Vintec V20BVCBK User Manual

Page 1
Armoire à vin
BeveragePreservationTechnology
USERMANUAL
V40BVCAL/S3/BK
V20BVCS3/BK
V20BVC V26BVC
code:
VIM201604/BVC/01
Page 2
WARNING
This
appliance
contains
a
small
quantity
of
R600A
refrigerant
which
is
During
transportation
and
installation,
ensure
that
the
tubing
of
the
refrigerant
Avoid
using
or
manipulating
sharp
objects
near
by
the
appliances.
Leaking
refrigerant
can
ignite
and
may
damage
the
eyes.
•Inthe
event
any
damage
does
occur,
avoid
exposure
to
open
fires
and
any
device
Thoroughly
ventilate
the
room
in
which
the
appliance
is
located
for
several
Notify
Customer
Service
for
necessary
action
and
advice.
Theinformationinthisdocumentissubjecttomodificationwithout
anypriornotice.
Somesmodelsareavailableindedicatedcountriesonly.
. VINTEC offersnoguaranteeforourBeverageCenterifitisbeingusedforanypurpose otherthanthatforwhichitwasspecificallydesigned. VINTEC cannotbeheld responsibleforanyerrorinthismanual. VINTEC isnotresponsibleorliableforany spoilageordamagetobeverageoranyothercontentsincidentalorconsequentialto possibledefectsoftheBeverageCenter.WarrantyappliestotheBeverageCenteronlyand nottothecontentoftheBeverageCenter.
Thisapplianceisnotintendedforusebypersons(includingchildren)withreduced physical,sensoryormentalcapabilities,orlackofexperienceandknowledge,unlessthey havebeengivensupervisionorinstructionconcerninguseoftheappliancebyaperson responsiblefortheirsafety.
Childrenshouldbesupervisedtoensurethattheydonotplaywiththeappliance.
R600AWARNINGS
ThefollowingmodelsusesmallquantityofR600A(iso-butane)flammablerefrigerant:
V40BVC – 35g AL/S3/BK V26BVC – 30g V20BVC – 25g S3/BK
Foryoursafetypleaseobservethefollowingrecommendations:
environmentallyfriendly,butflammable.Itdoesnotdamagetheozonelayer,nor doesitincreasethegreenhouseeffect.
circuitisnotdamaged.
thatcreatesaspark.Disconnecttheappliancefromthemainspower.
minutes.
1
code:
VIM201604/BVC/01
Page 3
The
room
for
installing
the
appliance
must
beatleast
1
cubic
metre
per8grams
of
refrigerant.Therefrigerantquantitycontainedinthisapplianceislistedabovein grams;itisalsonotedontheRatingPlateoftheappliance.
ItishazardousforanyoneotherthananAuthorisedServicePersontocarryout servicingorrepairstothisappliance.
– WARNING:Keepventilationopeningsintheapplianceenclosureorinthebuilt-in structureclearofobstruction. – WARNING:Donotusemechanicaldevicesorothermeanstoacceleratethedefrosting process,otherthanthoserecommendedbythemanufacturer.
WARNING:Donotdamagetherefrigerantcircuit.WARNING:Donotuseelectricalappliancesinsidecompartmentsoftheappliance.
WARNING:InQueenslandAustraliatheauthorizedpersonmustholdaGasWork
Authorisationforhydrocarbonrefrigerants,beforecarryingoutservicingorrepairswhich involvetheremovalofcovers.
Theenvironmentandpersonalsafetymustbeconsideredwhendisposingofthisappliance. Pleaseensuretheapplianceistakentoarecyclecenterforsaferecycling. DONOT disposeoftheapplianceinlandfillastheinsulationandrefrigerantgascontainedinthese appliancesareflammable.
Allow24hoursbeforeswitchingontheBeverageCenter.Duringthistimewe recommendthatyouleavethedooropentoclearanyresidualodors.
BEFORELOADING&PLUGGINGINTHEBEVERAGECENTER
Important:Allmodelswithoutfrontventing(airopening)arestrictlyforfreestanding only.(seetechnicalchart)
Recommendations:
ThelocationyouhaveselectedforyourBeverageCentershould:
-beunencumberedandwellventilated;
-bewellawayfromanyheatsourceanddirectsunlight;
-notbetoodamp(laundry,pantry,bathroometc.);
-haveaflatfloor;
-haveastandardandreliableelectricitysupply(standardsockettocountrystandards, linkedtotheground),itisNOTrecommendedtouseamulti-socketorextensionlead.
-haveasurgeprotectorfittedtotheelectricaloutlet;
-awayfromthemicrowaveoven.Certainmicrowaveovensdonothavewaveinterference
shield.Whenplacedwithin1metervicinityoftheBeverageCenter,theymayaffectthe
operationoftheBeverageCenter.
2
code:
VIM201604/BVC/01
Page 4
TheBeverageCentershouldbeplacedwheretheambienttemperatureisbetween5ºCto 35ºC.Iftheambienttemperatureisaboveorbelowthisrange,theperformanceoftheunit maybeaffected.Placingyourunitinextremecoldorhotconditionsmaycauseinterior temperaturestofluctuate. Theidealrangeoftemperaturemaynotbereached.(See ClimateClassattheendofthismanual)
Groundinginstructions
TheBeverageCentermustbegroundedincaseofanelectricalshortcircuit.Grounding reducestheriskofelectricalshock.TheBeverageCenterisequippedwithapowercord havingagroundingwireandplug.TheBeverageCenterplugmustbepluggedintoa properlyaffixedandgroundedelectricaloutlet.
Note: Inlocationswherethereisfrequentlightning,surgeprotectorsMUSTbeused.
Improperuseofthegroundingplugcanresultintheriskofelectricshock.Consulta qualifiedelectricianorservicepersonifthegroundinginstructionsarenotcompletely understood.
Ifthesupplycordisdamaged,itmustbereplacebyaqualifiedpersoninordertoavoid electricalhazard.
InstallingyourBeverageCenter
Unpackandremovealloftheprotectionandadhesivestripsfromthepackagingaround andinsidetheBeverageCenter. TheBeverageCentermustbepositionedsuchthattheplugisaccessible.Releasethe powercord.MoveyourBeverageCentertoitsfinallocation.TheBeverageCentershould beinstalledinasuitableplacewherethecompressorwillnotbesubjecttophysicalcontact. Thiscentercannotbeintegratedbehindasoliddoor – doingsovoidsthewarranty.
LevelingyourBeverageCenter: BeverageCentermustbeleveledBEFORE loading yourbeverages. YourVintecBeverageCenterisequippedwith4adjustablefeettofacilitateeasyleveling. VINTEC recommendsthatyouscrewthebackfeettowardthebasesotheyareinthe shortestpositionandadjustthefrontfeettoleveltheBeverageCenter.
Backspacer:
Compressorrunappliancesrequireproperventilationforproperandlongerusage.Your VintecBeverageCenterissuppliedwithabackspacer.Affixedthebackspaceratthe backofaircirculationandheatevacuation.
3
code:
VIM201604/BVC/01
Page 5
IMPORTANT-THISSPACERMUSTBEATTACHEDTOTHEUNITBEFORE
INSTALLATIONFORVENTILATIONPURPOSE.FAILURETODOSOVOIDSTHE
WARRANTY
TURNINGONYOURBEVERAGECENTER
Pluginandswitchontheunitbypressingonthepowerbutton forafewseconds. WhenyouusetheBeverageCenterforthefirsttime(orrestarttheBeverageCenterafter havingitshutoffforalongtime),therewillbeafewdegrees,variancebetweenthe temperatureyouhaveselectedandtheoneindicatedontheLEDreadout.Thisisnormal anditisduetothelengthoftheactivationtime.OncetheBeverageCenterisrunningfora fewhourseverythingwillstabilize.
Important:Iftheunitisunplugged,powerislost,orturnedoff,wait5minutesbefore restartingtheunit.TheBeverageCenterwillnotstartifyouattempttorestartbefore thistimedelay.
4
code:
VIM201604/BVC/01
Page 6
OperatingNoises
Toreachthedesiredtemperaturesettings, VINTEC BeverageCenter,likeallBeverage Centersoperatingwithcompressorsandfans,mayproducethefollowingtypesofnoises. Thesenoisesarenormalandmayoccurasfollows:
-Gurglingsound-causedbytherefrigerantflowingthroughtheappliancescoils.
-Cracking/poppingsounds-resultingfromthecontractionandexpansionofthe refrigerantgastoproducecold.
-Fanoperatingsound-tocirculatetheairwithintheBeverageCenter.
Anindividualsperceptionofnoiseisdirectlylinkedtotheenvironmentinwhichthe BeverageCenterislocated,aswellthespecifictypeofmodels. VINTEC Beverage Centersareinlinewithinternationalstandardsforsuchappliances. VINTEC willalways doitsutmosttosatisfyitscustomersbutwillnotretakepossessionofthegoodsdueto complaintsbasedonnormaloperatingnoiseoccurrences.
LOADINGYOURBEVERAGECENTER
Youmayloadyourbeveragebottlesinsingleordoublerowswhiletakingnoteofthe following:ifyoudonothaveenoughbottlestofillyourBeverageCenter,itisbetterto distributetheloadthroughouttheBeverageCentersoastoavoid allontopor all belowtypeloads.
-Doremoveorrelocateadjustableshelvestoaccommodatelargertypeofbottlesor increasethecapacityofthecellarbystackingthebottlesupwhennecessary.(See removingshelves)
-Keepsmallgapsbetweenthewallsandthebottlestoallowaircirculation.Asinan
undergroundcellar,aircirculationisimportanttopreventmouldandforabetter homogeneoustemperaturewithinthecellar.
-DonotoverloadyourBeverageCentertofacilitateaircirculation.
-Avoidobstructingtheinternalfans(locatedinsideonthebackpaneloftheBeverage Center).
-Donotslidetheshelvesoutwardsbeyondthefixedpositioninordertopreventthe bottlesfromfalling.
-DonotpulloutmorethanoneloadedshelfatatimeasthismaycausetheBeverage Centertotiltforward.
-Donotcovertheshelveswithalloyfoilorothermaterials,asitwillobstructair circulation.
-DonotmoveyourBeverageCenterwhileitisloadedwithbeverages.Thismightdistort thebodyoftheBeverageCenterandcausebackinjury.
5
code:
VIM201604/BVC/01
Page 7
TYPESOFREGULATION
The
controls
of
your
center
Pleasenotethat,dependingontheloadingandsettingschosen,ittakesabout24hoursfor theBeverageCentertoseethetemperaturestabilizing.
DuringthistimeLEDseemstomoveerratically.Itisnormalandthisprocessoccurs wheneverthesettingismodifiedand/orwheneveralargeamountofbottlesareaddedto theunit.
TEMPERATURESETTINGS
Important:TheLCDdisplays,bydefault,theactualinternalairtemperature.
Thetemperaturesettingsarepre-setatthefactorysettingof5ºC.Intheeventofapower interruption,allprevioustemperaturesettingsareautomaticallyerasedanditwillrevertto thepresettemperaturesettings.
Itisimportanttounderstandthatthereisadifferencebetweentheairtemperatureinside the BeverageCenter andtheactualtemperatureofthe Beverage: Youwillneedtowait
approximately12hoursbeforenoticingtheeffectsoftemperatureadjustmentduetothe criticalmasswithinafullBeverageCenter. Oncethetemperatureisset,itisstronglyadvisednottotoywithitoradjustfrequently. ThethermostatwillmaintainthetemperatureinsidetheBeverageCenterwithina+/-
2.5ºCrange.Butthethermalinertiaofthebeveragesandtheglassissuchthat,withinthis
temperaturerange,theactualtemperatureoftheBeveragewillonlyfluctuate0.5ºCto1ºC.
AdjustthedesiredcoolingtemperaturebypressingtheUPorDOWNbuttons.Each depressionofthebuttonwillscrollthroughtheavailabletemperaturesettingsin incrementsof1degreeCelsius.Thetemperaturesettingcanbeadjustedfrom2℃to10
Tovisualizethe settemperature,pressandholdtheUPorDOWNbuttons,the set temperaturewilltemporarily flashintheLEDdisplayfor5seconds.
6
code:
VIM201604/BVC/01
Page 8
Internallight
Inordertoreduceenergyconsumption,thiswinecabinetwillautomaticallyswitchoffthe LEDlightsafter10minutes. IfyouwanttheLEDlighttoremainoncontinuously,thisispossible.Pleasepressand holdthe"LIGHT"buttonfor5seconds,thedisplaywillshow"LP".After4secondsthe displaywillrevertbacktonormalandthelightwillremainonuntilmanuallyswitchedoff. Ifyouwanttorevertbackandconserveenergy(recommended),pleasepressandholdthe "LIGHT"buttonfor5second,thedisplaywillshow"LF",after4secondsthedisplaywill revertbacktonormal,andthelightwillautomaticallyswitchoffafter10minutes.
DEFROSTING/CONDENSATION/HYGROMETRY/VENTILATION
Yourbeveragecenterisdesignedwith Auto-cycledefrostsystem.During Off-cycle therefrigeratedsurfacesofthebeveragecenterdefrostautomatically.Defrostwaterfrom thebeveragecenterstoragecompartmentdrainsautomaticallyandpartofitgoesintoa drainagecontainer,whichislocatedatthebackofthebeveragecenternexttothe compressor.Theheatistransferredfromthecompressorandevaporatesanycondensation thathascollectedinthepan.Partoftheremainingwateriscollectedwithinthebeverage centerforhumiditypurposes. Thissystemenablesthecreationofthecorrecthumiditylevelinsideyourbeveragecenter requiredbythenaturalcorktomaintainalonglastingseal.
Notes: Thewatercollectedbycondensation,isthereforerecycled.Underextremelydry environmentalconditions,youmayhavetoaddsomewaterintothewatercontainer providedwithyourbeveragecenter.
Allunitsareequippedwithadoubleglazedglassdoorthathasathirdinternalacrylic layertominimizecondensationontheglassdoor.
Thebeveragecenterisnottotallysealed;freshairadmissionispermittedthroughthe drainpipe.Airiscirculatedthroughtheunitbymeansofafan/fansandtheslattedshelves.
Notes: Duringtherefrigeratingcycle,heatisgivenoffanddispersesthroughtheexternal surfacesofthebeveragecenter.Avoidtouchingthesurfacesduringthosecycles.
ADJUSTABLESHELVES
Adjusting/removingtheshelves
Whenremovinganyoftheseshelvesoutoftherailcompartment-tofitorremovethe shelf-tilttheshelfasperthediagramandsimplypullout,orpushintheshelfuntilitsits onthesupportbracketssecurely.
7
code:
VIM201604/BVC/01
Page 9
REVERSIBILITYOFTHEDOOR
-
Depending
on
the
type
of
handle
your
wine
cabinet
is
equipped
with,
the
door
may
notbereversible
or
may
require
that
a
leftorright
opening
door
be
ordered
to
change
the
opening
side.
Warning:Toavoidaccidentsduringtheprocessofchangingthedoor,werecommendthat yougetassistance.Theglassdoorisheavyandmaycauseinjuryifdropped.
-Dependingontothemodelandthetypeofhandleyourwinecabinetisequippedwith, youmayhavetorotatethedoorthrough180degrees.
40BVC/AL
1Lowerhinge(Right) 2Lockscrews 3Tophinge(Right) 4LockScrews 5Tophinge(Left) 6Lowerhinge(Left) 7Door
8
code:
VIM201604/BVC/01
Page 10
- Whileholdingthedoorfirmly, removethethreelockscrews(2)fromthelower
1.
Open
the
door
to90degree
angle,
take
out
the2screws
(2)
from
lower
door
axis
(3),
2.Unscrew
the
screw
(11)
located
underneath
the
door
frame
and
the
limit
device
(10),
3.
Take
out
the3hinge
screws
(6)
from
the
top
hinge
(right)
(5)
and
remove
it.
(Fig.
C)
righthingemodule,andremoveit.(Fig.1)
-Removethethreelockscrews(4)fromthetoprighthingeandremovethehinge (3).(Fig.3)
-Fixthetoplefthinge(5)atthetopleftcornerwiththethreelockscrews(4).(Fig.4)
-Whileholdingthedoor, inserttheaxiscoreintothedoors(7)upperlefthinge hole.Fixtheleftbottomhingesbyinsertingtheaxiscorefirstintothedoorslower lefthingehole(6).Thensecurethelowerlefthingetofinishthedoorreplacement. (Fig.5)
V40BVCS3&BK
1.Lowerhinge(Right) 2.Screws 3.Dooraxis
4.Door 5.Tophinge(Right) 6.HingeScrews
7.Tophinge(Left) 8.Decorativenail 9.Lowerhinge(Left)
10.Doorlimitdevice 11.Screw
removethedoor(4),Removetheaxisplate(3)fromthedoor,(Fig.A).
andrelocateitatleftendsideofthedoorframe.(Fig.A/B)
9
code:
VIM201604/BVC/01
Page 11
4.
Remove
decorative
nail
(8)
from
left
topofcabinet
and
install
spare
top
hinge
(Left)
(7)
atlefttopofcabinetwith3screws.(Fig.D)
5.
Following
the
above
procedure,
install
the
spare
lower
hinge
to
the
left
(9).
(Fig.
E)
6.Install
and
aligned
the
door.
Insert
the
plastic
caps
to
cover
the
holes(8).
7.
V26BVC&V20BVC /S3/BK
-Unscrewthelockscrews(1);(Fig.1)toremovethedooraxislocatedatthebottom.
- Whileholdingthedoorfirmly, pullthedoor(5)outwardandtakeitout;(Fig.2)
-Removethe3boltsandtakeouttherighttophinge(2);(Fig.3)
-FixthelefttophingeandthebottomlefthingewiththeboltsasperFig.4,
-Re-installthedoorthesamewayitwasremovedandfixbackthedooraxis.
1Lockscrews 2Lowerhinge(Right) 3Dooraxis 4Tophinge(Right) 5Door 6Cabinetbody 7Tophinge(Left) 8Lowerhinge(Left)
10
code:
VIM201604/BVC/01
Page 12
Ifitislefthinge,reversethedoorasthesameway.
1.
Vintec
beverage
Center
dimensions:
2.
This
Vintec
Beverage
Center
is
not
designed
tobefully
integrated
behind
a
joinery
3.
Please
note
that
:
V40/V26/V20SERIES
UNDER-BENCHINSTALLATIONINSTRUCTIONS
V40
Height820mm – 860mm(40mmadjustablefeet) Width595mm Depth571mm+30mmstopper(Totalof601mm)
V26
Height820mm – 830mm(10mmadjustablefeet) Width380mm Depth572mm+30mmstopper(Totalof602mm)
V20
Height810mm – 830mm(10mmadjustablefeet) Width295 – 300mm Depth561– 592mm+30mmstopper(Totalof622mm)
door.
ForV40aminimumcutoutwidthof615mmisrequiredtofacilitateinstallation, removalandservicing. ForV26aminimumcutoutwidthof400mmisrequiredtofacilitateinstallation, removalandservicing. ForV20aminimumcutoutwidthof320mmisrequiredtofacilitateinstallation, removalandservicing.
4. Toprovidegoodperformancethiscabinetrequiresadequateventilation.TheVintec
BeverageCentercabinetrequires10mmclearanceonbothsides,ontop;and30mm clearanceattherear.(Youmustfitthebackspacerprovided,itwillensurethe minimum30mmclearanceattherear).Aventilationgridneedstobeinstalledin this30mmclearanceareaattherear.Forgoodventilation,itisnecessarytoinstalla grillwithaminimumsizeof200x40mmatthetopofthebackwalloroneitherside atthetoprear – refertodiagramsonthefollowingpages.Thisistoallowcooler freshairtoflowintothe30mmgapattherearofthecabinet.Theventilationgrill mustnotbeinstalledclosetoanovenornexttoasealedareawithoutaccessto freshcoolair.(DocallVintecsServiceDepartmentforfurtherexplanation.Failure tocomplywiththeabovespecificationscouldvoidtheWARRANTY.)
11
code:
VIM201604/BVC/01
Page 13
VENTSPECIFICATIONS
FrontView(V40)
FrontView(V26)
FrontView(V20)
400mm
12
code:
VIM201604/BVC/01
Page 14
FrontView(V20)
V26&V20&AL-V40BVC
etc
.
FrontView(V20)
400mm
320mm
Crosssection
30mm *
ThisappliestoallV40&V20BVC BK&S3models.
*only10mmrequiresfor
13
code:
VIM201604/BVC/01
Page 15
5.
This
Vintec
Beverage
Center
is
front
venting.
The
cabinet
draws
air
from
the
front
andrearandexpelsthroughthegrillunderthedooratthefront.Ifajoinerykick
6.
This
unit
hasapower
switch
located
on
the
control
panel.
Power
point
location
is
7.
This
unit
requires
a
standard
240
volt/10
amp
power
point.
8.
The
power
cord
is
1.9m
in
length
andisaffixed
to
the
right
side
at
the
back
of
the
9.Aswith
most
appliances
of
today,
this
cabinet
has
sensitive
electronic
components
10.
Please
see
detailed
dimensional
diagrams
in
the
preceding
pages.
Please
note:
The
boardisbeingplacedinfrontoftheBeverageCenter,agrillofatleastthesame widthastheBeverageCentergrillandwithaminimumairflowallowanceof 150cm2mustbeinstalledintothekickboard.
thereforenotcritical.
cabinet.
whicharesusceptibletodamagebylightningandelectricitysupplyfaults.Itis thereforeadvisabletouseapowersurgeprotectortoavoidproblemsofthisnature.
precedingdiagramisforthe85mmplinthrecessmodels.
FurtherInstructions: ThelocationyouhaveselectedforyourBeverageCentreshould:
-beunencumberedandwellventilated;
-bewellawayfromanyheatsourceanddirectsunlight;
-notbetoodamp(laundry,pantry,bathroometc.);
-haveaflatfloor;
-haveastandardandreliableelectricitysupply(standardsockettocountrystandards,
linkedtotheground).ItisNOTrecommendedtouseamulti-socketorextensionlead;
-haveasurgeprotectorfittedtotheelectricaloutlet;
-beawayfromthemicrowave; Note:Certainmicrowaveovensdonothavewaveinterferenceshield.Whenplacedwithin a1metervicinityoftheBeverageCenter,theymayaffecttheoperationofthewine cabinet.
-donotcovertheglassdoorwithanyotherkindofdoor -thisunitCANNOTbe integratedbehindjoinery
Notes: NotcomplyingwithanyoftheaboveinstructionsmayresultinWARRANTYvoid.
14
code:
VIM201604/BVC/01
Page 16
Dimensionaldrawings: V40BVCS3/BK
30
10
Front View Top View
AL-V40BVC
615 595
10
555
30
850
820
30
525
31
30
555
10
10
525
Side View
10
615
10
595
820
10
30
830
30
Front View Top View
555
525
Side View
31
30
555
10
10
525
15
code:
VIM201604/BVC/01
Page 17
16
code:
VIM201604/BVC/01
Page 18
V20BVCS3/BK
30
10
315 295
10
Front View
554
30
850
820
30
524
Side View
30
Top View
554
524
OPERATIONANOMALIES
Ensurethatthereispowertotheelectricalsupplyplugbyconnectinganotherelectrical appliancetoit.Checkfuse,ifany.Makesurethatthedoorisclosedproperly.
Ifyourbeveragecenterappearstobemalfunctioning,unplugitandcontactyour VINTECs aftersalesservice.Anyinterventiononthecoldcircuitshouldbeperformed byarefrigerationtechnicianwhoshouldcarryoutaninspectionofthecircuitsealing system.Similarly,anyinterventionontheelectricalcircuitshouldbeperformedbya qualifiedelectrician.
Notes: AnyinterventionperformedbyanonauthorizedtechniciansbyVintecwillleadto thewarrantybeingconsideredasnullandvoid.
POWERFAILURES
Intheeventofapowerinterruption,allprevioustemperaturesettingsareautomatically erasedanditwillreverttoapresettemperaturesetting.(seepresetchart)
Mostpowerfailuresarecorrectedwithinashortperiodoftime.Anhourortwoslossof powerwillnotaffectyourbeveragecentertemperatures.Toavoidsuddenchangeof temperaturewhilethepowerisoff,youshouldavoidopeningthedoor.Forlongerperiod ofpowerfailure,dotakestepstoprotectyourbeverage.
17
code:
VIM201604/BVC/01
Page 19
Irrespectiveofthecause,ifyounoticeeitherabnormaltemperatureorhumidity
The
circuit
breaker
tripped
or
the
fuse
is
broken.
The
door
gasket
does
not
seal
properly.
The
door
gasket
does
not
seal
properly.
The
light
button
is“OFF
.
Vibrations.
Check
to
assure
that
the
Beverage
Center
is
level.
levelsinsideyourbeveragecenter,bereassuredthatonlylongandfrequentexposure totheseabnormalconditionscancauseadetrimentaleffectonyourbeverage. TROUBLESHOOTINGGUIDE
Commonproblemsmayeasilybesolved,savingyouthecostofapossibleservicecall. Pleasereadcarefullytheinstructionmanualandreverttotroubleshootingguidechart.
PROBLEM POSSIBLECAUSE
Beveragecenterdoesnotoperate. Notpluggedin.
Theapplianceisturnedoff.
Beveragecenterisnotcoldenough. Checkthetemperaturecontrolsetting.
Externalenvironmentmayrequireahighersetting. Thedoorisopenedtoooften. Thedoorisnotclosedcompletely.
Turnsonandofffrequently. Theroomtemperatureishotterthannormal.
Alargeamountofcontentshasbeenaddedtothe Beveragecenter. Thedoorisopenedtoooften. Thedoorisnotclosedcompletely. Thetemperaturecontrolisnotsetcorrectly.
Thelightdoesnotwork. Notpluggedin.
Thecircuitbreakertrippedorablownfuse. Thelightisoutoforder.
TheBeveragecenterseemstomake toomuchnoise.
Therattlingnoisemaycomefromtheflowofthe refrigerant,whichisnormal. Aseachcycleends,youmayheargurglingsounds causedbytheflowofrefrigerantinyourBeverage center. Contractionandexpansionoftheinsidewallsmay causepoppingandcracklingnoises. TheBeverageCenterisnotlevel.
Thedoorwillnotcloseproperly. TheBeverageCenterisnotlevel.
Thedoorwasreversedandnotproperlyinstalled. Thegasketisfaulty.(magnetorrubberisspoiled) Theshelvesareoutofposition.
18
code:
VIM201604/BVC/01
Page 20
Technical
data
Models
Capacity
355
ml
Net
capacity
Gas
charge
quantity
Pre-set
temp
in
degrees
Adjustable
temp
in
degrees
Power
Input
Heater
Freestanding
or
Built-in
Nºof
shelf
Net
dim
in
mm
Gross
dim
in
mm
Net
weight
Gross
weight
AL/S3/BK
R600a
R600a
(R600a)
AL/S3/BK
R134a
S3/BK
(R600a)
140 74 54 140 53
146L 81.2L 57L 146L 56L
35g 30g 25g 70g 25g
5 5 5 5 5
2-10ºC 2-10ºC 2-10ºC 2-10ºC 2-10ºC
100W 85W 74W 140W 74W
(0)
-- -- -- -- --
Built-in Built-in Built-in Built-in Built-in
:(1)
3 3 3 3 3
Ambienttempindegrees 5-35ºC 5-35ºC 5-35 ºC 5-35ºC 5-35 ºC
595x572x820 380x572x820 300x592x810 595x572x820 295x561x820
(2)
655x665x875 415x625x845 335x640x840 655x665x875 340x630x860
44kg 34kg 28kg 44kg 28kg 48kg 38kg 31kg 48kg 31kg
REFRIGERANT
thesettemperature.
(0)
Unitswithnoheaterwillnotraiseitsinternaltemperatureiftheambienttemperaturewheretheunitislocatedislowerthanthesettemperature.
(1)
Subjecttochangesaccordinglytothevariousreferencesandmodelsmodifications.
(2)
Basedoncartonboxpackingdimensions/weight
Dimension: Actualappliancemeasurements,specificationsandratingsmayvaryslightlyduetotechnicalimprovementsandslightmanufacturingdifferences.
Whendimensionsarecriticalitisimportantthataneffectivecheckbemadeandtheaccompanyinginstructionsandinstallationmanualberead.
.
R600a R600a R600a R134a R600a
19
code: VIM201604/BVC/01
Page 21
Standardfeatures:
100V/50/60Hz,
220V/50/60Hz,115V/50Hz
-
Automatic
defrost
-
Humidi
ty:
65%
RH
+/-10%
RH
-
Black
outer
and
inner
finish
-
Internal
light
-
Adjustable
feetx4
-
Double
glass
door
with
3rd
acrylic
layer
-
Seamless
Stainless
Steel
door
frame
finish
for“S3”models
Compressoroperated:R600a
-Availableinratedvoltage/frequency(aspercountry'srequirements):
20
code: VIM201604/BVC/01
Page 22
Copyright:Allrightsarereserved.Allphotocopying,reproduction,translationwhetherpartialortotalarestrictlyprohibited, withoutpriorwrittenconsentfrom VINTEC.
www.vintec-cellar.com
code:
VIM201604/BVC/01
Loading...