V20 SERIES
V20SGES3
UNDERBENCH INSTALLATION INSTRUCTIONS
These units are not designed for outdoor use – please see conditions at the end of this
information.
1. Cabinet dimensions:
Height 820mm (40mm adjustable feet) Width 295mm
Depth (without handle) 575mm + 30mm spacer = 605mm
Depth (with handle) 575mm + 43mm handle + 30mm spacer = 648mm
2. This cabinet is not designed to be fully integrated behind a joinery door.
✓
3. Please note that a minimum cut out of 300mm x 825mm is required to facilitate installation, removal, ventilation and servicing.
✕
Minimum Cutout Diagram

4. This cabinet requires 2.5mm clearance on both sides, 5mm at the top and 30mm
clearance at the rear. A ventilation grid MUST be installed in the 30mm clearance at the
rear. Because hot air rises it is imperative that a grille with a Minimum grid size of 200mm
x 40mm is installed at the top of the back wall or on either side at the rear at the top
giving cool fresh air full access to ow into the 30mm gap at the rear of the cabinet. This
means that you must not install the grille close to other appliances such as an oven or to
an area that is sealed or with out access to fresh cool air. (You MUST call the Vintec Service Department on 1800 771 776 if you do not understand any part of this statement.
Failing to comply with the above specications could result in WARRANTY void.)
Suitable points for ventilation grille.
Note: Only one vent is required.
Benchtop
Correct power point location
200
40
5. This cabinet is front venting. The cabinet draws air from the rear and expels through
the grille under the door at the front. If a kick board is to be placed in front of the venti-
lation grill at the front a grill must be tted in to the kick board with a minimum air ow
allowance of 150cm2.
5mm

6. This cabinet has a power switch located on the control panel so powerpoint location is
not critical.
7. This cabinet requires a standard 240 volt/10 amp power point.
8. The power cord is 1.9m in length and is xed on the right side at the back when looking from front of cabinet.
9. As with most appliances of today, this cabinet has sensitive electronic components
which are susceptible to damage through lightning and electricity supply faults. It is
therefore advised to use a power surge protector to avoid problems of this nature and to
avoid piggybacking with other appliances.
Further Instructions:
The location you have selected for your wine cellar should:
- be unencumbered and well ventilated;
- be well away from any heat source and direct sunlight;
- not be too damp (laundry, pantry, bathroom etc.);
- have a at oor,
- have a standard and reliable electricity supply (standard socket to country standards,
linked to the ground), it is NOT recommended to use a multi-socket or extension lead.
- have a surge protector tted to the electrical outlet away from the microwave.
Certain microwave ovens do not have wave interference shield. When placed within a 1
meter vicinity of the wine cabinet, they may aect the operation of the wine cabinet.

OUT DOOR USE
Please note that, whilst Vintec units are not designed for outdoor use they can be placed
in certain Al Fresco areas but they MUST be well undercover – NEVER exposed to sunlight or the elements.
These units have glass doors & must not be situated where they are exposed to sunlight
or reected sunlight. In areas of high humidity there will be condensation on the glass
doors. The units must be under signicant cover & removed from any heat source (BBQ
etc)
The ventilation requirement indicated for indoor use must be increased when situated
outdoors by at least 2 cm on both sides & 3cm on top, 3 cm at the back with a large
vent at the top of the back wall to facilitate heat evacuation. Because hot air rises it is
imperative that a grille with a Minimum grid size of 200mm x 40mm is installed at the top
of the back wall or on either side at the rear at the top giving cool fresh air full access to
ow into the 30mm gap at the rear.
✕
✓
✕
✕
✓

ONE OR MORE UNITS
The V20 Range can be installed next to each other in a row. All installation instructions
should be followed.
The V20 range is equipped with a handle on the front of the unit. When installing a row of
V20 units allow a minimum gap of 5mm between each unit and 2.5mm on the sides.
600.0
2.5 2.55.0
5.0
900.0
2.5
5.0
2.55.0 5.0
Notes:
- V20 model are built-in type as per the drawings thereafter;
The wine cellar should be placed where the ambient temperature is between 5oC to
35oC. If the ambient temperature is above or below this range, the performance of the
unit may be aected. Placing your unit in extreme cold or hot conditions may cause interior temperatures to uctuate. The ideal range of temperature may not be reached.
Not complying with any of the above instructions may result in WARRANTY void.

Suitable points for ventilation grille.
Note: Only one vent is required.
Vent Specications
Benchtop
Correct power point location
5mm

43.0
605.0
575.0
2.5
30.0
5.05.0
605.0
300.0
575.0
30.0
825.0
820.0
295.0
Front Elevation Top ViewSide View
2.5 2.5
V20 Installation Dimensions