![](/html/dc/dc6e/dc6e3b99c4ebedaff9e68f3a98dbc15f54f3671e723e36d397ae9b404763cd9b/bg3.png)
Important information that may impact
!
your Manufacturer’s Warranty
Adherence to the directions for use in this manual is extremely important for health
and safety. Failure to strictly adhere to the requirements in this manual may result
in personal injury, property damage and affect your ability to make a claim under the
Vintec manufacturer’s warranty provided with your product. Products must be used,
installed and operated in accordance with this manual. You may not be able to claim
on the Vintec manufacturer’s warranty in the event that your product fault is due to
failure to adhere this manual.
User Manual
V40BVCBK V40BVCS3 3
![](/html/dc/dc6e/dc6e3b99c4ebedaff9e68f3a98dbc15f54f3671e723e36d397ae9b404763cd9b/bg4.png)
The information in this document is subject to modification without
any prior notice.
Somes models are available in dedicated countries only.
VINTEC offers no guarantee for our Beverage Center if it is being used for any purpose
other than that for which it was specifically designed. VINTEC cannot be held
responsible for any error in this manual. VINTEC is not responsible or liable for any
spoilage or damage to beverage or any other contents incidental or consequential to
possible defects of the Bev
erag
e Center. Warranty applies to the Beverage Center only and
not to the content of the Beverage Center.
This appliance is not intended for use by persons (including children) with reduc ed
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
R600A WARNINGS
The following
els use small quantity of R600A (iso-butane) flammable refrigerant:
mod
V40BVC – 35g S3/BK
For your safety please observe the following recommendations :
environmentally friendly, but flammable. It does not da mage the ozone layer, nor
does it increase the greenhouse effect.
circuit is not damaged.
•
that creates a spark. Disconnect the appliance from the mains power.
•
minutes.
User Manual
V40BVCBK V40BVCS34
![](/html/dc/dc6e/dc6e3b99c4ebedaff9e68f3a98dbc15f54f3671e723e36d397ae9b404763cd9b/bg5.png)
refrigerant. The refrigerant quantity contained in this a ppliance is listed above in
grams; it is also noted on the Rating Plate of the appliance.
It is hazardous for anyone other than an Authorised Service Person to carry out
servicing or repairs to this appliance.
– WARNING: Keep ventilation openings in the appliance enclosure or in the built-in
structure clear of obstruction.
– W ARNING: Do not use mechanical devices or other means to accelerate the defrosting
process, other than those recom
mended by the manufacturer.
– WARNING: Do not damage the refrigerant circuit.
– WARNING: Do not use electrical appliances inside compartments of the appliance.
– WARNING: In Queensland Australia the authorized person must hold a Gas Work
Authorisation for hydrocarbon refrigerants, before carrying out servicing or repairs which
involve the removal of covers.
The environment and personal safety must be considered when disposing of this appliance.
Please ensure the appliance is taken to a recyc
le center for safe recycling. DO NOT
dispose of the appliance in land fill as the insulation and refrigerant gas contained in these
appliances are flammable.
Allow 24 hours before switching on the Beverage Center. During this time we
recommend that you leave the door open to clear any residual odors.
BEFORE LOADING & PLUGGING IN THE BEVERAGE CENTER
Important: All models without front venting (air opening) are strictly for free standing
only. ( see technical chart)
Recommendations:
The locat
ion you have selected for your Beverage Center should:
- be unencumbered and well ventilated;
- be well away from any heat source and direct sunlight;
- not be too damp (laundry, pantry, bathroom etc.);
- have a flat floor;
- have a standard and reliable electricity supply (standard socket to country standards,
linked to the ground), it is NOT recommended to use a multi-socket or extension lead.
- have a surge protector fitted to the electrical outlet;
- away from the microwave oven. Certain micro
wave ovens do not have wave interference
shield. When placed within 1 meter vicinity of the Beverage Center, they may affect the
operation of the Beverage Center.
User Manual
V40BVCBK V40BVCS3 5
![](/html/dc/dc6e/dc6e3b99c4ebedaff9e68f3a98dbc15f54f3671e723e36d397ae9b404763cd9b/bg6.png)
The Beverage Center should be placed where the ambient temperature is between 5ºC to
35ºC. If the ambient temperature is above or below this range, the performance of the unit
may be affected. Placing your unit in extreme cold or hot conditions may cause interior
temperatures to fluctuate. The ideal range of temperature may not be reached. (See
Climate Class at the end of this manual)
Grounding instructions
The Beverage Center must be grounded in case of an electrical short circuit. Grounding
re
duces the risk of electrical shock. The Beverage Center is equipped with a power cord
ving a grounding wire and plug. The Beverage Center plug must be plugged into a
ha
properly affixed and grounded electrical outlet.
Note: In locations where there is frequent lightning, surge protectors MUST be used.
Improper use of the grounding plug can result in the risk of electric shock. Consult a
qualified electrician or service person if the grounding instructions are not completely
understood.
If the supply cord i
s damaged, it must be replace by a qualified person in order to avoid
electrical hazard.
nstalling your Beverage Center
I
Unpack and remove all of the protection and adhesive strips from the packaging around
and inside the Beverage Center.
The Beverage Center must be positioned such that the plug is accessible. Release the
power cord. Move your Beverage Center to its final location. The Beverage Center should
be installed in a suitable place where the compressor will not be subject to physical contac
This center cannot be integrated behind a solid door – doing so voids the warranty.
t.
Level
ing your Beverage Center: Beverage Center must be leveled BEFORE
loading
your beverages.
Your Vintec Beverage Center is equipped with 4 adjustable feet to facilitate easy leveling.
VINTEC recommends that you screw the back feet toward the base s o they are in the
shortest position and adjust the front feet to level the Beverage Center.
Back spacer:
Compressor run appliances require proper ventilation for proper and longer usage. Your
Vintec Bever age Center is supplied with a back spacer. Affixed the back spacer at the
back of air circulation and heat evacuation.
User Manual
V40BVCBK V40BVCS36