VISHAY BYG20 User Manual

g
查询BYG20供应商
Fast Silicon Mesa SMD Rectifier
Features
Glass passivated junction
Low reverse current
Soft recovery characteristics
Fast reverse recovery time
Good switching characteristics
Wave and reflow solderable
Applications
Surface mounting Fast rectifier Freewheeling diodes in SMPS and converters Snubber diodes
BYG20
Vishay Telefunken
15 811
Absolute Maximum Ratings
Tj = 25_C
Parameter Test Conditions Type Symbol Value Unit
Reverse voltage BYG20D VR=V =Repetitive peak reverse voltage
Peak forward surge current tp=10ms,
half sinewave Average forward current I Junction and storage
temperature range Pulse energy in avalanche mode,
non repetitive (inductive load switch off)
I
=1A, Tj=25°C E
(BR)R
BYG20G VR=V
BYG20J VR=V
I
FSM
FAV
Tj=T
RRM RRM RRM
stg
R
200 V 400 V 600 V
30 A
1.5 A
–55...+150
20 mJ
Maximum Thermal Resistance
Tj = 25_C
Parameter Test Conditions Symbol Value Unit Junction lead TL=const. R Junction ambient mounted on epoxy–glass hard tissue R
mounted on epoxy–glass hard tissue, 50mm2 35mm Cu R mounted on Al–oxid–ceramic (Al2O3), 50mm2 35mm Cu R
thJL thJA thJA thJA
25 K/W 150 K/W 125 K/W 100 K/W
°
C
Document Number 86009 Rev. 3, 24-Jun-98
www.vishay.de FaxBack +1-408-970-5600
1 (5)
BYG20
g
Vishay Telefunken
Electrical Characteristics
Tj = 25_C
Parameter Test Conditions Type Symbol Min Typ Max Unit
Forward voltage IF=1A V
IF=1.5A V
Reverse current VR=V
VR=V
RRM
, Tj=100°C I
RRM
Reverse recovery time IF=0.5A, IR=1A, iR=0.25A t
Characteristics (Tj = 25_C unless otherwise specified)
F F
I
R R
rr
1.3 V
1.4 V 1
m
10
m
75 ns
A A
100
10
m
1
0.1
R
I – Reverse Current ( A )
VR=V
RRM
200
94 9341
0.01 0 40 80 120 160
Tj – Junction Temperature ( °C )
Figure 1. Typ. Reverse Current vs. Junction Temperature
2.0
1.6
1.2
100K/W
0.8
0.4
FAV
I – Average Forward Current ( A )
0
0
150K/W
40 80 120 160
T
– Ambient Temperature ( °C )94 9340
amb
125K/W
R
thJA
=25K/W
200
100
10
Tj=125°C
1
Tj=75°C
F
0.1
I – Forward Current ( A )
0.01 01 2 3
Tj=25°C
4
VF – Forward Voltage ( V )94 9342
Figure 3. Max. Forward Current vs. Forward Voltage
600
IR=0.5A, iR=0.125A
500
400
T
=125°C
amb
100°C
75°C
50°C
25°C
1.0
rr
t – Reverse Recovery Time ( ns )
94 9343
300
200
100
0
0 0.2 0.4 0.6 0.8
IF – Forward Current ( A )
Figure 2. Max. Average Forward Current vs.
Ambient Temperature
www.vishay.de FaxBack +1-408-970-5600 2 (5)
Figure 4. Max. Reverse Recovery Time vs.
Forward Current
Document Number 86009
Rev. 3, 24-Jun-98