The information in this document is subject to modification without any prior notice.
VINTEC offers no guarantee for our Beverage Center if it is being used for any purpose
other than that for which it was specifically designed. VINTEC cannot be held
responsible for any error in this manual. VINTEC is not responsible or liable for any
spoilage or damage to beverage or any other contents incidental or consequential to
possible defects of the Beverage Center. Warranty applies to the Beverage Center only and
not to the content of the Beverage Center.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
R600A WARNINGS
The following models use small quantity of R600A (iso-butane) flammable refrigerant in
their sealed system as follow:
AL-V40BVC – 35grams
For your safety observe the following recommenendations.
• This appliance contains a small quantity of R600A refrigerant which is
environmentally friendly, but flammable. It does not damage the ozone layer, nor
does it increase the greenhouse effect.
• During transportation and installation, ensure that the tubing of the refrigerant
circuit is not damaged.
• Avoid using or manipulating sharp objects nearby the appliances.
• Leaking refrigerant can ignite and may damage the eyes.
• In the event any damage does occur, avoid exposure to open fires and any device
which creates a spark. Disconnect the appliance from the mains power.
• Thoroughly ventilate the room in which the appliance is located for several
minutes.
• Notify Customer Service for necessary action and advice.
• The room for installing the appliance must be at least 1 cubic metre per 8 grams of
refrigerant. The refrigerant quantity contained in this appliance is listed above in
grams; it is also noted on the Rating Plate of the appliance.
1
It is hazardous for anyone other than an Authorised Service Person to carry out
servicing or repairs to this appliance. In Queensland the authorized person must
hold a Gas Work Authorisation for hydrocarbon refrigerants, before carrying out
servicing or repairs which involve the removal of covers.
– WARNING: Keep ventilation openings, in the appliance enclosure or in the built-in
structure, clear of obstruction.
– WARNING: Do not use mechanical devices or other means to accelerate the defrosting
process, other than those recommended by the manufacturer.
– WARNING: Do not damage the refrigerant circuit.
– WARNING: Do not use electrical appliances inside the food storage compartments of
the appliance, unless they are of the type recommended by the manufacturer.
The environment and personal safety must be considered when disposing of this appliance.
Please ensure the appliance is taken to a recycle center for safe recycling. DO NOT
dispose of the appliance in land fill as the insulation and refrigerant gas contained in these
appliances are flammable.
Allow 24 hours before switching on the Beverage Center. During this time we
recommend that you leave the door open to clear any residual odors.
BEFORE LOADING & PLUGGING IN THE BEVERAGE CENTER
Important: All models without front venting (air opening) are strictly for free standing
only. ( see technical chart)
Recommendations:
The location you have selected for your Beverage Center should:
- be unencumbered and well ventilated;
- be well away from any heat source and direct sunlight;
- not be too damp (laundry, pantry, bathroom etc.);
- have a flat floor,
- have a standard and reliable electricity supply (standard socket to country standards,
linked to the ground), it is NOT recommended to use a multi-socket or extension lead.
- have a surge protector fitted to the electrical outlet
- away from the microwave.
Certain microwave ovens do not have wave interference shield. When placed within a 1
meter vicinity of the Beverage cabinet, they may affect the operation of the Beverage
cabinet.
2
The Beverage Center should be placed where the ambient temperature is between 5ºC to
35ºC. If the ambient temperature is above or below this range, the performance of the unit
may be affected. Placing your unit in extreme cold or hot conditions may cause interior
temperatures to fluctuate. The ideal range of temperature may not be reached. (See
Climate Class at the end of this manual)
Grounding instructions
The Beverage Center must be grounded in case of an electrical short circuit. Grounding
reduces the risk of electrical shock. The Beverage Center is equipped with a power cord
having a grounding wire and plug. The Beverage Center plug must be plugged into a
properly affixed and grounded electrical outlet.
Note: In locations where there is frequent lightning, it is advisable to use surge
protectors.
Improper use of the grounding plug can result in the risk of electric shock. Consult a
qualified electrician or service person if the grounding instructions are not completely
understood.
If the supply cord is damaged, it must be replace by a qualified person in order to avoid electrical hazard.
Installing your Beverage Center
Unpack and remove all of the protection and adhesive strips from the packaging around
and inside the Beverage Center.
The Beverage Center must be positioned such that the plug is accessible. Release the
power cord. Move your Beverage Center to its final location. The Beverage Center should
be installed in a suitable place where the compressor will not be subject to physical
contact.
Leveling your Beverage Center: Beverage Center must be leveled BEFORE loading
your Beverage.
Your Vintec Beverage Center is equipped with 4 adjustable feet to facilitate easy leveling.
VINTEC recommends that you tighten the back feet to the maximum and adjust the front
feet to create a level.
Back spacer:
Compressor run appliances require proper ventilation for proper and longer usage. Your
Vintec Beverage Center is supplied with a back spacer. Affixed the back spacer at the
back of air circulation and heat evacuation.
3
IMPORTANT - THIS SPACER MUST BE ATTACHED TO THE UNIT BEFORE
INSTALLATION FOR VENTILATION PURPOSE. FAILURE TO DO SO VOIDS THE
WARRANTY
TURNING ON YOUR BEVERAGE CENTER
Plug in and switch on the unit by pressing on the power button for a few seconds.
When you use the Beverage Center for the first time (or restart the Beverage Center after
having it shut off for a long time), there will be a few degrees, variance between the
temperature you have selected and the one indicated on the LED readout. This is normal
and it is due to the length of the activation time. Once the Beverage Center is running for a
few hours everything will stabilize.
Important: If the unit is unplugged, power is lost, or turned off, wait 5 minutes before
restarting the unit. The Beverage Center will not start if you attempt to restart before
this time delay.