V40 SERIES
UNDERBENCH INSTALLATION INSTRUCTIONS
1. Cabinet dimensions:
Height 820mm – 860mm (40mm adjustable feet)
Width 595mm
Depth 571mm
2. This cabinet is not designed to be fully integrated behind a joinery door.
3. Please note that a minimum cut out of 615mm is required to facilitate
installation,removal and servicing.
4. This cabinet requires 10mm clearance on both sides and top,40mm clearance at
the rear.Where possible a ventilation grid should be installed in the 40mm
clearance at the rear(either in the sides,top or back of the joinery).Minimum grid
size is 200mm x 40mm.
5. This cabinet is front venting.The cabinet draws air from the rear and expels
through the grille under the door at the front.If a kick board is to be placed in
front of the ventilation grill at the front a grill must be fitted in to the kick board
with a minimum air flow allowance of 150cm2.
6. This cabinet has a power switch located on the control panel so power point
location is not critical.
7. This cabinet requires a standard 240 volt/10 amp power point.
8. The power cord is 1.9m in length and is fixed on the right side at the back when
looking from front of cabinet.
9. As with most appliances of today,this cabinet has sensitive electronic
components which are susceptible to damage through lightning and electricity
supply faults.It is therefore advised to use a power surge protector to avoid
problems of this nature
10. Please see below detailed dimensional diagrams.Please note: The diagram below
is for the 85mm plinth recess version.