps you set is 42, you can choose only first 1-10 steps to run) and Value (to set step, P-A (output all) or 1-4/10, C-Color, W-White, D-Dimmer), press ENTER button to setup. Back to the previous functi on without any change please press the MENU button.
Manual Test
Press the MENU button up to when the Manual Test is showing on the display. Press ENTER button and 1 will blink, use UP/DOWN button to choose P-A (output all) or 1-4/10, press ENTER button to store, use UP/DOWN to set D-Dimmer, S-Strobe, R-Red, G-Green, B-Blue, W-White, press ENTER button to setup. B ack to the previous function without any change please press the MENU button.
White Balance
Press the MENU button up to when the White Balance is showing on the display. Press ENTER button and 1 will blink, use DOWN/UP button to choose P-output all or 1-4/10, press ENTER button to store, use DOWN/UP to set R-Red, G-Green, B-Blue, press ENTER button to setup. Back to the main functions without any change please press the MENU button.
Auto Test Press the MENU button up to when the Auto Test is showing on the display. Press ENTER button Testing will blink on the display and the unit will run self-test by built-in program. To go back to the previous function please press the MENU button.
LCD Backlight
Press the MENU button up to when the LCD Backlight is sho wing on the display. Press ENTER button to choose Al ways On or Auto Blackout. To go back to the previous function please press the MENU button.
8A
VP-240/600
12 Channels:
4 Channels: 8 Channels:
5 Channels: 4 Channels
13A
VP-240/600
4 Channels:
8. DMX512 Configuration
VP-240:
19 Channels:
VP-240/600
Fixture Use Time
Press the MENU button up to Fixture Use Time, it will show the number of working hours of the unit. To go back to the previous function please press the MENU button.
Software Version
Press the MENU button up to Software Version, It will show the version of software of the unit. To go back to the previous function please pr ess the MENU button.
6. Overview
6.1 Front View
16 Channels
12A
1. DMX On DMX Input
LED
5. Menu
6. Up
7. Enter
8. Down
9. Display
9A
2. MASTER On Master Mode
3. SLAVE On Slave Mode
4. POWER On Power on Press the button to select the programming functions. Press the button to go forward for the desired functions. Press the button to confirm the selected functions. Press the button to go backward for the desired functions. To show the various menu and selected function
VP-240/600
10.Chase Group 1
11.Chase Group 2
12.Chase Group 3
13.Manual
14.Fade
15.Auto
16.Blackout
6.2 Rear View
VP-240:
Press the button to run chase group 1, the LED will be on. Press the button to run chase group 2, the LED will be on. Press the button to run chase group 3, the LED will be on. Press the button into manual mode, the LED will be on. Press the button into fade mode, the LED will be on. Press the button into auto mode, the LED will be on. Press the button to blackout the unit, the LED will be on.
VP-240/600
7. DMX Controller
Using universal DMX controller to control the units, you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal. Press the MENU button up to when the Address is showing on the display. Pressing ENTER button and the display will blink. Use DOWN and UP button to change the DMX512 address. Once the address has been selected, press ENTER button to setup (or automatically return to the main functions without any change after idling one minute). Back to the previous function without any change, press MENU button. Please refer to the following diagram to address your DMX512 chan nel for the first 4 units.
43 Channels:
VP-600:
1. FUSE
2. POWER
3. DMX OUT
4. DMX IN
5. LED
10A
For protecting the unit when the transient current is too big. Power cable for AC input. DMX Output RJ45 or 3 pin XLR socket DMX Input RJ45 or 3 pin XLR socket DC power & signal output for linking LED fixtures.
40 Channels:
30 Channels:
20 Channels:
19 Channels:
16 Channels:
12 Channels:
11 Channels:
10 Channels:
8 Channels:
5 Channels:
11A
Loading...